Oversigt over specifikationer
-
Process temperature
0 to 140 °C (32 to 284 °F)
-
Process pressure
0 to max. 4 bar (0 to max. 58 psi) overpressure for manual actuation
0 to 10 bar (0 to 145 psi) overpressure for pneumatic actuation
Anvendelsesområde
The Cleanfit CPA472D assembly is designed for harsh process conditions. It offers a great variety of rugged materials to operate your sensors safely even under high pressure, high temperature or in aggressive media. The assembly allows you to replace sensors without interrupting the process or to clean and calibrate them automatically via the optional control system. Benefit from easy, time-saving sensor handling and an extended operating life of the sensors.
The Cleanfit CPA472D is intended for installation in tanks or pipes in:
Chemical industry
Power plants
Biodiesel plants
It is suitable for use with pressures of up to 10 bar.
Fordele
Extremely robust: Suitable for use with pressures of up to 10 bar and temperatures of up to 140° C even as PEEK, PVDF, conductive PVDF versions
Maximum chemical resistance ensures long operating times
No process interruption for electrode cleaning and calibration – saves maintenance time and costs
Flexible adaptation to all applications by great variety of materials and process connections
-
Standardprodukter
- Pålidelige og robuste med lav vedligeholdelse
Teknisk ydeevne
Enkelhed
-
Specialiserede produkter
- Designet til krævende applikationer
Teknisk ydeevne
Enkelhed
Variabel
| FLEX valg | Teknisk ydeevne | Enkelhed |
|---|---|---|
Fundamental Få dækket dine basale målebehov |
Teknisk ydeevne
|
Enkelhed
|
Lean Administrer nemt dine kerneprocesser |
Teknisk ydeevne
|
Enkelhed
|
Extended Optimer dine processer med innovative teknologier |
Teknisk ydeevne
|
Enkelhed
|
Xpert Til de mest udfordrende applikationer |
Teknisk ydeevne
|
Enkelhed
Variabel |
-
Measuring principle
Potentiometric
-
Application
Chemical industry, biodiesel plants, power plants, plant design, tanks, process vats or pipes
-
Installation
Retractable holder
-
Characteristic
For tanks and process vats and pipelines or pipes (min. DN80)
The robust retractable assembly permits replacement of the electrode while the tank is full or under process conditions with pressures of up to 6 bar -
Design
Manual or pneumatical
-
Material
Electrode holder, rinse chamber and raised face:
PEEK, PVDF, conductive PVDF, Alloy C22, stainless steel 1.4571
Seals: EPDM, FPM (Viton) or FFKM (Kalrez®) -
Dimension
Immersion depth: 146 or 280 mm (5.75 or 7.87 inch)
-
Process temperature
0 to 140 °C (32 to 284 °F)
-
Process pressure
0 to max. 4 bar (0 to max. 58 psi) overpressure for manual actuation
0 to 10 bar (0 to 145 psi) overpressure for pneumatic actuation -
Connection
Process connections: Flange DN 50, DN 80, ANSI 2", JIS IS10K50A, internal thread G1¼
-
Measuring principle
Sensor ORP / Redox
-
Application
Chemical industry, biodiesel plants, power plants, plant design, tanks, process vats or pipes
-
Installation
Retractable holder
-
Characteristic
For tanks and process vats and pipelines or pipes (min. DN80)
The robust retractable assembly permits replacement of the electrode while the tank is full or under process conditions with pressures of up to 6 bar -
Design
Manual or pneumatical
-
Material
Electrode holder, rinse chamber and raised face:
PEEK, PVDF, conductive PVDF, Alloy C22, stainless steel 1.4571
Seals: EPDM, FPM (Viton) or FFKM (Kalrez®) -
Dimension
Immersion depth: 146 or 280 mm (5.75 or 7.87 inch)
-
Process temperature
0 to 140 °C (32 to 284 °F)
-
Process pressure
0 to max. 4 bar (0 to max. 58 psi) overpressure for manual actuation
0 to 10 bar (0 to 145 psi) overpressure for pneumatic actuation -
Connection
Process connections: Flange DN 50, DN 80, ANSI 2", JIS IS10K50A, internal thread G1¼
-
-
Tekniske oplysninger (TI)
Technical Information Topcal S CPC310
-
Tekniske oplysninger (TI)
Engelsk version - 07/2015New version available in EnglishFully automatic measuring, cleaning and calibration system in hazardous
and non-hazardous areasEN DA 22/07/201501/07/2006Sprog:
Engelsk
Version:
22/07/2015
Filstørrelse:
2 MB
Filnavn:
TI00404CEN_1315.pdf
-
-
-
Tekniske oplysninger (TI)
Technical Information Cleanfit P CPA472D
-
Tekniske oplysninger (TI)
Engelsk version - 10/2013New version available in EnglishRetractable process assembly for pH, ORP and other industry electrodes
Heavy duty versionEN DA 08/10/201301/06/201001/05/2006Sprog:
Engelsk
Version:
08/10/2013
Filstørrelse:
940.5 KB
Filnavn:
TI00403CEN_1313.pdf
-
-
-
Betjeningsvejledning (BA)
Operating Instructions Cleanfit CPA472D
-
Betjeningsvejledning (BA)
Engelsk version - 10/2013New version available in EnglishRetractable Process Assembly
EN DA 08/10/201301/09/201001/05/2006Sprog:
Engelsk
Version:
08/10/2013
Filstørrelse:
1.3 MB
Filnavn:
BA00403CEN_1313.pdf
-
-
-
Installationsanvisninger (EA)
EA for Cleanfit CPA472D
-
Installationsanvisninger (EA)
Engelsk version - 02/2025New version available in EnglishService Manual for Retractable Process Assembly Cleanfit CPA472D
EN DA 20/02/2025Sprog:
Engelsk
Version:
20/02/2025
Filstørrelse:
3.1 MB
Filnavn:
71217188_Service_CPA472D.pdf
-
-
-
Installationsanvisninger (EA)
EA retrofit for Cleanfit CPA472D
-
Installationsanvisninger (EA)
Engelsk version - 02/2025New version available in EnglishRetrofit manual of retractable process assembly Cleanfit CPA472D
EN DA 20/02/2025Sprog:
Engelsk
Version:
20/02/2025
Filstørrelse:
3.8 MB
Filnavn:
71297785_Umbau_CPA472D.pdf
-
-
-
Installationsanvisninger (EA)
EA Kits/Kit for CPA47x
-
Installationsanvisninger (EA)
Engelsk version - 09/2025New version available in EnglishSpare parts kits for CPA47x limit switches
EN DA 09/09/2025Sprog:
Engelsk
Version:
09/09/2025
Filstørrelse:
962.5 KB
Filnavn:
71201542_cpa47x_endlagenschalter.pdf
-
-
-
Installationsanvisninger (EA)
EA Spare parts kits for Cleanfit CPA472D, CPA473 and CPA474 process retractable assemblies
-
Installationsanvisninger (EA)
Engelsk version - 02/2025New version available in EnglishSeals, not in contact with medium
EN DA 19/02/2025Sprog:
Engelsk
Version:
19/02/2025
Filstørrelse:
934.3 KB
Filnavn:
EA01523CEN_0125-00.pdf
-
-
-
Kompetencebrochure (CP)
pH measurement in industrial processes
-
Kompetencebrochure (CP)
Engelsk version - 12/2021New version available in EnglishSelection and engineering guide for different industries and
applicationsSprog:
Engelsk
Version:
02/12/2021
Filstørrelse:
3.2 MB
Filnavn:
CP00010CEN_1621_pH selection guide_2021.pdf
-
-
-
Kompetencebrochure (CP)
産業プロセスにおけるpH測定
-
Kompetencebrochure (CP)
Japansk version - 02/2024New version available in Englishさまざまな産業およびアプリケーション向けのpH測定セレクションガイド
Sprog:
Japansk
Version:
08/02/2024
Filstørrelse:
2.6 MB
Filnavn:
CP00010CJA_1315_1024_pH_selection_guide.pdf
-
-
-
Kompetencebrochure (CP)
pH-Messung in Industrieprozessen
-
Kompetencebrochure (CP)
Tysk version - 12/2021New version available in EnglishAuswahl- und Engineering-Hilfe für verschiedene Industriebranchen und
ApplikationenSprog:
Tysk
Version:
01/12/2021
Filstørrelse:
3.3 MB
Filnavn:
CP00010CDE_1621_pH Auswahlhilfe_2021.pdf
-
Vælg blandt de foreslåede muligheder
-
-- selected coding-- selected label99.999,00<%label%>
-
Leder du efter flere indstillinger? Anvend den individuelle konfigurator for at fortsætte.
-
-- selected coding-- selected label99.999,00<%feature%>
-
<%label%>99.999,00
-
Leder du efter flere indstillinger? Anvend den individuelle konfigurator for at fortsætte.
-
Process Connection
-
<%label%>99.999,00
-
<%label%>99.999,00
-
-
<%feature%><%coding%><%label%>
- CAD-tegninger CAD-tegninger
- CAD-tegninger
-
Pris pr. enhed
-
<%range%><%price%>
-
- Valgfrie tilføjelser
Individuel konfiguration
Ofte købt sammen
Tilbehør
Relaterede produkter