Prøv at søge efter nøgleord, ordre- eller produktkode eller serienummer, f.eks. “CM442” eller “Teknisk information”
Indtast mindst 2 tegn for at starte søgningen.
Prosonic FDU93 - Ultrasonic measurement

Ultrasonic measurement
Time-of-Flight
Prosonic FDU93

Ultrasonic sensor for level and flow measurement for connection to FMU9x (measuring range up to 25m)

FDU93
Please Wait (spinning wheel)
Indlæser pris
Priser er midlertidigt utilgængelige
Price on request
aktiverer pris
pris: information ønskes
from CHF ??.-
Filtrer måle- / anvendelsesopgave
Måle- / Anvendelsesopgave

Konfigurer for at downloade CAD-tegninger af dette produkt

  • Measuring principle

    Ultrasonic

  • Characteristic / Application

    Separated version with field housing or top hat rail housing for control cabinet instrumentation, 300 m in-between sensor and transmitter

  • Supply / Communication

    4-wire (HART, Profibus DP)

  • Accuracy

    +/- 2 mm + 0.17% of measured distance

  • Ambient temperature

    -40 °C ... 95 °C
    (-40 °F ... 203 °F)

  • Process temperature

    -40 °C ... 95 °C
    (-40 °F ... 203 °F)

  • Process pressure / max. overpressure limit

    0.7 bar ... 3 bar abs
    (10 psi ... 43 psi)

  • Main wetted parts

    UP (unsaturated polyester)
    Silicon / Al PTFE coated

  • Process connection

    G / NPT 1"

  • Blocking distance

    0.6 m (2 ft)

  • Max. measurement distance

    Liquids: 25 m (85 ft),
    Solids: 15 m (50 ft)

  • Communication

    Transmitter:
    4...20 mA HART
    Profibus DP

  • Certificates / Approvals

    ATEX, FM, CSA, IEC Ex, INMETRO, NEPSI, EAC Ex

  • Options

    Second 4...20 mA output

  • Components

    Transmitter:
    FMU90, FMU95

  • Application limits

    For tank farms scanner:
    FMU95

  • Measuring principle

    Ultrasonic

  • Characteristic / Application

    Separated version with field housing or top hat rail housing for control cabinet instrumentation, 300m in-between sensor and transmitter

  • Supply / Communication

    4-wire (HART , Profibus DP)

  • Accuracy

    +/- 2mm + 0.17% of measured distance

  • Ambient temperature

    -40 °C ... 95 °C
    (-40 °F ... 203 °F)

  • Process temperature

    -40 °C ... 95 °C
    (-40 °F ... 203 °F)

  • Process pressure / max. overpressure limit

    0.7 bar ... 3 bar abs
    (10 psi ... 43 psi)

  • Main wetted parts

    UP (unsaturated polyester)
    Silicon / Al PTFE coated

  • Process connection

    G / NPT 1"

  • Blocking distance

    0.6 m (2 ft)

  • Max. measurement distance

    Liquids: 25 m (85 ft),
    Solids: 15 m (50 ft)

  • Communication

    Transmitter:
    4 ... 20 mA HART
    Profibus DP

  • Certificates / Approvals

    ATEX, FM, CSA, IEC Ex, INMETRO, NEPSI, EAC Ex

  • Options

    Second 4...20mA output

  • Components

    Transmitter:
    FMU90