Dette produkt er ikke længere tilgængeligt.
Se den nye generation i afsnittet med forgængere/efterfølgere, eller kontakt den lokale Endress+Hauser-afdeling.
-
Afløser
-
Standardprodukter
- Pålidelige og robuste med lav vedligeholdelse
Teknisk ydeevne
Enkelhed
-
Specialiserede produkter
- Designet til krævende applikationer
Teknisk ydeevne
Enkelhed
Variabel
FLEX valg Teknisk ydeevne Enkelhed - F
- L
- E
- X
Fundamental
Få dækket dine basale målebehov
Teknisk ydeevne Enkelhed - F
- L
- E
- X
Lean
Administrer nemt dine kerneprocesser
Teknisk ydeevne Enkelhed - F
- L
- E
- X
Extended
Optimer dine processer med innovative teknologier
Teknisk ydeevne Enkelhed - F
- L
- E
- X
Xpert
Til de mest udfordrende applikationer
Teknisk ydeevne Enkelhed Variabel
-
-
Measuring principle
Coriolis
-
Product headline
The easy‐to‐clean flowmeter with self‐drainable single‐tube system and a compact or remote transmitter. Dedicated for applications requiring optimal cleanability under hygienic conditions.
-
Sensor features
Reduced installation costs – fully self‐drainable tube design enables compact horizontal mounting. Fewer process measuring points – multivariable measurement (flow, density, temperature). Spacesaving installation – no in/outlet run needs. Large range of hygienic process connections. 3-A conform.
-
Transmitter features
Cost‐effective – dedicated design for standard applications. Safe operation – display provides easy readable process information. Fully industry compliant – IEC/EN/NAMUR. 2‐line backlit display with push buttons. Device in compact or remote version.
-
Nominal diameter range
DN 8 to 50 (⅜ to 2")
-
Wetted materials
Measuring tube: 1.4539 (904L)
Connection: 1.4435 (316L); 1.4404 (316/316L) -
Measured variables
Mass flow, density, temperature, volume flow, corrected volume flow, reference density
-
Max. measurement error
Mass flow (liquid): ±0.15 %
Volume flow (liquid): ±0.15 %
Mass flow (gas): ±0.5 %
Density (liquid): ±0.0005 g/cm³ -
Measuring range
0 to 70 000 kg/h (0 to 2570 lb/min)
-
Max. process pressure
PN 63, Class 300, 40K
-
Medium temperature range
–50 to +150 °C (–58 to +302 °F)
-
Ambient temperature range
Standard: –20 to +60 °C (–4 to +140 °F)
Option: –40 to +60 °C (–40 to +140 °F) -
Sensor housing material
1.4301 (304), corrosion resistant
-
Transmitter housing material
Powder‐coated die‐cast aluminium
1.4301 (304), sheet
CF3M (316L), cast -
Degree of protection
IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure
-
Display/Operation
2‐line backlit display with push buttons
Configuration via local display and operating tools possible -
Outputs
3 outputs:
0‐20 mA (active)/4‐20 mA (active/passive)
Pulse/frequency/switch output (passive) -
Inputs
Status input
-
Digital communication
HART
PROFIBUS PA -
Power supply
DC 16 to 62 V
AC 85 to 260 V (45 to 65 Hz)
AC 20 to 55 V (45 to 65 Hz) -
Hazardous area approvals
ATEX, IECEx, FM, CSA, NEPSI
-
Other approvals and certificates
3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR, SIL
PED, CRN
3-A, FDA -
Product safety
CE, C-tick, EAC marking
-
Functional safety
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
-
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
-
Pressure approvals and certificates
PED, CRN
-
Material certificates
3.1 material
-
Hygienic approvals and certificates
3-A, FDA
-
Measuring principle
Coriolis
-
Product headline
The easy‐to‐clean flowmeter with self‐drainable single‐tube system and a compact or remote transmitter. Dedicated for applications requiring optimal cleanability under hygienic conditions.
-
Sensor features
Reduced installation costs – fully self‐drainable tube design enables compact horizontal mounting. Fewer process measuring points – multivariable measurement (flow, density, temperature). Spacesaving installation – no in/outlet run needs. Large range of hygienic process connections. 3-A conform.
-
Transmitter features
Cost‐effective – dedicated design for standard applications. Safe operation – display provides easy readable process information. Fully industry compliant – IEC/EN/NAMUR. 2‐line backlit display with push buttons. Device in compact or remote version.
-
Nominal diameter range
DN 8 to 50 (⅜ to 2")
-
Wetted materials
Measuring tube: 1.4539 (904L)
Connection: 1.4435 (316L); 1.4404 (316/316L) -
Measured variables
Mass flow, density, temperature, volume flow, corrected volume flow, reference density
-
Max. measurement error
Mass flow (liquid): ±0.15 %
Volume flow (liquid): ±0.15 %
Mass flow (gas): ±0.5 %
Density (liquid): ±0.0005 g/cm³ -
Measuring range
0 to 70 000 kg/h (0 to 2570 lb/min)
-
Max. process pressure
PN 63, Class 300, 40K
-
Medium temperature range
–50 to +150 °C (–58 to +302 °F)
-
Ambient temperature range
Standard: –20 to +60 °C (–4 to +140 °F)
Option: –40 to +60 °C (–40 to +140 °F) -
Sensor housing material
1.4301 (304), corrosion resistant
-
Transmitter housing material
Powder‐coated die‐cast aluminium
1.4301 (304), sheet
CF3M (316L), cast -
Degree of protection
IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure
-
Display/Operation
2‐line backlit display with push buttons
Configuration via local display and operating tools possible -
Outputs
3 outputs:
0‐20 mA (active)/4‐20 mA (active/passive)
Pulse/frequency/switch output (passive) -
Inputs
Status input
-
Digital communication
HART
PROFIBUS PA -
Power supply
DC 16 to 62 V
AC 85 to 260 V (45 to 65 Hz)
AC 20 to 55 V (45 to 65 Hz) -
Hazardous area approvals
ATEX, IECEx, FM, CSA, NEPSI
-
Other approvals and certificates
3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR, SIL
PED, CRN
3-A, FDA -
Product safety
CE, C-tick, EAC marking
-
Functional safety
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
-
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
-
Pressure approvals and certificates
PED, CRN
-
Material certificates
3.1 material
-
Hygienic approvals and certificates
3-A, FDA
-
Measuring principle
Coriolis
-
Characteristic / Application
Coriolis mass and density flowmeter for the food and beverage industry.
-
Ambient temperature
-20...+65°C
(-4...140°F) -
Process temperature
-50...+150°C
(-58...+302°F) -
Process pressure
PN 16...40
Cl 150...300
JIS 20...40K -
Wetted parts
904L/1.4539
-
Output
4...20mA
Pulse/Frequency
Status -
Certificates / Approvals
ATEX
FM
CSA IECEx TIIS NEPSI
-
Measuring principle
Coriolis
-
Product headline
The easy‐to‐clean flowmeter with self‐drainable single‐tube system and a compact or remote transmitter. Dedicated for applications requiring optimal cleanability under hygienic conditions.
-
Sensor features
Reduced installation costs – fully self‐drainable tube design enables compact horizontal mounting. Fewer process measuring points – multivariable measurement (flow, density, temperature). Spacesaving installation – no in/outlet run needs. Large range of hygienic process connections. 3-A conform.
-
Transmitter features
Cost‐effective – dedicated design for standard applications. Safe operation – display provides easy readable process information. Fully industry compliant – IEC/EN/NAMUR. 2‐line backlit display with push buttons. Device in compact or remote version.
-
Nominal diameter range
DN 8 to 50 (⅜ to 2")
-
Wetted materials
Measuring tube: 1.4539 (904L)
Connection: 1.4435 (316L); 1.4404 (316/316L) -
Measured variables
Mass flow, density, temperature, volume flow, corrected volume flow, reference density
-
Max. measurement error
Mass flow (liquid): ±0.15 %
Volume flow (liquid): ±0.15 %
Mass flow (gas): ±0.5 %
Density (liquid): ±0.0005 g/cm³ -
Measuring range
0 to 70 000 kg/h (0 to 2570 lb/min)
-
Max. process pressure
PN 63, Class 300, 40K
-
Medium temperature range
–50 to +150 °C (–58 to +302 °F)
-
Ambient temperature range
Standard: –20 to +60 °C (–4 to +140 °F)
Option: –40 to +60 °C (–40 to +140 °F) -
Sensor housing material
1.4301 (304), corrosion resistant
-
Transmitter housing material
Powder‐coated die‐cast aluminium
1.4301 (304), sheet
CF3M (316L), cast -
Degree of protection
IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure
-
Display/Operation
2‐line backlit display with push buttons
Configuration via local display and operating tools possible -
Outputs
3 outputs:
0‐20 mA (active)/4‐20 mA (active/passive)
Pulse/frequency/switch output (passive) -
Inputs
Status input
-
Digital communication
HART
PROFIBUS PA -
Power supply
DC 16 to 62 V
AC 85 to 260 V (45 to 65 Hz)
AC 20 to 55 V (45 to 65 Hz) -
Hazardous area approvals
ATEX, IECEx, FM, CSA, NEPSI
-
Product safety
CE, C-tick, EAC marking
-
Functional safety
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
-
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
-
Pressure approvals and certificates
PED, CRN
-
Material certificates
3.1 material
-
Hygienic approvals and certificates
3-A, FDA
-
-
Tekniske oplysninger (TI)
Proline Promass 80S, 83S Technical Information (SI units)
-
Tekniske oplysninger (TI)
Engelsk version - 01/2010New version available in EnglishCoriolis Mass Flow Measuring System
"The single-tube system with a ""fit-and-forget"" design: "
easy to clean – hygienic – drainable –does not harm the material
being measured – chemical-resistant materialEN DA 25/01/201001/07/200801/03/200801/12/2006Sprog:
Engelsk
Version:
25/01/2010
Filstørrelse:
1.9 MB
Filnavn:
TI076DEN_1009.pdf
-
-
-
Betjeningsvejledning (BA)
Proline Promass 80 PROFIBUS PA Operating Instructions
-
Betjeningsvejledning (BA)
Engelsk version - 10/2012New version available in EnglishCoriolis Mass Flow Measuring System (withPROFIBUS PA interface) for
measuring the mass flow rate, density and temperature of fluids and
gases.The description of the device functions are in a separate
documentation.EN DA 15/10/201208/06/201001/11/200801/12/200701/12/2006Sprog:
Engelsk
Version:
15/10/2012
Filstørrelse:
2.1 MB
Filnavn:
BA00072DEN_1312.pdf
-
-
-
Betjeningsvejledning (BA)
Proline Promass 80 PROFIBUS PA Description of Device Functions
-
Betjeningsvejledning (BA)
Engelsk version - 06/2010New version available in EnglishDescription of the device functions (0ptions and inputs). Additional
documentation for Operating Instructions PROline Promass 80 PROFIBUS PA.EN DA 08/06/201001/11/200801/12/200701/12/200501/06/2001Sprog:
Engelsk
Version:
08/06/2010
Filstørrelse:
743 KB
Filnavn:
BA073DEN_0610.pdf
-
-
-
Betjeningsvejledning (BA)
Proline Promass 80 HART Operating Instructions
-
Betjeningsvejledning (BA)
Engelsk version - 10/2012New version available in EnglishCoriolis Mass Flow Measuring System for measuring the mass flow rate,
density and temperature of fluids and gases. The descriptionof the
device functions are in a separate documentation.EN DA 15/10/201201/03/201001/09/200801/12/200601/12/2005Sprog:
Engelsk
Version:
15/10/2012
Filstørrelse:
1.8 MB
Filnavn:
BA00057DEN_1312.pdf
-
-
-
Betjeningsvejledning (BA)
Proline Promass 80
-
Betjeningsvejledning (BA)
Engelsk version - 09/2008New version available in EnglishDescription of the device functions (0ptions and inputs). Additional
documentation for Operating Instructions PROline Promass 80.EN DA 01/09/200801/12/200501/11/2004Sprog:
Engelsk
Version:
01/09/2008
Filstørrelse:
1.2 MB
Filnavn:
BA058DEN_0908.pdf
-
-
-
Kort anvisning (KA)
Proline Promass 80 Brief Operating Instructions
-
Kort anvisning (KA)
Engelsk version - 08/2015New version available in EnglishCoriolis Mass Flow Measuring System
EN DA 06/08/201515/10/201201/07/2007Sprog:
Engelsk
Version:
06/08/2015
Filstørrelse:
1.3 MB
Filnavn:
KA00023DEN_1415.pdf
-
-
-
Installationsanvisninger (EA)
EA Replacing cover and O-ring
-
Installationsanvisninger (EA)
Engelsk version - 10/2024New version available in EnglishProline 10, 23, 50, 51, 53, 55, 400, 800, 40, 80, 83, 84, 8ME, 8FF, 8FE
,8CM, 90, 91, 92, 93, 65, 72, 73EN DA 15/10/202401/10/201828/06/2012Sprog:
Engelsk
Version:
15/10/2024
Filstørrelse:
797.3 KB
Filnavn:
EA00098DA2_1624-00.pdf
-
-
-
Installationsanvisninger (EA)
Replacing power supply and display Promag 50, 51, 53, 55, Promass 40, 80, 83, 84, 8ME, Cubemass DCI 8CN, CNGmass DCI 8DF, Prosonic Flow 90, 93, t-mass 65
-
Installationsanvisninger (EA)
Engelsk version - 11/2011New version available in EnglishInstallation Instructions
EN DA 18/11/2011Sprog:
Engelsk
Version:
18/11/2011
Filstørrelse:
1.3 MB
Filnavn:
EA00063DA2_14.11.pdf
-
-
-
Installationsanvisninger (EA)
Replacing interface parts Installation Instructions
-
Installationsanvisninger (EA)
Engelsk version - 04/2019New version available in EnglishPromass 40, 80, 83, 84, Cubemass 8CN, CNGmass 8DF
EN DA 01/04/201917/11/2011Sprog:
Engelsk
Version:
01/04/2019
Filstørrelse:
787.5 KB
Filnavn:
EA00036DA2_1519.pdf
-
-
-
Installationsanvisninger (EA)
Replacement Connecting cable Promass 60, 63, 64, 80, 83, 84
-
Installationsanvisninger (EA)
Engelsk version - 12/2009New version available in EnglishInstallation Instructions
EN DA 01/12/2009Sprog:
Engelsk
Version:
01/12/2009
Filstørrelse:
554 KB
Filnavn: