Dette produkt er ikke længere tilgængeligt.
Se den nye generation i afsnittet med forgængere/efterfølgere, eller kontakt den lokale Endress+Hauser-afdeling.
-
Afløser
-
Standardprodukter
- Pålidelige og robuste med lav vedligeholdelse
Teknisk ydeevne
Enkelhed
-
Specialiserede produkter
- Designet til krævende applikationer
Teknisk ydeevne
Enkelhed
Variabel
FLEX valg Teknisk ydeevne Enkelhed - F
- L
- E
- X
Fundamental
Få dækket dine basale målebehov
Teknisk ydeevne Enkelhed - F
- L
- E
- X
Lean
Administrer nemt dine kerneprocesser
Teknisk ydeevne Enkelhed - F
- L
- E
- X
Extended
Optimer dine processer med innovative teknologier
Teknisk ydeevne Enkelhed - F
- L
- E
- X
Xpert
Til de mest udfordrende applikationer
Teknisk ydeevne Enkelhed Variabel
-
-
Measuring principle
Coriolis
-
Product headline
The specialist for life sciences with extended transmitter functionality. Dedicated for applications under sterile conditions in the life sciences industry.
-
Sensor features
Highest process quality – fully compliant to industry requirements. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in/outlet run needs. ASME BPE, 3-A and EHEDG conform & low delta ferrite. Electropolished measuring tube in 1.4435 (316L).
-
Transmitter features
Quality – software for filling & dosing, density & concentration, advanced diagnostics. Flexible data transfer options – numerous communication types. Automatic recovery of data for servicing. 4‐line backlit display with touch control. Device in compact or remote version.
-
Nominal diameter range
DN 8 to 50 (⅜ to 2")
-
Wetted materials
Measuring tube: 1.4435 (316L)
Connection: 1.4435 (316L); 1.4404 (316/316L) -
Measured variables
Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration
-
Max. measurement error
Mass flow (liquid): ±0.1 %
Volume flow (liquid): ±0.1 %
Mass flow (gas): ±0.5 %
Density (liquid): ±0.0005 g/cm³ -
Measuring range
0 to 70 000 kg/h (0 to 2570 lb/min)
-
Max. process pressure
PN 63, Class 300, 40K
-
Medium temperature range
–50 to +200 °C (–58 to +392 °F)
-
Ambient temperature range
Standard: –20 to +60 °C (–4 to +140 °F)
Option: –40 to +60 °C (–40 to +140 °F) -
Sensor housing material
1.4301 (304), corrosion resistant
-
Transmitter housing material
Powder‐coated die‐cast aluminium
1.4301 (304), sheet
CF3M (316L), cast -
Degree of protection
IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure
-
Display/Operation
4‐line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible -
Outputs
4 modular outputs:
0‐20 mA (active)/4‐20 mA (active/passive)
Pulse/frequency/switch output (passive)
Relay -
Inputs
2 modular inputs:
Status
0‐20 mA (active)/4‐20 mA (active/passive) -
Digital communication
HART, PROFIBUS PA/DP, FOUNDATION Fieldbus, Modbus
RS485, EtherNet/IP -
Power supply
DC 16 to 62 V
AC 85 to 260 V (45 to 65 Hz)
AC 20 to 55 V (45 to 65 Hz) -
Hazardous area approvals
ATEX, IECEx, FM, CSA, NEPSI
-
Other approvals and certificates
3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR, SIL
PED, CRN
3-A, FDA, ASME BPE, ISPE -
Product safety
CE, C-tick, EAC marking
-
Functional safety
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
-
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
-
Pressure approvals and certificates
PED, CRN
-
Material certificates
3.1 material
-
Hygienic approvals and certificates
3-A, FDA, ASME BPE, ISPE
-
Measuring principle
Coriolis
-
Product headline
The specialist for life sciences with extended transmitter functionality. Dedicated for applications under sterile conditions in the life sciences industry.
-
Sensor features
Highest process quality – fully compliant to industry requirements. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in/outlet run needs. ASME BPE and 3-A conform & low delta ferrite. Electropolished measuring tube in 1.4435 (316L).
-
Transmitter features
Quality – software for filling & dosing, density & concentration, advanced diagnostics. Flexible data transfer options – numerous communication types. Automatic recovery of data for servicing. 4‐line backlit display with touch control. Device in compact or remote version.
-
Nominal diameter range
DN 8 to 50 (⅜ to 2")
-
Wetted materials
Measuring tube: 1.4435 (316L)
Connection: 1.4435 (316L); 1.4404 (316/316L) -
Measured variables
Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration
-
Max. measurement error
Mass flow (liquid): ±0.1 %
Volume flow (liquid): ±0.1 %
Mass flow (gas): ±0.5 %
Density (liquid): ±0.0005 g/cm³ -
Measuring range
0 to 70 000 kg/h (0 to 2570 lb/min)
-
Max. process pressure
PN 63, Class 300, 40K
-
Medium temperature range
–50 to +200 °C (–58 to +392 °F)
-
Ambient temperature range
Standard: –20 to +60 °C (–4 to +140 °F)
Option: –40 to +60 °C (–40 to +140 °F) -
Sensor housing material
1.4301 (304), corrosion resistant
-
Transmitter housing material
Powder‐coated die‐cast aluminium
1.4301 (304), sheet
CF3M (316L), cast -
Degree of protection
IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure
-
Display/Operation
4‐line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible -
Outputs
4 modular outputs:
0‐20 mA (active)/4‐20 mA (active/passive)
Pulse/frequency/switch output (passive)
Relay -
Inputs
2 modular inputs:
Status
0‐20 mA (active)/4‐20 mA (active/passive) -
Digital communication
HART, PROFIBUS PA/DP, FOUNDATION Fieldbus, Modbus
RS485, EtherNet/IP -
Power supply
DC 16 to 62 V
AC 85 to 260 V (45 to 65 Hz)
AC 20 to 55 V (45 to 65 Hz) -
Hazardous area approvals
ATEX, IECEx, FM, CSA, NEPSI
-
Other approvals and certificates
3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR, SIL
PED, CRN
3-A, FDA, ASME BPE, ISPE -
Product safety
CE, C-tick, EAC marking
-
Functional safety
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
-
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
-
Pressure approvals and certificates
PED, CRN
-
Material certificates
3.1 material
-
Hygienic approvals and certificates
3-A, FDA, ASME BPE, ISPE
-
Measuring principle
Coriolis
-
Characteristic / Application
Coriolis mass flowmeter complying with ASME BPE, ISPE, FDA, 3-A
-
Ambient temperature
-20...+65°C
(-4...+140°F) -
Process temperature
-50...+200°C
(-58...+392°F) -
Process pressure
PN 16...40
Cl 150...300
JIS 20...40K -
Wetted parts
316L/1.4435
-
Output
4...20mA
Pulse/Frequency (10KHz, active/passive)
Relays/Status -
Certificates / Approvals
ATEX
FM
CSA IECEx TIIS NEPSI
-
Measuring principle
Coriolis
-
Product headline
The specialist for life sciences with extended transmitter functionality. Dedicated for applications under sterile conditions in the life sciences industry.
-
Sensor features
Highest process quality – fully compliant to industry requirements. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in/outlet run needs. ASME BPE, 3-A and EHEDG conform & low delta ferrite. Electropolished measuring tube in 1.4435 (316L).
-
Transmitter features
Quality – software for filling & dosing, density & concentration, advanced diagnostics. Flexible data transfer options – numerous communication types. Automatic recovery of data for servicing. 4‐line backlit display with touch control. Device in compact or remote version.
-
Nominal diameter range
DN 8 to 50 (⅜ to 2")
-
Wetted materials
Measuring tube: 1.4435 (316L)
Connection: 1.4435 (316L); 1.4404 (316/316L) -
Measured variables
Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration
-
Max. measurement error
Mass flow (liquid): ±0.1 %
Volume flow (liquid): ±0.1 %
Mass flow (gas): ±0.5 %
Density (liquid): ±0.0005 g/cm³ -
Measuring range
0 to 70 000 kg/h (0 to 2570 lb/min)
-
Max. process pressure
PN 63, Class 300, 40K
-
Medium temperature range
–50 to +200 °C (–58 to +392 °F)
-
Ambient temperature range
Standard: –20 to +60 °C (–4 to +140 °F)
Option: –40 to +60 °C (–40 to +140 °F) -
Sensor housing material
1.4301 (304), corrosion resistant
-
Transmitter housing material
Powder‐coated die‐cast aluminium
1.4301 (304), sheet
CF3M (316L), cast -
Degree of protection
IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure
-
Display/Operation
4‐line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible -
Outputs
4 modular outputs:
0‐20 mA (active)/4‐20 mA (active/passive)
Pulse/frequency/switch output (passive)
Relay -
Inputs
2 modular inputs:
Status
0‐20 mA (active)/4‐20 mA (active/passive) -
Digital communication
HART, PROFIBUS PA/DP, FOUNDATION Fieldbus, Modbus
RS485, EtherNet/IP -
Power supply
DC 16 to 62 V
AC 85 to 260 V (45 to 65 Hz)
AC 20 to 55 V (45 to 65 Hz) -
Hazardous area approvals
ATEX, IECEx, FM, CSA, NEPSI
-
Product safety
CE, C-tick, EAC marking
-
Functional safety
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
-
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
-
Pressure approvals and certificates
PED, CRN
-
Material certificates
3.1 material
-
Hygienic approvals and certificates
3-A, FDA, ASME BPE, ISPE
-
-
Tekniske oplysninger (TI)
Proline Promass 80P, 83P Technical Information
-
Tekniske oplysninger (TI)
Engelsk version - 04/2015New version available in EnglishThe specialist for life sciences with extended transmitter functionality
EN DA 01/04/201515/12/201005/11/201025/01/201009/07/2009Sprog:
Engelsk
Version:
01/04/2015
Filstørrelse:
1.4 MB
Filnavn:
TI00078DEN_1415.pdf
-
-
-
Betjeningsvejledning (BA)
Proline Promass 83 FOUNDATION Fieldbus Operating Instructions
-
Betjeningsvejledning (BA)
Engelsk version - 10/2012New version available in EnglishCoriolis Mass Flow Measuring System (with FOUNDATION Fieldbus
interface) for measuring the mass flow rate, density and temperatureof
fluids and gases.The description of the device functions are in a
separate documentation.EN DA 15/10/201201/10/201108/06/201001/10/200901/11/2008Sprog:
Engelsk
Version:
15/10/2012
Filstørrelse:
2 MB
Filnavn:
BA00065DEN_1412.pdf
-
-
-
Betjeningsvejledning (BA)
Proline Promass 83 PROFIBUS DP/PA Description of Device Functions
-
Betjeningsvejledning (BA)
Engelsk version - 11/2008New version available in EnglishDescription of the device functions (0ptions and inputs). Additional
documentation for Operating Instructions PROline Promass 83 PR
OFIBUS-DP/-PA.EN DA 01/11/200801/01/200601/03/2005Sprog:
Engelsk
Version:
01/11/2008
Filstørrelse:
1.9 MB
Filnavn:
BA064DEN_1108.pdf
-
-
-
Betjeningsvejledning (BA)
Proline Promass 83 FOUNDATION Fieldbus Device Functions
-
Betjeningsvejledning (BA)
Engelsk version - 11/2008New version available in EnglishDescription of the device functions (0ptions and inputs). Additional
documentation for Operating Instructions PROline Promass 83 FOUNDATION
Fieldbus.EN DA 01/11/200801/12/200601/12/200501/12/2000Sprog:
Engelsk
Version:
01/11/2008
Filstørrelse:
1.5 MB
Filnavn:
BA066DEN_1108.pdf
-
-
-
Betjeningsvejledning (BA)
Proline Promass 83 HART Description of Device Functions
-
Betjeningsvejledning (BA)
Engelsk version - 12/2014New version available in EnglishCoriolis flowmeter
EN DA 01/12/201401/09/200801/12/200501/11/2004Sprog:
Engelsk
Version:
01/12/2014
Filstørrelse:
1.3 MB
Filnavn:
BA00060DEN_1314.pdf
-
-
-
Betjeningsvejledning (BA)
Proline Promass 83 HART Operating Instructions
-
Betjeningsvejledning (BA)
Engelsk version - 12/2014New version available in EnglishCoriolis flowmeter
EN DA 01/12/201415/10/201201/10/201101/03/201001/10/2008Sprog:
Engelsk
Version:
01/12/2014
Filstørrelse:
2.3 MB
Filnavn:
BA00059DEN_1514.pdf
-
-
-
Betjeningsvejledning (BA)
Proline Promass 83
-
Betjeningsvejledning (BA)
Russisk version - 10/2011New version available in EnglishРуководство по эксплуатации для расходомеров с выходным
сигналом MODBUS RS485.Sprog:
Russisk
Version:
01/10/2011
Filstørrelse:
4.2 MB
Filnavn:
BA00107DRU_1311.pdf
-
-
-
Betjeningsvejledning (BA)
Proline Promass 83 PROFIBUS DP/PA Operating Instructions
-
Betjeningsvejledning (BA)
Engelsk version - 10/2012New version available in EnglishCoriolis Mass Flow Measuring System (with PROFIBUS DP/PA interface)
for measuring the mass flow rate, density and temperature of fluids and
gases. The description of the device functions are in a separate
documentation.EN DA 15/10/201201/10/201108/06/201001/11/200801/08/2007Sprog:
Engelsk
Version:
15/10/2012
Filstørrelse:
3.6 MB
Filnavn:
BA00063DEN_1412.pdf
-
-
-
Kort anvisning (KA)
Proline Promass 83 Brief Operating Instructions
-
Kort anvisning (KA)
Engelsk version - 05/2016New version available in EnglishCoriolis flowmeter
EN DA 26/05/201606/08/201515/10/201201/10/201101/03/2011Sprog:
Engelsk
Version:
26/05/2016
Filstørrelse:
2 MB
Filnavn:
KA00024DEN_1716.pdf
-
-
-
Installationsanvisninger (EA)
EA Replacing cover and O-ring
-
Installationsanvisninger (EA)
Engelsk version - 10/2024New version available in EnglishProline 10, 23, 50, 51, 53, 55, 400, 800, 40, 80, 83, 84, 8ME, 8FF, 8FE
,8CM, 90, 91, 92, 93, 65, 72, 73EN DA 15/10/202401/10/2018Sprog:
Engelsk
Version:
15/10/2024
Filstørrelse:
797.3 KB
Filnavn:
EA00098DA2_1624-00.pdf
-