Dette produkt er ikke længere tilgængeligt.
Se den nye generation i afsnittet med forgængere/efterfølgere, eller kontakt den lokale Endress+Hauser-afdeling.
-
Afløser
-
Standardprodukter
- Pålidelige og robuste med lav vedligeholdelse
Teknisk ydeevne
Enkelhed
-
Specialiserede produkter
- Designet til krævende applikationer
Teknisk ydeevne
Enkelhed
Variabel
FLEX valg Teknisk ydeevne Enkelhed - F
- L
- E
- X
Fundamental
Få dækket dine basale målebehov
Teknisk ydeevne Enkelhed - F
- L
- E
- X
Lean
Administrer nemt dine kerneprocesser
Teknisk ydeevne Enkelhed - F
- L
- E
- X
Extended
Optimer dine processer med innovative teknologier
Teknisk ydeevne Enkelhed - F
- L
- E
- X
Xpert
Til de mest udfordrende applikationer
Teknisk ydeevne Enkelhed Variabel
-
-
Measuring principle
Coriolis
-
Product headline
The chemically resistant single‐tube flowmeter with extended transmitter functionality. Highly accurate measurement of liquids and gases in applications requiring highest corrosion resistance.
-
Sensor features
Maximum safety for chemically aggressive fluids – corrosionresistant wetted parts. Fewer process measuring points –multivariable measurement (flow, density, temperature). Spacesaving installation – no in/outlet run needs. Measuring tube made of Tantalum, Zirconium. Nominal diameter: DN 8 to 50 (³⁄₈ to 2").
-
Transmitter features
Quality – software for filling & dosing, density & concentration, advanced diagnostics. Flexible data transfer options – numerous communication types. Automatic recovery of data for servicing. 4‐ line backlit display with touch control. Device in compact or remote version.
-
Nominal diameter range
DN 8 to 50 (³⁄₈ to 2")
-
Wetted materials
Measuring tube: Tantalum 2.5W; 702 (UNS R60702)
Connection: Tantalum; 702 (UNS R60702) -
Measured variables
Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration
-
Max. measurement error
Mass flow (liquid): ±0.1 %
Volume flow (liquid): ±0.1 %
Mass flow (gas, Tantalum only): ±0.5 %
Density (liquid): ±0.0005 g/cm³ -
Measuring range
0 to 70 000 kg/h (0 to 2570 lb/min)
-
Max. process pressure
PN 40, Class 300, 20K
-
Medium temperature range
Tantalum: –50 to +150 °C (–58 to +302 °F)
Ziconium: –50 to +200 °C (–58 to +392 °F) -
Ambient temperature range
Standard: –20 to +60 °C (–4 to +140 °F)
Option: –40 to +60 °C (–40 to +140 °F) -
Sensor housing material
1.4301 (304), corrosion resistant
-
Transmitter housing material
Powder‐coated die‐cast aluminium
1.4301 (304), sheet
CF3M (316L), cast -
Degree of protection
IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure
-
Display/Operation
4‐line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible -
Outputs
4 modular outputs:
0‐20 mA (active)/4‐20 mA (active/passive)
Pulse/frequency/switch output (passive)
Relay -
Inputs
2 modular inputs:
Status
0‐20 mA (active)/4‐20 mA (active/passive) -
Digital communication
HART, PROFIBUS PA/DP, FOUNDATION Fieldbus, Modbus RS485, EtherNet/IP
-
Power supply
DC 16 to 62 V
AC 85 to 260 V (45 to 65 Hz)
AC 20 to 55 V (45 to 65 Hz) -
Hazardous area approvals
ATEX, IECEx, FM, CSA, NEPSI
-
Other approvals and certificates
3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR, SIL
PED, CRN -
Product safety
CE, C-tick, EAC marking
-
Functional safety
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
-
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
-
Pressure approvals and certificates
PED, CRN
-
Material certificates
3.1 material
-
Measuring principle
Coriolis
-
Product headline
The chemically resistant single‐tube flowmeter with extended transmitter functionality. Highly accurate measurement of liquids and gases in applications requiring highest corrosion resistance.
-
Sensor features
Maximum safety for chemically aggressive fluids – corrosionresistant wetted parts. Fewer process measuring points –multivariable measurement (flow, density, temperature). Spacesaving installation – no in/outlet run needs. Measuring tube made of Tantalum, Zirconium. Nominal diameter: DN 8 to 50 (³⁄₈ to 2").
-
Transmitter features
Quality – software for filling & dosing, density & concentration, advanced diagnostics. Flexible data transfer options – numerous communication types. Automatic recovery of data for servicing. 4‐ line backlit display with touch control. Device in compact or remote version.
-
Nominal diameter range
DN 8 to 50 (³⁄₈ to 2")
-
Wetted materials
Measuring tube: Tantalum 2.5W; 702 (UNS R60702)
Connection: Tantalum; 702 (UNS R60702) -
Measured variables
Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration
-
Max. measurement error
Mass flow (liquid): ±0.1 %
Volume flow (liquid): ±0.1 %
Mass flow (gas, Tantalum only): ±0.5 %
Density (liquid): ±0.0005 g/cm³ -
Measuring range
0 to 70 000 kg/h (0 to 2570 lb/min)
-
Max. process pressure
PN 40, Class 300, 20K
-
Medium temperature range
Tantalum: –50 to +150 °C (–58 to +302 °F)
Ziconium: –50 to +200 °C (–58 to +392 °F) -
Ambient temperature range
Standard: –20 to +60 °C (–4 to +140 °F)
Option: –40 to +60 °C (–40 to +140 °F) -
Sensor housing material
1.4301 (304), corrosion resistant
-
Transmitter housing material
Powder‐coated die‐cast aluminium
1.4301 (304), sheet
CF3M (316L), cast -
Degree of protection
IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure
-
Display/Operation
4‐line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible -
Outputs
4 modular outputs:
0‐20 mA (active)/4‐20 mA (active/passive)
Pulse/frequency/switch output (passive)
Relay -
Inputs
2 modular inputs:
Status
0‐20 mA (active)/4‐20 mA (active/passive) -
Digital communication
HART, PROFIBUS PA/DP, FOUNDATION Fieldbus, Modbus RS485, EtherNet/IP
-
Power supply
DC 16 to 62 V
AC 85 to 260 V (45 to 65 Hz)
AC 20 to 55 V (45 to 65 Hz) -
Hazardous area approvals
ATEX, IECEx, FM, CSA, NEPSI
-
Other approvals and certificates
3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR, SIL
PED, CRN -
Product safety
CE, C-tick, EAC marking
-
Functional safety
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
-
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
-
Pressure approvals and certificates
PED, CRN
-
Material certificates
3.1 material
-
Measuring principle
Coriolis
-
Characteristic / Application
Balanced single-tube system, "Fit-and-Forget" installation
Design:
Easy to clean, hygienic, careful handling of the medium
- chemically resistant material -
Ambient temperature
-20...+65°C
(-4...+140°F) -
Process temperature
-50...+200°C
(-58...+392°F) -
Process pressure
PN 40
Cl 150...300
JIS 10...20K -
Wetted parts
Zirconium/R60702
-
Output
4...20mA
Pulse/Frequency (10KHz), active/passive
Relays/Status -
Certificates / Approvals
ATEX
FM
CSA
-
Measuring principle
Coriolis
-
Product headline
The chemically resistant single‐tube flowmeter with extended transmitter functionality. Highly accurate measurement of liquids and gases in applications requiring highest corrosion resistance.
-
Sensor features
Maximum safety for chemically aggressive fluids – corrosionresistant wetted parts. Fewer process measuring points –multivariable measurement (flow, density, temperature). Spacesaving installation – no in/outlet run needs. Measuring tube made of Tantalum, Zirconium. Nominal diameter: DN 8 to 50 (³⁄₈ to 2").
-
Transmitter features
Quality – software for filling & dosing, density & concentration, advanced diagnostics. Flexible data transfer options – numerous communication types. Automatic recovery of data for servicing. 4‐ line backlit display with touch control. Device in compact or remote version.
-
Nominal diameter range
DN 8 to 50 (³⁄₈ to 2")
-
Wetted materials
Measuring tube: Tantalum 2.5W; 702 (UNS R60702)
Connection: Tantalum; 702 (UNS R60702) -
Measured variables
Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration
-
Max. measurement error
Mass flow (liquid): ±0.1 %
Volume flow (liquid): ±0.1 %
Mass flow (gas, Tantalum only): ±0.5 %
Density (liquid): ±0.0005 g/cm³ -
Measuring range
0 to 70 000 kg/h (0 to 2570 lb/min)
-
Max. process pressure
PN 40, Class 300, 20K
-
Medium temperature range
Tantalum: –50 to +150 °C (–58 to +302 °F)
Ziconium: –50 to +200 °C (–58 to +392 °F) -
Ambient temperature range
Standard: –20 to +60 °C (–4 to +140 °F)
Option: –40 to +60 °C (–40 to +140 °F) -
Sensor housing material
1.4301 (304), corrosion resistant
-
Transmitter housing material
Powder‐coated die‐cast aluminium
1.4301 (304), sheet
CF3M (316L), cast -
Degree of protection
IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure
-
Display/Operation
4‐line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible -
Outputs
4 modular outputs:
0‐20 mA (active)/4‐20 mA (active/passive)
Pulse/frequency/switch output (passive)
Relay -
Inputs
2 modular inputs:
Status
0‐20 mA (active)/4‐20 mA (active/passive) -
Digital communication
HART, PROFIBUS PA/DP, FOUNDATION Fieldbus, Modbus RS485, EtherNet/IP
-
Power supply
DC 16 to 62 V
AC 85 to 260 V (45 to 65 Hz)
AC 20 to 55 V (45 to 65 Hz) -
Hazardous area approvals
ATEX, IECEx, FM, CSA, NEPSI
-
Product safety
CE, C-tick, EAC marking
-
Functional safety
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
-
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
-
Pressure approvals and certificates
PED, CRN
-
Material certificates
3.1 material
-
-
Tekniske oplysninger (TI)
PROMASS 80/83 I/H Technical
-
Tekniske oplysninger (TI)
Engelsk version - 12/2005New version available in EnglishCoriolis Mass Flow Measuring System , the single-tube system with
fit-and-forget design: easy to clean hygienic minimal shear stress
on fluids.EN DA 01/12/200515/10/2003Sprog:
Engelsk
Version:
01/12/2005
Filstørrelse:
878.5 KB
Filnavn:
TI052DEN.pdf
-
-
-
Tekniske oplysninger (TI)
Proline Promass 80H, 83H Technical Information
-
Tekniske oplysninger (TI)
Engelsk version - 03/2014New version available in EnglishCoriolis flowmeter
The chemically resistant single-tube with a compact or remote
transmitterEN DA 04/03/201416/03/201101/06/201025/01/201001/09/2008Sprog:
Engelsk
Version:
04/03/2014
Filstørrelse:
711.9 KB
Filnavn:
TI00074DEN_1414.pdf
-
-
-
Betjeningsvejledning (BA)
Proline Promass 83 FOUNDATION Fieldbus Operating Instructions
-
Betjeningsvejledning (BA)
Engelsk version - 10/2012New version available in EnglishCoriolis Mass Flow Measuring System (with FOUNDATION Fieldbus
interface) for measuring the mass flow rate, density and temperatureof
fluids and gases.The description of the device functions are in a
separate documentation.EN DA 15/10/201201/10/201108/06/201001/10/200901/11/2008Sprog:
Engelsk
Version:
15/10/2012
Filstørrelse:
2 MB
Filnavn:
BA00065DEN_1412.pdf
-
-
-
Betjeningsvejledning (BA)
Proline Promass 83 PROFIBUS DP/PA Description of Device Functions
-
Betjeningsvejledning (BA)
Engelsk version - 11/2008New version available in EnglishDescription of the device functions (0ptions and inputs). Additional
documentation for Operating Instructions PROline Promass 83 PR
OFIBUS-DP/-PA.EN DA 01/11/200801/01/200601/03/200501/06/2001Sprog:
Engelsk
Version:
01/11/2008
Filstørrelse:
1.9 MB
Filnavn:
BA064DEN_1108.pdf
-
-
-
Betjeningsvejledning (BA)
Proline Promass 83 FOUNDATION Fieldbus Device Functions
-
Betjeningsvejledning (BA)
Engelsk version - 11/2008New version available in EnglishDescription of the device functions (0ptions and inputs). Additional
documentation for Operating Instructions PROline Promass 83 FOUNDATION
Fieldbus.EN DA 01/11/200801/12/200601/12/200501/12/2000Sprog:
Engelsk
Version:
01/11/2008
Filstørrelse:
1.5 MB
Filnavn:
BA066DEN_1108.pdf
-
-
-
Betjeningsvejledning (BA)
Proline Promass 83 MODBUS RS485 Description of Device Functions
-
Betjeningsvejledning (BA)
Engelsk version - 11/2008New version available in EnglishDescriptions of the device functions (Options and In-/Outputs)
Additional documentation for Operating Instructions Promass 83 MODBUS
RS485.EN DA 01/11/200801/12/200501/11/2004Sprog:
Engelsk
Version:
01/11/2008
Filstørrelse:
1.8 MB
Filnavn:
BA108DEN_1108.pdf
-
-
-
Betjeningsvejledning (BA)
Proline Promass 83 HART Operating Instructions
-
Betjeningsvejledning (BA)
Engelsk version - 12/2014New version available in EnglishCoriolis flowmeter
EN DA 01/12/201415/10/201201/10/201101/03/201001/10/2008Sprog:
Engelsk
Version:
01/12/2014
Filstørrelse:
2.3 MB
Filnavn:
BA00059DEN_1514.pdf
-
-
-
Betjeningsvejledning (BA)
Proline Promass 83 HART Description of Device Functions
-
Betjeningsvejledning (BA)
Engelsk version - 12/2014New version available in EnglishCoriolis flowmeter
EN DA 01/12/201401/09/200801/12/200501/11/200415/10/2003Sprog:
Engelsk
Version:
01/12/2014
Filstørrelse:
1.3 MB
Filnavn:
BA00060DEN_1314.pdf
-
-
-
Betjeningsvejledning (BA)
Proline Promass 83 Modbus RS485 Operating Instructions
-
Betjeningsvejledning (BA)
Engelsk version - 10/2012New version available in EnglishCoriolis Mass Flow Measuring System (with Modbus RS485
interface) for measuring the mass flow rate, density and temperature of
fluids and gases.The description of the device functions are in a
separate documentation.EN DA 15/10/201201/10/201108/06/201001/11/200801/12/2006Sprog:
Engelsk
Version:
15/10/2012
Filstørrelse:
2.5 MB
Filnavn:
BA00107DEN_1412.pdf
-
-
-
Betjeningsvejledning (BA)
Proline Promass 83 PROFIBUS DP/PA Operating Instructions
-
Betjeningsvejledning (BA)
Engelsk version - 10/2012New version available in EnglishCoriolis Mass Flow Measuring System (with PROFIBUS DP/PA interface)
for measuring the mass flow rate, density and temperature of fluids and
gases. The description of the device functions are in a separate
documentation.EN DA 15/10/201201/10/201108/06/201001/11/200801/08/2007Sprog:
Engelsk
Version:
15/10/2012
Filstørrelse:
3.6 MB
Filnavn:
BA00063DEN_1412.pdf
-