Oversigt over specifikationer
-
Max. measurement error
Volume flow:
±3% o.r. for DN15
±2% o.r. for DN25 to 200
±2% o.r. above DN200 -
Measuring range
0.3 to 10 m/s (1 to 33 ft/s)
-
Medium temperature range
-20 to +80°C (-4 to +176 °F)
0 to +130°C (32 to +265 °F) option -
Max. process pressure
N/A
-
Wetted materials
Clamp on system:
Sensor holder 1.4308/CF-8
Sensor housing 1.4301/304
Strapping bands 1.4301/304
Anvendelsesområde
The Prosonic Flow W clamp-on sensor is specially designed for water and wastewater applications. Combined with the cost-effective Prosonic Flow 91 transmitter with push buttons, Prosonic Flow 91W is ideally suited for flow monitoring in the water industry.
The measuring principle is independent of pressure, density, temperature, conductivity and viscosity
Clamp-on flow measurement of process water, salt water, deminerialized water, drinking & wastewater.
Device properties:
Medium temperature: –20 to +80 °C (-4 to +176 °F)
Degree of protection IP68 (Type 6P enclosure) for pipes under water
Shock and vibration resistance according to IEC 68-2-6
Aluminium field transmitter housing
2-line display with push buttons
HART
Fordele
Low capital investment – cost-effectiveness increases with pipe diameter (up to DN 2000)
Long-term stable signal - maintenance-free permanent mounting from outside with coupling pads
Process transparency – diagnostic capability
Economical transmitter – designed for easy applications
Fast and reliable commissioning – Quick Setup menu for installation
Automatic recovery of data for servicing
Videoer
Forgænger
-
Standardprodukter
- Pålidelige og robuste med lav vedligeholdelse
Teknisk ydeevne
Enkelhed
-
Specialiserede produkter
- Designet til krævende applikationer
Teknisk ydeevne
Enkelhed
Variabel
FLEX valg | Teknisk ydeevne | Enkelhed |
---|---|---|
Fundamental Få dækket dine basale målebehov |
Teknisk ydeevne
|
Enkelhed
|
Lean Administrer nemt dine kerneprocesser |
Teknisk ydeevne
|
Enkelhed
|
Extended Optimer dine processer med innovative teknologier |
Teknisk ydeevne
|
Enkelhed
|
Xpert Til de mest udfordrende applikationer |
Teknisk ydeevne
|
Enkelhed
Variabel |
-
-
Tekniske oplysninger (TI)
Proline Prosonic 91W Technical Information
Engelsk version - 12/2023
Ultrasonic Flow Measuring System Flowrate measurement for standard applications with drinking water and process water.
EN DA 06/12/202319/08/201101/02/2010Sprog:
Engelsk
Version:
06/12/2023
Filstørrelse:
1.8 MB
Filnavn:
TI00105DEN_1423.pdf
-
-
-
Betjeningsvejledning (BA)
Prosonic Flow 91 Operating Instructions
Engelsk version - 12/2023
Ultrasonic Flow Measuring System Flow rate measuring for standard applications with drinking water, wastewater and process water (incl. Description of Device Functions)
EN DA 06/12/202319/08/201101/02/201001/04/2006Sprog:
Engelsk
Version:
06/12/2023
Filstørrelse:
5.4 MB
Filnavn:
BA00100DEN_1423.pdf
-
-
-
Tekniske oplysninger (TI)
Proline Prosonic 91W Technical Information
Ultrasonic Flow Measuring System
Flowrate measurement for standard applications with
drinking water and process water.EN DA 06/12/202319/08/201101/02/2010Sprog:
Engelsk
Version:
06/12/2023
Filstørrelse:
1.8 MB
Filnavn:
TI00105DEN_1423.pdf
-
-
-
Tekniske oplysninger (TI)
Prosonic Flow 90U, 90W, 91W, 93C, 93U, 93W Technical Information (SI units)
Ultrasonic Flow Measuring System
Volume Flow Measurement for Standard Applications with Water, Wastewater
and Process WaterEN DA 01/04/200601/05/200515/10/200301/12/2002Sprog:
Engelsk
Version:
01/04/2006
Filstørrelse:
1.4 MB
Filnavn:
TI057DEN.pdf
-
-
-
Betjeningsvejledning (BA)
Prosonic Flow 91 Operating Instructions
Ultrasonic Flow Measuring System
Flow rate measuring for
standard applications with
drinking water, wastewater and
process water
(incl. Description of Device Functions)EN DA 06/12/202319/08/201101/02/201001/04/2006Sprog:
Engelsk
Version:
06/12/2023
Filstørrelse:
5.4 MB
Filnavn:
BA00100DEN_1423.pdf
-
-
-
Kort anvisning (KA)
Proline Prosonic Flow 90, 91, 93 Sonderdokumentation / Special Documentation
Montageanleitung für die Verbindung Sensoren / Messumformer bei
Verwendung von flexiblen Kabelschutzrohren
Mounting instruc
tions for the sensor / transmitter connection using flxible conduitEN DA 01/11/2006Sprog:
Engelsk
Version:
01/11/2006
Filstørrelse:
228.6 KB
Filnavn:
KA015Da2.pdf
-
-
-
Kort anvisning (KA)
Proline Prosonic Flow 91W Brief Operating Instructions
Ultrasonic flow measuring system
EN DA 13/02/201219/08/201126/04/2010Sprog:
Engelsk
Version:
13/02/2012
Filstørrelse:
976.4 KB
Filnavn:
KA00049DEN_1412.pdf
-
-
-
Installationsanvisninger (EA)
Safety Instructions for Spare Parts Installation Instructions
Flowmeter
EN DA 01/03/201828/11/201325/04/2013Sprog:
Engelsk
Version:
01/03/2018
Filstørrelse:
139.5 KB
Filnavn:
EA01051DA2_0318.pdf
-
-
-
Installationsanvisninger (EA)
Replacing T-DAT Installation Instructions
Promag 23, 53, 55, Promass 83, 84, 8WF, 8ME, Cubemass DCI 8CN, CNGmass
DCI 8DF, Prosonic Flow 91, 93, t-mass 65EN DA 15/11/201821/11/2011Sprog:
Engelsk
Version:
15/11/2018
Filstørrelse:
481.6 KB
Filnavn:
EA00072DA2_1418.pdf
-
-
-
Installationsanvisninger (EA)
Replacing cover and O-ring Installation Instructions
romag 10, 23, 50, 51, 53, 55, 400, 800, Promass 40, 80, 83, 84, 8ME,
CNGmass 8FF, LPGmass 8FE, Cubemass 8CM, Prosonic Flow 90, 91,9
2, 93, t-mass 65, Prowirl 72, 73EN DA 01/10/201828/06/2012Sprog:
Engelsk
Version:
01/10/2018
Filstørrelse:
520.1 KB
Filnavn:
EA00098DA2_1518.pdf
-
-
-
Installationsanvisninger (EA)
EA Permanent Coupling Pad
Prosonic Flow 91W, 93P, W 400, P 500
EN DA 01/03/202415/12/202101/08/202116/09/2019Sprog:
Engelsk
Version:
01/03/2024
Filstørrelse:
609.4 KB
Filnavn:
EA01256DA2_0423-00.pdf
-
-
-
Installationsanvisninger (EA)
Replacing transmitter parts Installation Instructions
Promag 10, Prosonic Flow 91 W
EN DA 01/04/201917/11/2011Sprog:
Engelsk
Version:
01/04/2019
Filstørrelse:
558.9 KB
Filnavn:
EA00040DA2_1419.pdf
-
-
-
Specialdokumentation (SD)
Change of Directives Special Documentation
Change of Directives
EN DA 20/04/2016Sprog:
Engelsk
Version:
20/04/2016
Filstørrelse:
52.2 KB
Filnavn:
SD01764DEN_0116.pdf
-
-
-
Producentoplysninger (MI)
Proline Prosonic Flow 91 Manufacturer information regarding software updates (NE 53)
New software version:
Prosonic Flow 91 HART: 1.00.02EN DA 01/01/2007Sprog:
Engelsk
Version:
01/01/2007
Filstørrelse:
145.2 KB
Filnavn:
MI00013D_06_en_01.07.pdf
-
-
-
Producentoplysninger (MI)
Proline Prosonic Flow 91 Manufacturer information regarding software updates (NE 53)
New software version:
Prosonic Flow 91 HART: 1.00.03EN DA 01/05/2009Sprog:
Engelsk
Version:
01/05/2009
Filstørrelse:
144.4 KB
Filnavn:
MI00033D_06_en_05.09.pdf
-
-
-
Producentoplysninger (MI)
Proline Prosonic Flow 91 Manufacturer information regarding software updates (NE 53)
New software version:
Prosonic Flow 91 HART: 1.01.00EN DA 01/01/2010Sprog:
Engelsk
Version:
01/01/2010
Filstørrelse:
144.5 KB
Filnavn:
MI00042D_06_en_01.10.pdf
-
-
-
Producentoplysninger (MI)
Proline Prosonic Flow 91 Manufacturer information regarding software updates (NE 53)
New software version:
Prosonic Flow 91 HART: 1.02.00EN DA 01/04/2011Sprog:
Engelsk
Version:
01/04/2011
Filstørrelse:
145.4 KB
Filnavn:
MI01088D_06_en_04.11.pdf
-
-
-
Kompetencebrochure (CP)
Ultraschall-Durchflussmessung von außen: Kostengünstig – flexibel – robust
Clamp-on-Messtechnologie
KompetenzbroschüreSprog:
Tysk
Version:
01/05/2010
Filstørrelse:
3 MB
Filnavn:
CP015DDE_0510.pdf
-
-
-
Kompetencebrochure (CP)
Flow measurement from outside the pipe: Cost-effective – flexible – robust
Ultrasonic clamp-on technology
Competence brochureSprog:
Engelsk
Version:
01/05/2010
Filstørrelse:
3 MB
Filnavn:
CP015DEN_0510.pdf
-
-
-
Casestudie (CS)
Optimierung der Energieeffizienz
Erfassung und Analyse des Heizwärmebedarfs im Schulhaus Ettingen
Sprog:
Tysk
Version:
24/02/2020
Filstørrelse:
933.1 KB
Filnavn:
CS01629S_20_DE0120_Gemeinde Ettingen.pdf
-
-
-
Casestudie (CS)
Water for irrigation (clamp-on ultrasonic flow measurement)
Transforming 100000 hectares of arid land into fertile agricultural land
with the potential to support around 20 000 farmersSprog:
Engelsk
Version:
30/07/2012
Filstørrelse:
286.6 KB
Filnavn:
CS01304DEN_0112.pdf
-
-
-
Casestudie (CS)
Energieeffizienzoptimierung
Erfassung und Analyse des Heiz-
wärmebedarfsim Schulhaus
EttingenSprog:
Tysk
Version:
02/08/2021
Filstørrelse:
935.6 KB
Filnavn:
CS01710S_20_DE0120_Gemeinde_Ettingen.pdf
-