Anvendelsesområde
The switching unit FTL325P is used for point level detection in liquid tanks and bulk material silos, also in hazardous explosion areas. Also suitable for liquid detection in pipes for dry running protection for pumps and overfill prevention for tanks with combustible or non-combustible liquids harmful to water. Up to 3 measuring devices for two-point control and point level detection. Functional safety up to SIL3 in accordance to IEC 61508 using Liquiphant with electronic insert FEL57.
Switching unit with intrinsically safe signal circuit for connection to Liquiphant or Soliphant.
Ambient temperature: -20 to +70°C (-4 to +158°F)
International explosion protection certificates, overfill prevention WHG, marine approvals
Fordele
Nivotester FTL325P for connecting one, two or three measuring cells (1-, 2- or 3-channel devices)
Intrinsically safe signal circuits Ex ia for use of measuring sensor in explosion hazardous areas
Functional safety up to SIL2 through line monitoring. Simplified proof testing to WHG/SIL by pressing push-button
DIN Rail housing for simple series installation on standard rails in switch cabinet
Simple wiring using pluggable terminal blocks
Inputs are galvanically isolated from each other, from the mains and from the outputs
Extended
Avancerede produkter
Funktionelle og praktiske
Teknisk ydeevne
Enkelhed
©Endress+Hauser
Enkle produkter
Nemme at vælge, installere og betjene
Teknisk ydeevne
Enkelhed
Standardprodukter
Pålidelige og robuste med lav vedligeholdelse
Teknisk ydeevne
Enkelhed
Avancerede produkter
Funktionelle og praktiske
Teknisk ydeevne
Enkelhed
Specialiserede produkter
Designet til krævende applikationer
Teknisk ydeevne
Enkelhed
FLEX valg
Teknisk ydeevne
Enkelhed
Fundamental
Få dækket dine basale målebehov
Teknisk ydeevne
Enkelhed
Lean
Administrer nemt dine kerneprocesser
Teknisk ydeevne
Enkelhed
Extended
Optimer dine processer med innovative teknologier
Teknisk ydeevne
Enkelhed
Xpert
Til de mest udfordrende applikationer
Teknisk ydeevne
Enkelhed
Loading alternative products
Succeshistorier
Time saved, safety increased
Employees of Returkraft regularly have to fulfill and document all requirements of the SIL measuring points in the plant.
Læs hele historien
Fit for purpose instrumentation for CNG compressors
The Egyptian government is working to replace liquid fuels with natural gas. To achieve this they targeted increasing the number of CNG stations in their country from 306 to 1000 by the end of 2021.
Læs hele historien
Udfordrende niveaumåling i bioteknologisk produktion
Hos virksomheden Glycom Manufacturing A/S i Esbjerg betyder størrelsen og den interne geometri på deres store fermentorer, at de har været tvunget til at kigge efter mere end en traditionel niveaumåling.
Læs hele historien
Characteristic / Application
Switching unit PFM technology for rail mounting Intrinsically safe Highest SIL safety
Specialities
If sensors are redundant, SIL3
Supply / Communication
85...253 V AC, 20...30 V AC/ 20...60 V DC
Ambient temperature
Single installation: -20 °C ... 60 °C (-4 °F ... 140 °F) Rail mounting: -20 °C ... 50 °C (-4 °F ... 122 °F)
Communication
1 Channel: 1 Level SPDT + 1 Alarm SPST 3 Channel: 3 level SPDT + 1 Alarm SPST
Certificates / Approvals
ATEX, FM, CSA, IEC Ex, TIIS, INMETRO, NEPSI, EAC
Safety approvals
Overfill prevention WHG SIL
Characteristic / Application
Switching unit PFM technology for rail mounting Intrinsically safe
Supply / Communication
85...253 V AC, 20...30 V AC / 20...60 V DC
Ambient temperature
Single installation: -20 °C ... 60 °C (-4°F ... 140 °F) Rail mounting: -20 °C ... 50 °C (-4 °F ... 122 °F)
Communication
1 Channel: 1 Level SPDT + 1 Alarm SPST 3 Channel: 3 level SPDT + 1 Alarm SPST
Certificates / Approvals
ATEX, FM, CSA, IEC Ex, TIIS, INMETRO, NEPSI
Safety approvals
Overfill prevention WHG SIL
Mest downloadede
Nivotester FTL325P
Engelsk version - 09/2020
Vibronic
EN
DA
DE ES FR IT JA PL PT RU ZH
29/09/2020
28/06/2019
14/08/2015
01/02/2003
Sprog:
Engelsk
Version:
29/09/2020
Filstørrelse:
579.8 KB
Filnavn:
TI00350FEN_1520.pdf
Nivotester FTL325P, single-channel
Engelsk version - 09/2020
Vibronic
EN
DA
DE ES FR IT JA PT RU ZH
29/09/2020
28/06/2019
Sprog:
Engelsk
Version:
29/09/2020
Filstørrelse:
618.6 KB
Filnavn:
BA01971FEN_0220.pdf
56 dokumenter
EN
DA
Tysk Spansk French Italiensk Japansk Polsk Portugisisk Russisk Kinesisk
29/09/2020
28/06/2019
14/08/2015
01/02/2003
Sprog:
Engelsk
Version:
29/09/2020
Filstørrelse:
579.8 KB
Filnavn:
TI00350FEN_1520.pdf
Nivotester FTL325P, 3-channel
Vibronic
EN
DA
Tysk Spansk French Italiensk Japansk Portugisisk Russisk Kinesisk
21/06/2021
29/09/2020
28/06/2019
Sprog:
Engelsk
Version:
21/06/2021
Filstørrelse:
1.2 MB
Filnavn:
BA01970FEN_0321.pdf
Nivotester FTL325P, single-channel
Vibronic
EN
DA
Tysk Spansk French Italiensk Japansk Portugisisk Russisk Kinesisk
29/09/2020
28/06/2019
Sprog:
Engelsk
Version:
29/09/2020
Filstørrelse:
618.6 KB
Filnavn:
BA01971FEN_0220.pdf
Nivotester FTL325P, tre kanaler
Vibronisk
EN
DA
Bulgarsk Tjekkisk Tysk Græsk Spansk Estisk Finsk French Kroatisk Ungarsk Indonesisk Italiensk Japansk Koreansk Lithuanian Latvian Hollandsk Norsk Polsk Portugisisk Rumænsk Russisk Slovakisk Slovensk Svensk Thai Tyrkisk Kinesisk
21/06/2021
29/09/2020
28/06/2019
Sprog:
Dansk
Version:
21/06/2021
Filstørrelse:
880.8 KB
Filnavn:
KA01432FDA_0321.pdf
Nivotester FTL325P med én kanal
Vibronisk
EN
DA
Bulgarsk Tjekkisk Tysk Græsk Spansk Estisk Finsk French Kroatisk Ungarsk Indonesisk Italiensk Japansk Koreansk Lithuanian Latvian Hollandsk Norsk Polsk Portugisisk Rumænsk Russisk Slovakisk Slovensk Svensk Thai Tyrkisk Kinesisk
29/09/2020
28/06/2019
Sprog:
Dansk
Version:
29/09/2020
Filstørrelse:
544.9 KB
Filnavn:
KA01431FDA_0220.pdf
Bedienungsanleitung/ Operating Instuctions Liquiphant M/S + FEL57
Selbsttest Self test
EN
DA
Tysk Spansk French Italiensk Hollandsk Russisk Kinesisk
27/02/2017
01/03/2002
Sprog:
Engelsk
Version:
27/02/2017
Filstørrelse:
227.1 KB
Filnavn:
KA00147FA6_1316.pdf
Nivotester FTL 325 P-# 1# 1Bedienungsanleitung
Füllstandgrenzschalter mit PFM- Eingang.
EN
DA
Tjekkisk Tysk Spansk French Italiensk Japansk Hollandsk Portugisisk Russisk
24/07/2015
01/04/2001
Sprog:
Engelsk
Version:
24/07/2015
Filstørrelse:
440.9 KB
Filnavn:
KA00167FA6_1315.pdf
Nivotester FTL325
Betriebsanleitung
Mit eigensicherem Signalstromkreis zum Anschluss an Messaufnehmer Liquiphant und Soliphant
EN
DA
Tysk Spansk French Italiensk Japansk Hollandsk Russisk
24/07/2015
16/02/2004
01/04/2001
Sprog:
Engelsk
Version:
24/07/2015
Filstørrelse:
605.2 KB
Filnavn:
KA00168FA6_1315.pdf
[Ex ia Ga] IIC [Ex ia Da] IIIC
EN
DA
Kinesisk
27/05/2022
23/03/2020
21/08/2017
20/11/2012
01/12/2006
Sprog:
Engelsk
Version:
27/05/2022
Filstørrelse:
758.1 KB
Filnavn:
XA00396FEN_1622-00.pdf
[Ex ia Ga] IIC [Ex ia Da] IIIC
Sprog:
Engelsk
Version:
07/02/2022
Filstørrelse:
415.7 KB
Filnavn:
XA02819FEN_0122-00.pdf
EN
DA
Portugisisk
20/06/2022
23/03/2020
13/01/2015
Sprog:
Engelsk
Version:
20/06/2022
Filstørrelse:
428.9 KB
Filnavn:
XA01340FEN_0322-00.pdf
Control Drawing AIS Cl. I, Div. 1, Group A, B / C, D; [AEx ia Ga] IIC / IIB AIS Cl. II, III, Div. 1, Groups E-G; [AEx ia Da] IIIC
EN
DA
08/02/2023
06/10/2022
28/01/2017
Sprog:
Engelsk
Version:
08/02/2023
Filstørrelse:
418.2 KB
Filnavn:
XA01433FEN_0223-00.pdf
II (1) G [Ex iaGa] IIC II (1) D [Ex ia Da] IIIC
Sprog:
Engelsk
Version:
01/03/2022
Filstørrelse:
418 KB
Filnavn:
XA02826FEN_0122-00.pdf
II 3 (1) G Ex ec nC [ia Ga] IIC Gc
Sprog:
Engelsk
Version:
01/03/2022
Filstørrelse:
411.2 KB
Filnavn:
XA02827FEN_0122-00.pdf
ATEX: II (1) G[Ex ia Ga] IIC II (1) D [Ex ia Da] IIIC IECEx: [Ex ia Ga] IIC [Ex ia Da] IIIC
EN
DA
Bulgarsk Tjekkisk Tysk Græsk Spansk Estisk Finsk French Kroatisk Ungarsk Italiensk Lithuanian Latvian Hollandsk Polsk Portugisisk Rumænsk Slovakisk Slovensk Svensk
22/11/2021
23/03/2020
15/04/2016
05/10/2015
23/02/2011
Sprog:
Dansk
Version:
22/11/2021
Filstørrelse:
420.2 KB
Filnavn:
XA00133FDA_1721-00.pdf
2Ex ec nC [ia Ga] IIC T4 Gc X
Sprog:
Engelsk
Version:
15/08/2022
Filstørrelse:
414.5 KB
Filnavn:
XA02906FEN_0122-00.pdf
ATEX: II 3 (1)G Ex ec nC [ia Ga] IIC T4 Gc IECEx: Ex ec nC [ia Ga] IIC T4 Gc
EN
DA
Bulgarsk Tjekkisk Tysk Græsk Spansk Estisk Finsk French Kroatisk Ungarsk Italiensk Lithuanian Latvian Hollandsk Polsk Portugisisk Rumænsk Slovakisk Slovensk Svensk
22/11/2021
23/03/2020
12/09/2017
23/02/2011
Sprog:
Dansk
Version:
22/11/2021
Filstørrelse:
417.9 KB
Filnavn:
XA00526FDA_1621-00.pdf
Safety Instructions
Nivotester FTL325P
ATEX: II (1) G [Ex ia Ga] IIC, II (1) D [Ex ia Da] IIIC IECEx: [Ex ia Ga] IIC, [Ex ia Da] IIIC DMT 01 ATEX E 052; IECEx BVS 15.0085
EN
DA
Tysk French Ungarsk
08/06/2016
01/07/2009
01/08/2005
Sprog:
Engelsk
Version:
08/06/2016
Filstørrelse:
1 MB
Filnavn:
XA00347FA3_1316.pdf
[Ex ia Ga] IIC X [Ex ia Da] IIIC X
EN
DA
Russisk
15/08/2022
23/03/2020
23/02/2018
30/01/2018
30/09/2017
Sprog:
Engelsk
Version:
15/08/2022
Filstørrelse:
421 KB
Filnavn:
XA01677FEN_0522-00.pdf
Safety Instructions
Nivotester FTL325P
Class I, II, III Division 1 or 2 Groups A, B, C, D, E, F, G Class I, Zone 0, Ex ia IIC
Sprog:
Engelsk
Version:
28/01/2017
Filstørrelse:
441.5 KB
Filnavn:
XA01434FEN_0116.pdf
Vi værner om dine personlige oplysninger
Vi anvender cookies for at forbedre din browseroplevelse, indsamle statistiske oplysninger med henblik på optimering af webstedets funktionalitet og levere skræddersyede annoncer eller indholdselementer.
Hvis du vælger "Accepter alle", giver du dit samtykke til vores brug af cookies.
Yderligere oplysninger fremgår af vores Cookiepolitik .
Tilpas
Accepter kun essentielle
Accepter alle