Prøv at søge efter nøgleord, ordre- eller produktkode eller serienummer, f.eks. “CM442” eller “Teknisk information”
Indtast mindst 2 tegn for at starte søgningen.
Liquiphant FTL51 - Vibronic

Vibronic
Point level detection
Liquiphant FTL51

Point level switch with extension tube for liquids in all industries

FTL51
Please Wait (spinning wheel)
Indlæser pris
Priser er midlertidigt utilgængelige
Price on request
aktiverer pris
pris: information ønskes
from CHF ??.-
Filtrer måle- / anvendelsesopgave
Måle- / Anvendelsesopgave

Konfigurer for at downloade CAD-tegninger af dette produkt

  • Measuring principle

    Vibration Liquids

  • Characteristic / Application

    Modular housing concept
    wide range of process connections
    Analogue and bus interfaces
    Extensive certificate range (e.g. Ex,WHG)
    pipe extension up to 3m (6m option)

  • Specialities

    Foamdetection
    Detect a densitychange
    second line of defense

  • Supply / Communication

    PROFIBUS PA
    19...253V AC
    10...55V DC-PNP
    19...253V AC or 10...55V DC
    8/16mA, 11...36V DC
    NAMUR
    PFM

  • Ambient temperature

    -50 °C...+70 °C
    (-58 °F...+158 °F)

  • Process temperature

    -50 °C...+150 °C
    (-58 °F...+302 °F)

  • Process pressure / max. overpressure limit

    Vacuum...100 bar

  • Min. density of medium

    0.5g/cm³(0.4g/cm³ optional)

  • Main wetted parts

    316L / Alloy

  • Process connection

    Thread:
    G3/4A, G1A, R3/4", R1, NPT3/4, NPT1
    Flange:
    DN25...DN100,
    ASME 1"...4",
    JIS 25A...100A

  • Process connection hygienic

    Tri-Clamp ISO2852

  • Sensor length

    Length 130mm (5.12") (Liquiphant II)
    148mm...6000mm (5.83"...236")

  • Communication

    PROFIBUS PA
    19...253V AC
    10...55V DC-PNP
    19...253V AC bzw 10...55V DC
    8/16mA, 11...36V DC
    NAMUR
    PFM

  • Certificates / Approvals

    ATEX, FM, CSA C/US, IEC Ex, TIIS, INMETRO, NEPSI

  • Safety approvals

    SIL2/ SIL3

  • Design approvals

    EN 10204-3.1
    NACE MR0175, MR0103
    ASME B31.3
    AD2000

  • Marine approval

    GL/ ABS/ DNV

  • Options

    Heavy duty stainless steel housing mainly for the oil and gas industry

  • Components

    FTL325P/FTL375P Interface PFM
    FTL325N/FTL375N Interface NAMUR

  • Successor

    Liquiphant FTL51B

  • Measuring principle

    Vibration Density

  • Characteristic / Application

    Liquiphant M Density
    with Density Computer FML621
    Temperature and pressure measurement
    Modular housing concept
    Wide range of process connections
    Pipe extension up to 3 m (6 m option)

  • Supply / Communication

    Transmitter power supply (MUS)

  • Ambient temperature

    -50...70°C
    -50...60°C for hazardous applications

  • Process temperature

    0...80°C (validity of accuracy data)
    -50...0°C / 80...150 °C (with reduced technical data)

  • Process pressure

    0...25 bar
    >25..100 bar (with reduced technical data)

  • Wetted parts

    316L/C4

  • Sensor length

    115...3000 mm
    >3000...6000 mm (Option)

  • Output

    Pulse

  • Certificates / Approvals

    ATEX, FM, CSA C/US, IEC Ex, TIIS, INMETRO, NEPSI

  • Specialities

    Commissioning with ReadWin2000

  • Components

    Density Computer FML621

  • Other approvals and certificates

    SIL2/ SIL3