Absolute and
gauge pressure
Cerabar PMC71

Cerabar PMC71 aluminum housing ©Endress+Hauser
Cerabar PMC71 aluminum housing ©Endress+Hauser
Cerabar PMC71 flange ©Endress+Hauser
Cerabar PMC71 hygienic housing ©Endress+Hauser

Pressure measuring principle

Cerabar PMC71 with manifolds ©Endress+Hauser

Digital pressure transmitter with oil-free ceramic sensor for measurement in gases or liquids

The Cerabar PMC71 digital pressure transmitter with capacitive, oil-free ceramic measuring cell is typically used in the process and hygienic applications for pressure, level, volume or mass measurement in liquids and gases. It guarantees high degree of system safety thanks to vacuum-proof ceramic membrane with integrated breakage detection. Quick Setup with adjustable measuring range allows simple commissioning, reduces costs and saves time. SIL2/3 according to IEC 61508.

  • Fordele

    • Best fit for vacuum applications and applications with corrosive and abrasive media

    • Process safety through membrane breakage detection

    • Overload-resistant high purity ceramic sensor (99.9% Al2O3)

    • HistoROM data management concept for fast and easy...

  • Anvendelsesområde

    Two chamber aluminum or stainless steel (316L) housing.

    • Process connections: Threads, flanges or hygienic connections

    • Process temperature: -40 to +150°C (-40 to +302°F)

    • Measuring ranges: -1/0 up to to +40bar (+1.5 to +600psi)

    • Accuracy: ±0.05%, "...

Funktioner og specifikationer

Tilbage

Details

  • Measuring principle

    Absolute and gauge pressure

  • Characteristic / Application

    Digital transmitter with capacitive sensor and ceramic membrane
    Modular transmitter
    Long term stability
    Enhanced safety via self diagnostic functions
    Secondary process barrier

  • Specialities

    diagnostic functionalities

    different languages in software

  • Supply / Communication

    4...20mA HART:
    10,5...45V DC
    Ex ia: 10,5...30V DC
    PROFIBUS PA /
    FOUNDATION Fieldbus:
    9...32V DC

  • Accuracy

    0,075%
    "PLATINUM" 0,05%

  • Long term stability

    0,05% of URL/year

  • Ambient temperature

    -40°C...85°C
    (-40°F...185°F)

  • Process temperature

    -40°C...150°C
    (-40°F...302°F)

  • Process pressure absolute / max. overpressure limit

    60bar (900psi)

  • Pressure measuring range

    100mbar...40bar
    (1.5psi...600psi)

  • Main wetted parts

    Ceraphire ceramic
    Alloy C
    316L
    Monel
    PVDF

  • Process connection

    Threads
    Flanges
    Tri-Clamp ISO2852
    Hygienic connections

  • Max. measurement distance

    400m (1312ft) H2O

  • Communication

    4 ... 20 mA HART

    PROFIBUS PA

    FOUNDATION Fieldbus

  • Certificates / Approvals

    ATEX, FM, CSA C/US, IEC Ex, JPN Ex, INMETRO, NEPSI, EAC

  • Safety approvals

    Overfill prevention WHG

    SIL

  • Design approvals

    EN 10204-3.1

  • Marine approval

    GL/ ABS

  • Drinking water approvals

    NSF

  • Options

    HistoROM/M-Dat
    4-line digital display
    SS- or Aluminiumhousing
    Separate housing

  • Application limits

    Measuring cell: ceramics

    If pressurized, possibly
    use differential pressure
    measurement with two
    pressure transmitters
    (electronic dp). Observe
    ratio head pressure :
    hydrostatic pressure

  • Measuring principle

    Absolute and gauge pressure

  • Characteristic

    Digital transmitter with capacitive sensor and ceramic membrane
    Modular transmitter
    Long term stability
    Enhanced safety via self diagnostic functions
    Secondary process barrier

  • Supply voltage

    4...20 mA HART

    10,5...45V DC (Non Ex):

    Ex ia: 10,5...30V DC

    PROFIBUS PA:

    9...32 V DC (Non Ex)

    FOUNDATION Fieldbus:

    9...32 V DC (Non Ex)

  • Reference Accuracy

    Standard: 0.05%

    Platinum: up to 0.025%

  • Long term stability

    0,05% of URL/year

  • Process temperature

    -20°C...150°C
    (-4°F...257°F)

  • Ambient temperature

    -40°C...85°C
    (-40°F...185°F)

  • Measuring cell

    100 mbar...40 bar
    (1.5 psi...600 psi)

    relative/ absolute

  • Smallest calibratable span

    5 mbar (0.075 psi)

  • Vacuum resistance

    0 mbar abs.

  • Max. Turn down

    100:1

  • Max. overpressure limit

    60 bar (900 psi)

  • Process connection

    Thread:

    G1/2...G2, R1/2, MNPT1/2...MNPT2

    Flange:

    DN25...DN80,

    ASME 1"...4",

    JIS 10K

  • Process connection hygienic

    Tri-Clamp

    DIN11851

    Varivent N

    SMS

    DRD

  • Material process membrane

    Ceramic

  • Material gasket

    Viton, EPDM, Chemraz, Kalrez, NBR

  • Fill fluid

    none, dry measuring cell

  • Material housing

    Die-cast aluminum,

    AISI 316L

  • Communication

    4...20 mA HART
    PROFIBUS PA
    FOUNDATION Fieldbus

  • Certificates / Approvals

    ATEX, FM, CSA, CSA C/US, IEC Ex, JPN Ex, INMETRO, NEPSI, EAC

  • Safety approvals

    Overfill prevention WHG

    SIL

  • Design approvals

    EN10204-3.1

  • Hygienic approvals

    3A, EHEDG

  • Marine approvals

    GL/ ABS

  • Drinking water approvals

    NSF

  • Specialities

    Diagnostic functions

Dokumenter / Vejledninger / Software

Tilbehør / Reservedele

Nr
Order code
Specification
  • 12
    • Nr 12 Order code 52020440

      Mounting set housing T14/T15 / sensor

      Consists of: 2x O-ring 45.69x2.62 EPDM. Retaining ring, plastics. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 12 Order code 71020596

      Mounting set housing T17 / sensor

      Consists of: 2x O-ring 45.62x69x2.62 EPDM. 1x profile gasket 51.4x57.2x1.6 EPDM. Retaining ring, plastics. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

  • 13
    • Nr 13 Order code 52022418

      Push button housing, PA/FF

      Consists of: push button, cover + screws. Usage: external operation, FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 13 Order code 52022419

      Push button housing, HART, version 1

      Consists of: push button, cover + screws. Colour light grey. Usage: external operation, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 13 Order code 52024110

      Push button housing, HART, version 2

      Consists of: push button, cover + screws. Colour dark grey. Usage: external operation, FMB70, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75.

  • 15
    • Nr 15 Order code 52020760

      Cable gland M20, gasket

      Consists of: cable gland M20. O-ring 18.72x2.62 VMQ. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 15 Order code 52020761

      Cable entry G1/2, gasket, adapter

      Consists of: gasket 18.72x2.51 NBR. Adapter M20 > G1/2. O-ring 18.77x1.78 NBR. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 15 Order code 52020762

      Plug 2/7-pole, HAN7D, gasket

      Consists of: harting plug set. Usage: FMB50/FMB51/FMB52/FMB53, FMB70, FMD76/FMD77/FMD78, PMC51, PMC71, PMD55, PMD70/PMD75, PMP51/PMP55, PMP71/PMP75.

    • Nr 15 Order code 52020763

      Plug 3-pole, M12, gasket

      Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Order code 71111056

      Housing filter VA,EPDM,F15/31/T14/17,1pc

      Consists of: vent screw 304. Pressure compensation filter. O-ring EPDM, protection lid. Usage: housing T14, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75. Housing F31, FMB50/FMB51/FMB52/FMB53, PMC51, PMP51/PMP55. Housing F15 w/o B1,BB,BD,BF,GA,ID,I1, FMB50/FMB51/FMB52/FMB53, PMC51, PMP51/PMP55.

    • Order code 71219639

      Housing filter VA, VMQ, F15, T17, 1 pc.

      Consists of: vent screw 304. Pressure compensation filter. O-ring VMQ, protection lid. Usage: housing T17, FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/ PMP75. Housing F15 bei B1,BB,BD,BF,GA,ID,I1, FMB50/FMB51/FMB52/FMB53, PMC51, PMP51/PMP55.

  • 20
    • Nr 20 Order code 52020432

      Cover T14/T15 Alu, gasket

      Material: aluminium, coated. O-ring EPDM, FDA. Not for EEx d/XP. Usage: FMB70, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 20 Order code 52020433

      Cover T14/T15 Alu, Ex d, gasket

      Material: aluminium, coated. O-ring EPDM, FDA. EEx d/XP. Usage: FMB70, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 20 Order code 52028310

      Cover T14 316L, Ex d, EPDM

      Material: 316L. O-ring EPDM, FDA. Individual tested, EEx d/XP. Usage: FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 20 Order code 71002774

      Cover T17 316L, gasket

      Material: 316L. Flat gasket EPDM, centering ring, screw. Not for EEx d/XP. Usage: FMB70, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 20 Order code 71002810

      Cover T17 316L, sight glass, gasket

      Material: 316L. Sight glass: mineral glass. Flat gasket EPDM, centering ring, screw. For approval 2,3,4,7,8,Q,W. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75. For approval BC,BD,IB. Usage: FMD71/FMD72.

    • Nr 20 Order code 71002811

      Cover T17 316L, sight glass PC, gasket

      Material: 316L. Sight glass: Polycarbonate PC. Flat gasket EPDM, centering ring, screw. For approval A,E,F,H,I,R,S,U,1,6. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75. For approval AA,BA,CA,CB,CC,CD,FA,FB, FD,IA. Usage: FMD71/FMD72.

    • Nr 20 Order code 71245247

      Cover T14/T15 Alu, sight glass, gasket

      Material: aluminium, coated. Sight glass: mineral glass, coated. O-ring EPDM, FDA. Not for EEx d/XP. Usage: FMB70, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 20 Order code 71245249

      Cover T14/T15 Alu,Exd,sight glass,gasket

      Material: aluminium. Sight glass mineral glass, coated. O-ring EPDM, FDA. Individual tested, EEx d/XP. Usage: FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

  • 21
    • Nr 21 Order code 52020429

      Sealing EPDM, F30/31/34, T14/15, 5 pcs.

      Consists of: 5x O-ring 75.87x2.62, EPDM, PTFE, FDA. Usage: housing F30/F31/F34, T14/T15.

    • Nr 21 Order code 71206971

      Sealing set FVQM, T14.5 pcs.

      Consists of: 5x O-ring 75.87x2.62 FVMQ. Usage: housing T14, FMD77/FMD78, PMD70/PMD75, PMP71/PMP75.

    • Order code 71043886

      Cable PE, L=2m/80inch, separate housing

      Connection cable sensor>sep. housing. Usage: FMB50/FMB51/FMB52, FMB70, FMD76/FMD77/FMD78, PMC51, PMC71, PMD70/PMD75, PMP51/PMP55, PMP71/PMP75.

    • Order code 71043888

      Cable PE, L=5m/200inch, separate housing

      Connection cable sensor>sep. housing. Usage: FMB50/FMB51/FMB52, FMB70, FMD76/FMD77/FMD78, PMC51, PMC71, PMD70/PMD75, PMP51/PMP55, PMP71/PMP75.

    • Order code 71043889

      Cable PE, L=10m/400inch,separate housing

      Connection cable sensor>sep. housing. Usage: FMB50/FMB51/FMB52, FMB70, FMD76/FMD77/FMD78, PMC51, PMC71, PMD70/PMD75, PMP51/PMP55, PMP71/PMP75.

    • Order code 71070738

      Cable FEP, L=5m/200inch,separate housing

      Connection cable sensor>sep. housing. Usage: FMB50/FMB51/FMB52, FMB70, FMD76/FMD77/FMD78, PMC51, PMC71, PMD70/PMD75, PMP51/PMP55, PMP71/PMP75.

    • Order code 71290825

      Ground terminal T14/T15/T17, F30/F31

      Consists of: spring washer, screw, earth handle, clamp. Usage: housing T14/T15/T17, FMB70, FMD71/FMD72/ FMD77/FMD78, PMC71, PMP71/PMP75, PMD70/PMD75. Housing F30/F31, FMB50/FMB51/FMB52/ FMB53, PMC51, PMD55, PMP51/PMP55.

  • 25
    • Nr 25 Order code 52020432

      Cover T14/T15 Alu, gasket

      Material: aluminium, coated. O-ring EPDM, FDA. Not for EEx d/XP. Usage: FMB70, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 25 Order code 52020433

      Cover T14/T15 Alu, Ex d, gasket

      Material: aluminium, coated. O-ring EPDM, FDA. EEx d/XP. Usage: FMB70, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 25 Order code 52028310

      Cover T14 316L, Ex d, EPDM

      Material: 316L. O-ring EPDM, FDA. Individual tested, EEx d/XP. Usage: FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 25 Order code 71002774

      Cover T17 316L, gasket

      Material: 316L. Flat gasket EPDM, centering ring, screw. Not for EEx d/XP. Usage: FMB70, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

  • 20
    • Nr 20 Order code 71206965

      Cover T14 316L, Ex d, FVMQ

      Material: 316L. O-ring FVMQ. Individual tested, EEx d/XP. Usage: FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP72/PMP75.

    • Nr 20 Order code 71206968

      Cover T14 316L, Ex d, sight glass, FVMQ

      Material: 316L. Sight glass: mineral glass,coated. O-ring FVMQ. Individual tested, EEx d/XP. Usage: FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 20 Order code 71245250

      Cover T14 316L, Ex d, sight glass, EPDM

      Material: 316L. Sight glass: mineral glass, coated. O-ring EPDM, FDA. Individual tested, EEx d/XP. Usage: FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

  • 25
    • Nr 25 Order code 71206965

      Cover T14 316L, Ex d, FVMQ

      Material: 316L. O-ring FVMQ. Individual tested, EEx d/XP. Usage: FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP72/PMP75.

  • 30
    • Nr 30 Order code 52024111

      Electronics HART Ex, ext. p. b., v2.0

      4-20mA, version 2.0. Push button on housing. Usage: FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 30 Order code 52024400

      Electronics HART Ex, v2.0

      4-20mA, version 2.0. Push button on electronics. Usage: FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 30 Order code 71026358

      Electronics HART Ex, v2.10

      4-20mA, version 02.10.zz. Push button on electronics. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 30 Order code 71026359

      Electronics HART Ex, ext. p. b., v2.10

      4-20mA, version 02.10.zz. Push button on housing. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 30 Order code 71196092

      Electronic HART Ex, v2.11

      4-20mA, version 02.11.zz. Push button on electronics. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75. Not for MID parts certificate (PMP71).

    • Nr 30 Order code 71196093

      Electronics HART Ex, ext. p. b., v2.11

      4-20mA, version 2.11.zz. Push button on housing. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75. Not for MID parts certificate (PMP71).

    • Order code 52026762

      Upgrade electronics HART Ex, v2.1

      Consists of: electronics HART Ex, version 2.1. Push button on electronics. Display housing. Usage: conversion electronics 1.0 > 2.1, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Order code 52026763

      Upgrade electr. HART Ex,ext.push b.,v2.1

      Consists of: electronics HART Ex, version 2.1. Push button external. Push button, housing HART version 2. Display housing. Usage: conversion electronics 1.0 > 2.1, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

  • 30
    • Nr 30 Order code 71071824

      Electronics PA, HW02.00, SW4.0

      PROFIBUS PA, Ex. Hardware version 02.00. Software version 04.00.zz. Current consumption 13mA +/-1mA. Push button on electronics. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 30 Order code 71071825

      Electronics PA, ext. p.b., HW02.00,SW4.0

      PROFIBUS PA, Ex. Hardware version 02.00. Software version 04.00.zz. Current consumption 13mA +/-1mA. Push button on housing. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 30 Order code 71071826

      Electronics FF, HW2.00, SW3.00

      FOUNDATION Fieldbus, Ex. Hardware version 02.00. Software version 03.00.zz. Current consumption 15mA +/- 1mA. Push button on electronics. Verwendung: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 30 Order code 71071827

      Electronics FF, ext. p.b., HW2.00,SW3.00

      FOUNDATION Fieldbus, Ex. Hardware version 02.00. Software version 03.00.zz. Current consumption 15mA +/- 1mA. Push button on housing. Verwendung: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 30 Order code 71214057

      Electronics PA, Ex, HW2.00, SW3.00

      PROFIBUS PA, Ex. Hardware version 02.00. Software version 03.00.zz. Current consumption 13mA +/-1mA. Push button on electronics. Usage: FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 30 Order code 71214064

      Electronics PA, ext. p.b.,HW2.00, SW3.00

      PROFIBUS PA, Ex. Hardware version 02.00. Software version 03.00.zz. Current consumption 13mA +/-1mA. Push button on housing. Usage: FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 30 Order code 71214066

      Electronics FF, ext. p.b.,HW2.00, SW2.00

      FOUNDATION Fieldbus, Ex. Hardware version 02.00. Software version 02.00.zz. Current consumption 15mA +/-1mA. Push button on housing. Usage: FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 30 Order code 71214069

      Electronics FF, HW2.00, SW2.00

      FOUNDATION Fieldbus, Ex. Hardware version 02.00. Software version 02.00.zz. Current consumption 15mA +/-1mA. Push button on electronics. Usage: FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 30 Order code 71214890

      Electronics FF, ext. p.b.,HW2.00, SW4.00

      FOUNDATION Fieldbus, Ex. Hardware version 02.00. Software version 04.00.zz, FF, DevRev07. Current consumption 15mA +/-1mA. Push button on housing. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75. Not for SIL.

    • Nr 30 Order code 71214892

      Electronics FF, HW2.00, SW4.00

      FOUNDATION Fieldbus, Ex. Hardware version 02.00. Software version 04.00.zz, FF, DevRev07. Current consumption 15mA +/-1mA. Push button on electronics. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75. Not for SIL.

    • Nr 30 Order code 71224775

      Electronics PA, HW02.00, SW4.01

      PROFIBUS PA, Ex. Hardware version 02.00. Software version 04.01.zz, PROFIBUS PA, Profile 3.02, DevRev03. Current consumption 13mA +/-1mA. Push button on electronics. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 30 Order code 71224776

      Electronics PA, ext.p. b.,HW02.00,SW4.01

      PROFIBUS PA, Ex. Hardware version 02.00. Software version 04.01.zz, PROFIBUS PA, Profile 3.02, DevRev03. Current consumption 13mA +/-1mA. Push button on housing. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 30 Order code 71263933

      Electronics HART Ex, v2.20

      4-20mA. Software version 02.20.zz, HART 7, DevRev22. Push button on electronics. Usage: FMB70, FMD77/FMD78, PMC71, PMD75, PMP71/PMP75. Not for MID parts certificate (PMP71).

    • Nr 30 Order code 71263934

      Electronics HART Ex, ext. p. b., v2.20

      4-20mA. Software version 02.20.zz, HART 7, DevRev22. Push button on housing. Usage: FMB70, FMD77/FMD78, PMC71, PMD75, PMP71/PMP75. Not for MID parts certificate (PMP71).

    • Nr 30 Order code 71386147

      Elektronics HART Ex, v2.30

      4-20mA. Software version 02.30.zz, HART 7, DevRev23. Push button on electronics. Usage: FMB70, FMD77/FMD78, PMC71, PMD75, PMP71/PMP75. Not for MID parts certificate (PMP71).

  • 31
    • Nr 31 Order code 52027785

      HistoROM / M-DAT, 16K

      Setup-/diagnostic software included. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

  • 35
    • Nr 35 Order code 52020434

      Terminal 3-pole, RFI, HART, TIIS

      RFI-filter. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75, TIIS Ex ia.

    • Nr 35 Order code 52020436

      Terminal PMC71, 3-pole, RFI, HART, Ex d

      RFI-filter. Usage: PMC71. Only for TIIS Ex d.

    • Nr 35 Order code 52026605

      Terminal 2-pole, RFI, PA, TIIS

      RFI filter. PROFIBUS PA. Usage: FMB70, FMD76/FMD77/FMD78, PMD70/PMD75, PMP71/PMP75. TIIS Ex ia, TIIS Ex d. PMC71, TIIS Ex ia.

    • Nr 35 Order code 52026606

      Terminal PMC71, 2-pole, RFI, PA, Ex d

      RFI filter. PROFIBUS PA. Usage: PMC71, TIIS Ex d.

    • Nr 35 Order code 52027691

      Terminal 2-pole, RFI, FF, Ex

      RFI-filter. FOUNDATION Fieldbus. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 35 Order code 52027692

      Terminal PMC71, 2-pole, RFI, FF, Ex d

      RFI-filter. FOUNDATION Fieldbus. Usage: PMC71.

    • Nr 35 Order code 71028475

      Terminal 2-pole, RFI, PA, OVP, Ex

      Overvoltage protection, RFI-filter. PROFIBUS PA. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 35 Order code 71028476

      Terminal 2-pole, RFI, FF, OVP, Ex

      Overvoltage protection, RFI-filter. FOUNDATION Fieldbus. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 35 Order code 71121574

      Terminal 2-pole, RFI, PA, Ex

      RFI filter. PROFIBUS PA. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75. Not for TIIS.

    • Nr 35 Order code 71191892

      Terminal 3-pole,Li=0, RFI,HART,Ex ia/Exd

      RFI-filter. Not for TIIS Ex ia, TIIS Ex d. Usage: FMB70, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 35 Order code 71191894

      Termin.3-p.,Li=0,RFI,HART,OVP,Ex ia/Exd

      Overvoltage protection, RFI-filter. Not for TIIS Ex ia, TIIS Ex d. Usage: FMB70, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

  • 40
    • Nr 40 Order code 71002865

      Display module VU340, Cbar/Dbar/Dpilot S

      Digital display, 3 push buttons, snapped bracket. Languages DE/EN/FR/ES/IT/NL, from software version 02.00.zz; Usage: electronics HART. Languages DE/EN/FR/ES/IT/NL/JA/ZH. From software version 02.01.zz; Electronics HART. Languages DE/EN/FR/ES/IT/JA/ZH/RU, from software version 02.11.zz; Electronics HART. From software version 04.00.zz; Electronics PROFIBUS PA. From software version 03.00.zz; Electronics FOUNDATION Fieldbus, FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP72/PMP75. From software version 01.00.zz; Electronics HART, FMD71/FMD72.

  • 55
    • Nr 55 Order code 52020217

      Adapter PMC71 G1/2, d11.4, Da30, 316L

      Process adapter thread external G1/2, internal 11.5mm. Usage: PMC71, interchangeable threaded boss.

    • Nr 55 Order code 52020224

      Adapter PMC71 PF1/2, d3, 316L, 3.1

      Process adapter thread external PF1/2. Material test certificate, wetted parts, Inspection cert. EN10204-3.1 material. Usage: PMC71, interchangeable threaded boss.

    • Nr 55 Order code 52020225

      Adapter PMC71 G1/2, d11.4, 316L, 3.1

      Process adapter thread external G1/2, internal 11.5mm. Material test certificate, wetted parts, Inspection cert. EN10204-3.1 material. Usage: PMC71, interchangeable threaded boss.

    • Nr 55 Order code 52020226

      Adapter PMC71 PT1/2, d11.4, 316L, 3.1

      Process adapter thread external PT1/2, internal 11.5mm. Material test certificate, wetted parts, Inspection cert. EN10204-3.1 material. Usage: PMC71, interchangeable threaded boss.

    • Nr 55 Order code 52020227

      Adapter PMC71 NPT1/2, d11.4, 316L, 3.1

      Process adapter thread external NPT1/2, internal 11.5mm. Material test certificate, wetted parts, Inspection cert. EN10204-3.1 material. Usage: PMC71, interchangeable threaded boss.

    • Nr 55 Order code 52020228

      Adapter PMC71 NPT1/2, NPT1/4, 316L, 3.1

      Process adapter thread external NPT1/2, internal NPT1/4. Material test certificate, wetted parts, Inspection cert. EN10204-3.1 material. Usage: PMC71, interchangeable threaded boss.

    • Nr 55 Order code 52020229

      Adapter PMC71 M20, d3, 316L, 3.1

      Process adapter thread external M20. Material test certificate, wetted parts, Inspection cert. EN10204-3.1 material. Usage: PMC71, interchangeable threaded boss.

    • Nr 55 Order code 52020230

      Adapter PMC71 G1/2, d3, 316L, 3.1

      Process adapter, thread external G1/2. Material test certificate, wetted parts, Inspection cert. EN10204-3.1 material. Usage: PMC71, interchangeable threaded boss.

    • Nr 55 Order code 71007932

      Adapter Cbar S G1-1/2 ISO228,316L,screws

      Process connection, flush mounted. 4x fixing screw M5x16. Usage: PMC71.

  • 58
    • Nr 58 Order code 52020441

      Mounting angle, adapter, screws

      Usage: PMC71, interchangeable threaded boss.

  • 57
    • Nr 57 Order code 52010137

      O-ring 26.7x1.78 FKM 70, O2, 5 pieces

      Oxygen use. Cleaned from oil + grease. Usage: PMC45, PMC71, ceramic cell.

    • Nr 57 Order code 52010155

      O-ring 26.7x1.78 HNBR 75, 3A, FDA, 5 pcs

      Application: hygienic. Usage: FMD71, PMC45, PMC51, PMC71.

    • Nr 57 Order code 52017989

      O-ring 26.7x1.78 EPDM 70, 3A, USP, 5 pcs

      Usage: FMD71, PMC51, PMC71.

    • Nr 57 Order code 52020768

      O-ring 26.7x1.78 FKM70,degreased, 5 pcs.

      Cleaned from oil+grease. Usage: PMC71.

    • Nr 57 Order code 52020769

      O-ring 26.7x1.78 NBR 70, 5 pieces

      Usage: FMD71, PMC51, PMC71.

    • Nr 57 Order code 52020770

      O-ring 26.7x1.78 EPDM 70, 5 pieces

      Usage: FMD71, PMC51, PMC71.

    • Nr 57 Order code 52020771

      O-ring 26.7x1.78 FKM -40oC, 5 pieces

      Usage: FMD71, PMC51, PMC71.

    • Nr 57 Order code 52020772

      O-ring 26.7x1.78 FFKM 70 KALREZ, 1 pc.

      Usage: FMD71, PMC51, PMC71.

    • Nr 57 Order code 52020773

      O-ring 26.7x1.78 FFKM 75 CHEMRAZ, 1 pc.

      Usage: PMC71.

    • Nr 57 Order code 71093308

      O-ring 26.7x1.78 FKM, FDA, 5 pieces

      Usage: FMD71, PMC51, PMC71.

    • Nr 57 Order code 71316464

      O-ring 27.1x1.6 FFKM 75 Perlast, 1pc.

      Usage: FMD71, PMC51, PMC71.

  • 50
    • Order code 71102216

      Mountingset Cerabar,Deltapilot,Levelflex

      Material: 316L. Usage: wall/pipe mounting (2"), FMB50/FMB51/FMB52/FMB53, FMB70, FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/ FMP56/FMP57, PMC51, PMC71, PMP51/PMP55, PMP71/PMP75.

    • Order code 71304770

      Mountingset, housing T14, special

      Material: 316L. Usage: mounting kit to attach the own mounting bracket / weather protection cover, FMB70, PMC71, PMP71/PMP75.

    • Order code 71372498

      Mounting bracket 2 valve,stainless steel

      Mounting set Manifold. Material: 316L. Consists of: 1x Mounting bracket. 1x U-bolts. 2x Washers A 8.4. 2x Hexagon nuts M8. Usage: wall/pipe mounting 2", DA63M, PMC51, PMC71, PMP51, PMP71.

    • Order code 52024469

      Weld-in adapter G1-1/2, 316L

      Mounting process connection G1-1/2. Material: 316L. Correct installation only with dummy. Usage: FMB50/FMB51/FMB52, FMB70, PMC51, PMC71, PMP51/PMP55, PMP71/PMP75.

    • Order code 52024470

      Weld-in adapter G1-1/2, 316L, 3.1

      Mounting process connection G1-1/2. Material: 316L. Inspection cert. EN10204-3.1 material. Usage: FMB50/FMB51/FMB52, FMB70, PMC51, PMC71, PMP51/PMP52, PMP71/PMP75.

    • Order code 52002041

      Weld-in adapter DRD DN50, 316L

      Front-flush mounting of devices with DRD flange. Material: 316L. Seal: PTFE flat. FDA compliant. Usage: FMB50, FMB70, FMD78, FTL50/FTL50H/FTL51/FTL51C/FTL51H, PMC51, PMC71, PMP51/PMP55, PMP75.

    • Order code 52011899

      Weld-in adapter DRD DN50, 316L, 3.1

      Flush mount process connection of devices with DRD flange. Material: 316L. Inspection cert. EN10204-3.1 material. Seal: PTFE flat. FDA compliant. Usage: FMB50, FMB70, FMD78, FTL50/FTL50H/FTL51/FTL51C/FTL51H, PMC51, PMC71, PMP51/PMP55, PMP75.

    • Order code 52024228

      Flat seal 50x65x1 PTFE, FDA, 5 pieces

      Fit to weld-in adapter DRD-DN50. Flush mount FTL50H/FTL51H, PMC51, pressure device.

    • Order code 71067434

      Modification name plate, non Ex

      Blank. To fill in the new order code when a non Ex instrument has been modified. Usage: FMB50/FMB51/FMB52, FMR230/FMR231, FMR240/FMR244/FMR245, FMR250,FMR530/FMR532,FTL50/FTL50H/FTL51/ FTL51C/FTL51H, FTL70/FTL71, FTL80/FTL81/ FTL85, NMR81, PMC51, PMC71, PMP51/PMP55.

    • Order code 71007843

      ToF Adapter FXA291

      Usage: connection Micropilot M, Micropilot S, Levelflex M, Prosonic M, Tank Side Monitor, Deltabar S, Cerabar S, Gammapilot M, Micropilot I, to Commubox FXA291.

    • Order code 71000221

      Adapterk. FMR2xx,FMx4x,PMx7x,FMD7x,FMG60

      Connection service tool RS232(52013675)/ ToF adapter FXA291 (71007843). Usage: FMG60, FMD77/FMD78, FMR230/ FMR231, FMR240/FMR244/FMR245, FMR250, FMU40/FMU41/FMU42/FMU43/FMU44, NRF590, PMC71, PMD75, PMP71/PMP75.

    • Order code XPRFID-

      Spare RFID TAG

      Consists of: RFID TAG, fixing wire, crimp sleeve.

    • Order code 71386153

      Electronics HART Ex, ext. p. b., v2.30

      4-20mA. Software version 02.30.zz, HART 7, DevRev23. Push button on housing. Usage: FMB70, FMD77/FMD78, PMC71, PMD75, PMP71/PMP75. Not for MID parts certificate (PMP71).

  • Forgænger