Oversigt over specifikationer
-
Measuring range
0.05 to 2 mg/l Fe
0.1 to 5 mg/l Fe
0.1 to 5 mg/l with dilution function to maximum 2.0 to 100 mg/l Fe -
Process temperature
4 to 40 °C (39.2 to 104 °F)
-
Process pressure
At atmospheric pressure, < 0.2 bar
Anvendelsesområde
Liquiline System CA80FE offers precise, regulation-compliant online measurement. It supports you in controlling the iron content of drinking water, mineral water or source water for industrial processes. Like all Liquiline System analyzers, it enables plug & play of up to four Memosens sensors – minimizing the installation effort. Automatic calibration and cleaning and the low reagent consumption reduce operating costs while advanced diagnostics with remote access ensure process safety.
Liquiline System CA80FE monitors:
Iron content in drinking water and mineral water
Residual iron after precipitation, flocculation and filtration processes
Process water containing diluted iron
Fordele
Compliance with standard ferrozine method ensures direct comparability to lab measurements
Supports predictive maintenance by advanced diagnostics
Reduced operating costs through automatic calibration and cleaning as well as low reagent consumption
Easy upgrade of functionality - even to a complete measuring station - simply by adding modules and connecting Memosens sensors.
Comfortable remote access via integrated web server
Seamless integration into process control systems thanks to digital field busses such as Modbus, PROFIBUS or EtherNet/IP
Drive connectivity: Liquiline Edge Module CYY7 transfers process data to Netilion, independently of the fieldbus. This allows remote overview and the use of IIoT services. It’s available in new products or as upgrade to installed Liquiline platforms.
Videoer
-
Iron concentration in a liquid can be measured using the colorimetric measuring principle. This video shows what it is about and how this measuring principle works.
-
Standardprodukter
- Pålidelige og robuste med lav vedligeholdelse
Teknisk ydeevne
Enkelhed
-
Specialiserede produkter
- Designet til krævende applikationer
Teknisk ydeevne
Enkelhed
Variabel
| FLEX valg | Teknisk ydeevne | Enkelhed |
|---|---|---|
Fundamental Få dækket dine basale målebehov |
Teknisk ydeevne
|
Enkelhed
|
Lean Administrer nemt dine kerneprocesser |
Teknisk ydeevne
|
Enkelhed
|
Extended Optimer dine processer med innovative teknologier |
Teknisk ydeevne
|
Enkelhed
|
Xpert Til de mest udfordrende applikationer |
Teknisk ydeevne
|
Enkelhed
Variabel |
Forgænger
-
Measuring principle
Colorimetric
-
Characteristic
Process analyzer for iron in aqueous solutions
Comply with standard colorimetric measuring principle, ferrozine method -
Size
Housing (open version):
793 x 530 x 417 mm
31.22 x 20.87 x 16.42 in
Housing (closed version):
793 x 530 x 463 mm
31.22 x 20.87 x 18.23 in
Housing with base:
1723 x 530 x 463 mm
67.83 x 20.87 x 18.23 in -
Design
Open design, cabinet and stand housing
High-Performance plastic ASA-PC, additional stand coated steel -
Process temperature
4 to 40 °C (39.2 to 104 °F)
-
Ambient temperature
5 to 40 °C (41 to 104 °F)
Outdoor version: - 20 to 40 °C (-4 to 104 °F) -
Process pressure
At atmospheric pressure, < 0.2 bar
-
Sample flow rate
Min. 5 ml/min (0.17 fl.oz/min)
-
Consistency of the sample
Suspended solids content
Turbitity < 50 NTU, aqueous, homogenized -
Application
Monitoring of the iron content of potable water, mineral water and source water for industrial processes
-
Power supply
100 to 120 VAC / 200 to 240 VAC ± 10%
24 VDC ± 10%
50 ± 1 or 60 ± 1,2 Hz -
Output / communication
2x 0/4 to 20 mA
Webserver, Modbus, Ethernet/IP, Profibus DP -
Input
1 or 2 measuring channel
1 to 4 digital sensor inputs for sensors with Memosens protocol (optional) -
Measuring range
0.05 to 2 mg/l Fe
0.1 to 5 mg/l Fe
0.1 to 5 mg/l with dilution function to maximum 2.0 to 100 mg/l Fe -
Consumables
Reagents and standard solutions CY80FE for the operation
Regular maintenance is done with the parts of the maintenance kit CAV800
-
-
Tekniske oplysninger (TI)
TI Liquiline System CA80FE
-
Tekniske oplysninger (TI)
Engelsk version - 05/2024New version available in EnglishColorimetric analyzer for iron
EN DA 23/05/202430/11/202213/07/202119/02/202009/06/2017Sprog:
Engelsk
Version:
23/05/2024
Filstørrelse:
4.3 MB
Filnavn:
TI01291CEN_0624-00.pdf
-
-
-
Betjeningsvejledning (BA)
Memosens
-
Betjeningsvejledning (BA)
Engelsk version - 05/2022New version available in EnglishSensor inputs with Memosens protocol
EN DA 30/05/202228/02/2019Sprog:
Engelsk
Version:
30/05/2022
Filstørrelse:
3.3 MB
Filnavn:
BA01245CEN_0822-00.pdf
-
-
-
Betjeningsvejledning (BA)
BA Liquiline System CA80FE
-
Betjeningsvejledning (BA)
Engelsk version - 05/2024New version available in EnglishColorimetric analyzer for iron
EN DA 23/05/202430/11/202213/07/202113/01/202009/06/2017Sprog:
Engelsk
Version:
23/05/2024
Filstørrelse:
6.6 MB
Filnavn:
BA01586CEN_0624-00.pdf
-
-
-
Kort anvisning (KA)
Liquiline System CA80FE
-
Kort anvisning (KA)
Dansk version - 05/2021New version available in EnglishKolorimetrisk analysator til jern
EN DA 31/05/202119/02/202006/10/201707/04/201715/03/2016Sprog:
Dansk
Version:
31/05/2021
Filstørrelse:
3.3 MB
Filnavn:
KA01237CDA_0521.pdf
-
-
-
Installationsanvisninger (EA)
Kit CM44x/CSXxx/CA80XX
-
Installationsanvisninger (EA)
Engelsk version - 11/2022New version available in EnglishModule 485MB or 485DP
For Ethernet configuration, PROFIBUS DP, Modbus RS485EN DA 28/11/2022Sprog:
Engelsk
Version:
28/11/2022
Filstørrelse:
1.8 MB
Filnavn:
EA01447CEN_0122-00.pdf
-
-
-
Installationsanvisninger (EA)
Kits for Analyzer CA80: Engineering parts
-
Installationsanvisninger (EA)
Engelsk version - 06/2025New version available in EnglishKits for Analyzer CA80: Engineering parts
EN DA 30/06/2025Sprog:
Engelsk
Version:
30/06/2025
Filstørrelse:
2.1 MB
Filnavn:
71223028 Anleitung Kits CA8x Verfahrenstechnik 2022-08.pdf
-
-
-
Installationsanvisninger (EA)
Einbauanleitung/ Installation Instructions Kit Module/Modules
-
Installationsanvisninger (EA)
Engelsk version - 07/2014New version available in EnglishFür erweiterte Funktionalität
For extended functionalityEN DA 07/07/201425/03/201331/12/2011Sprog:
Engelsk
Version:
07/07/2014
Filstørrelse:
2.4 MB
Filnavn:
EA00008CA2_0314.pdf
-
-
-
Installationsanvisninger (EA)
Kit for analyzer CA8x: Valve
-
Installationsanvisninger (EA)
Engelsk version - 07/2025New version available in EnglishThis instruction applies to following spare part kit:
71218433 Kit CA8x: ValveEN DA 24/07/202509/05/2025Sprog:
Engelsk
Version:
24/07/2025
Filstørrelse:
2.1 MB
Filnavn:
71231926 Anleitung Kit CA80 Ventil 2025-07.pdf
-
-
-
Installationsanvisninger (EA)
Kits for Analyzer CA8x: Housing parts
-
Installationsanvisninger (EA)
Engelsk version - 03/2025New version available in EnglishInstallation instruction: Kits for Analyzer CA8x: Housing parts
EN DA 03/03/2025Sprog:
Engelsk
Version:
03/03/2025
Filstørrelse:
957.4 KB
Filnavn:
71223031 Anleitung Kits CA8x Gehaeuseteile 2022-06.pdf
-
-
-
Installationsanvisninger (EA)
Kit manual for CAV800: Maintenance
-
Installationsanvisninger (EA)
Engelsk version - 05/2025New version available in EnglishKits for analyzer CA80: Maintenance kit CAV800
EN DA 09/05/2025Sprog:
Engelsk
Version:
09/05/2025
Filstørrelse:
1.9 MB
Filnavn:
71223025 Anleitung Kits CAV800 Wartung 2025-05.pdf
-
Vælg blandt de foreslåede muligheder
-
-- selected coding-- selected label99.999,00<%label%>
-
Leder du efter flere indstillinger? Anvend den individuelle konfigurator for at fortsætte.
-
-- selected coding-- selected label99.999,00<%feature%>
-
<%label%>99.999,00
-
Leder du efter flere indstillinger? Anvend den individuelle konfigurator for at fortsætte.
-
Process Connection
-
<%label%>99.999,00
-
<%label%>99.999,00
-
-
<%feature%><%coding%><%label%>
- CAD-tegninger CAD-tegninger
- CAD-tegninger
-
Pris pr. enhed
-
<%range%><%price%>
-
- Valgfrie tilføjelser
Individuel konfiguration
Ofte købt sammen
Tilbehør
Relaterede produkter