  • Measuring principle

    Thermocouple

  • Characteristic / Application

    TA20J - SS - w. or w/o. display
    TMT142 - aluminium - fieldhousing w. or w/o. display
    TMT162 - aluminium - fieldhousing w. or w/o. display
    TMT162 - SS - fieldhousing w. or w/o. display
    Alu - screwed cover w. chain - E+H blue
    PP plastic - screwed cover w. chain
    TA30H - aluminum w. or w/o. display

  • Thermowell / protection tube

    to use with thermowell

  • Insert / probe

    mineral insulated (MI), flexible

  • Outer diameter protection tube / Insert

    1/4'' (6,35 mm)

  • Max. immersion length on request

    up to 30" (762 mm)
    others on request

  • Material protection tube/ thermowell

    Sensor sheath
    316
    Alloy 600

  • Optional coating

    not applicable

  • Process connection

    Thermowell connection
    male thread:
    NPT1/2"

  • Tip shape

    straight

  • Surface roughness Ra

    Not defined

  • Operating temperature range

    Type T:
    -270 °C ...370 °C
    (-454 °F ...698 °F)
    Type J:
    -210 °C ...720 °C
    (-346 °F ...1.328 °F)
    Type E:
    -270 °C ...820 °C
    (-454 °F ...1.508 °F)
    Type K:
    -270 °C ...1.150 °C
    (-454 °F ...2.102 °F)
    Type N:
    -270 °C ... 1.150 °C
    (-454 °F ...2.102 °F)

  • Max. process pressure (static)

    at 20 °C: 100 bar (1.450 psi)

  • Accuracy

    class 1 acc. to IEC 60584
    class 2 acc. to IEC 60584

  • Response time

    63% rt = 1,3 s

  • Integration head transmitter

    yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)

  • Ex - approvals

    transmitter only
    FM IS
    CSA IS
    FM/CSA IS

  • Certification

    SIL (transmitter only)