Rod probe: +/- 2 mm (0.08 in) Rope probe <= 15 m (49 ft): +/- 2 mm (0.08 in) Rope probe > 15 m (49 ft): +/- 10 mm (0.39 in) Coaxial probe: +/- 2 mm (0.08 in)
Process temperature
XT: -196...+280 °C (-321...+536 °F) HT: -196...+450 °C (-321...+842 °F)
Process pressure / max. overpressure limit
Vacuum...400 bar (Vacuum...5800 psi)
Max. measurement distance
Rod: 10 m (33 ft) Min DK>1.6 Rope: 25 m...30 m (82 ft...98 ft) Min DK>1.6; 30 m...45 m (98 ft...148 ft) Min DK >1,9 Coaxial probe: 6 m (20 ft) Min DK>1.4
Levelflex FMP54 for continuous level measurement in liquids under extreme conditions. The process connection with its ceramic-graphite seal safeguards high temperature and high pressure applications as they occur in steam boilers and toxic media like ammonia. The gas tight feedthrough guarantees additional safety. Only the gas phase compensation of the FMP54 gives reliable results in case of gas and steam phases. Reliable measurement in case of moving surface and foam or in changing medias.
Version with rod, rope or coax probe.
Process connections: Thread or flange
Temperature: -196 to +450°C (-320 to +842°F)
Pressure: -1 to +400bar (-14.5 to +5,800psi)
Maximum measuring range: Rod 10m (33ft), rope 45m (148ft), coax 6m (20ft)
Protolaunch anvender flowmålere og niveausensorer fra Endress+Hauser på et testanlæg for raketfremdrift i Buckinghamshire for at demonstrere fremdriftssystemernes og komponenternes ydeevne.
Messer producerer brint i en dampreformer. Anlægget har et stort antal beskyttelses- og sikkerhedsanordninger, hvor trykværdier spiller en vigtig rolle.
Den egyptiske regering arbejder på at udskifte flydende brændstoffer med naturgas. For at opnå dette stræber de efter et stadigt stigende antal CNG-stationer i deres land fra 306 til 1.000 ved udgangen af 2021.
Premium device high pressure/ high temperature Rod probe, Rope probe, Coaxial Probe Integrated data memory, Factory precalibrated, Reliable measuring: in case of moved surface + foam, for changing medias
Interface measurement
Clean interfaces liquid/ liquid; Simultaneous measurement of interface and overall level
Specialities
Heartbeat Technology, Bluetooth® commissioning, Operation and maintenance SmartBlue App, HistoROM, RFID TAG for easy identification
Supply / Communication
2-wire (HART / PROFIBUS PA/ FOUNDATION Fieldbus) 4-wire (HART) Bluetooth® wireless technology and App (optional)
Accuracy
Rod probe: +/- 2 mm (0.08 in) Rope probe <= 15 m (49 ft): +/- 2 mm (0.08 in) Rope probe > 15 m (49 ft): +/- 10 mm (0.39 in) Coaxial probe: +/- 2 mm (0.08 in)
Ambient temperature
-50...+80 °C (-58...+176 °F)
Process temperature
XT: -196...+280 °C (-321...+536 °F) HT: -196...+450 °C (-321...+842 °F)
Thread: G 1 1/2, MNPT 1 1/2 Flange: ASME 2"...4", DN50...DN100, JIS 10K, 63K, Fisher Masoneilan
Sensor length
Rod probe: 10 m (33 ft) Rope probe: 45 m (148 ft) Coaxial probe: 6 m (20 ft)
Max. measurement distance
Rod: 10 m (33 ft) Min DK>1.6 Rope: 25 m...30 m (82 ft...98 ft) Min DK>1.6; 30 m...45 m (98 ft...148 ft) Min DK >1,9 Coaxial probe: 6 m (20 ft) Min DK>1.4
Communication
4...20 mA HART PROFIBUS PA FOUNDATION Fieldbus Bluetooth® wireless technology
Certificates / Approvals
ATEX, FM, CSA C/US, IEC Ex, INMETRO, NEPSI, KC, EAC, JPN Ex, UK Ex
Active barrier, 1 channel for 4 to 20 mA, HART® transparent with 24 to 230 V AC/DC as well as active/passive input and output, optionally with SIL and Ex
Active barrier, 1 channel for 4 to 20 mA, HART® transparent with 24 to 230 V AC/DC as well as active/passive input and output, optionally with SIL and Ex
Active barrier, 1 channel for 4 to 20 mA, HART® transparent with 24 to 230 V AC/DC as well as active/passive input and output, optionally with SIL and Ex