Prøv at søge efter nøgleord, ordre- eller produktkode eller serienummer, f.eks. “CM442” eller “Teknisk information”
Indtast mindst 2 tegn for at starte søgningen.
Source Container QG2000 - Radiometric measurement

Source container QG2000

QG2000
Please Wait (spinning wheel)
Indlæser pris
Priser er midlertidigt utilgængelige
Price on request
aktiverer pris
pris: information ønskes
from CHF ??.-
Filtrer måle- / anvendelsesopgave
Måle- / Anvendelsesopgave

Konfigurer for at downloade CAD-tegninger af dette produkt

  • Measuring principle

    Radiometric

  • Characteristic / Application

    Source container
    Emission angle: 40 / 20 degrees
    350kg

  • Specialities

    Control area calculation with Applicator

  • Ambient temperature

    -20 °C...+200 °C
    (-4 °F ... +392 °F)

  • Process temperature

    Any

  • Process pressure absolute / max. overpressure limit

    Any

  • Main wetted parts

    Non-contact

  • Process connection

    Non-contact

  • Successor

    FQG66

  • Measuring principle

    Radiometric

  • Characteristic / Application

    Source container
    Emission angle: 5 degrees
    350kg

  • Specialities

    Control area calculation with Applicator

  • Ambient temperature

    -20 °C...+200 °C
    (-4 °F...+392 °F)

  • Process temperature

    Any

  • Process pressure absolute / max. overpressure limit

    Any

  • Main wetted parts

    Non- contact

  • Process connection

    Non- contact

  • Process connection hygienic

    Non- contact

  • Successor

    FQG66

  • Measuring principle

    Radiometric

  • Characteristic / Application

    Source container
    Emission angle: 20/ 40 degrees
    350kg

  • Ambient temperature

    -20 °C...+200 °C

  • Process temperature

    Any

  • Process pressure absolute

    Any

  • Wetted parts

    Non-contact

  • Hygienic

    Non-contact

  • Specialities

    Control area calculation with Applicator

  • Successor

    FQG66

  • Measuring principle

    Radiometric

  • Characteristic / Application

    Source container
    Emission angle: 5 degrees
    350kg

  • Specialities

    Control area calculation with Applicator

  • Ambient temperature

    -20 °C...+200 °C
    (-4 °F...+392 °F)

  • Process temperature

    Any

  • Process pressure absolute / max. overpressure limit

    Any

  • Main wetted parts

    Non- contact

  • Process connection hygienic

    Non- contact

  • Successor

    FQG66

  • Measuring principle

    Radiometric

  • Characteristic / Application

    Source container
    Emission angle: 40 / 20 degrees
    350kg

  • Specialities

    Control area calculation with Applicator

  • Ambient temperature

    -20 °C...+200 °C
    (-4 °F...+392 °F)

  • Process temperature

    Any

  • Process pressure absolute / max. overpressure limit

    Any

  • Main wetted parts

    Non-contact

  • Process connection

    Non-contact

  • Successor

    FQG66