Oversigt over specifikationer
-
Accuracy
Standard acc. to ASTM E-230
Special acc. to ASTM E-230 -
Response time
63% rt = 1 s
-
Max. process pressure (static)
not applicable
-
Operating temperature range
Type T:
-270 °C ...400 °C
(-454 °F ...752 °F)
Type J:
-210 °C ...1200 °C
(-346 °F ...2.192 °F)
Type E:
-270 °C ...1.000 °C
(-454 °F ...1.832 °F)
Type K:
-270 °C ...1.372 °C
(-454 °F ...2.500 °F)
Type N:
-270 °C ...1.300 °C
(-454 °F ...2.372 °F) -
Max. immersion length on request
up to 100" (2540 mm)
others on request
Anvendelsesområde
The high modular thermometer is used for several applications with harsh environments, e.g. in Power Plants, Refineries or in the Chemical or Petrochemical industry. The robust device is designed for use within an existing thermowell. With different head transmitter it's a complete unit ready for use with enhanced measurement accuracy and reliability.
The sensor assembly can be used in process industries such as:
Chemicals
Petrochemical
Refineries
Offshore Platforms
Fordele
FM/CSA XP Class I, Div. 1 approved temperature assemblies for maximum safety
One source shopping for temperature measurement solutions. World class transmitter with integrated sensor offering for heavy process industry applications
Remove and install straight out of the box!
Improved galvanic isolation on most devices (2 kV)
Simplified model structure: Competitively priced, offers great value. Easy to order and reorder. A single model number includes sensor, thermowell and transmitter assembly for a complete point solution
All iTEMP® transmitters provide long term stability ≤0.05% per year
-
Standardprodukter
- Pålidelige og robuste med lav vedligeholdelse
Teknisk ydeevne
Enkelhed
-
Specialiserede produkter
- Designet til krævende applikationer
Teknisk ydeevne
Enkelhed
Variabel
| FLEX valg | Teknisk ydeevne | Enkelhed |
|---|---|---|
Fundamental Få dækket dine basale målebehov |
Teknisk ydeevne
|
Enkelhed
|
Lean Administrer nemt dine kerneprocesser |
Teknisk ydeevne
|
Enkelhed
|
Extended Optimer dine processer med innovative teknologier |
Teknisk ydeevne
|
Enkelhed
|
Xpert Til de mest udfordrende applikationer |
Teknisk ydeevne
|
Enkelhed
Variabel |
-
Measuring principle
Thermocouple
-
Characteristic / Application
Explosion Proof US style
modular temperature assembly
for heavy duty applications
with extension
to be used with existing thermowell -
Thermowell / protection tube
to use with thermowell
-
Insert / probe
mineral insulated (MI), flexible
-
Outer diameter protection tube / Insert
1/4'' (6,35 mm)
3/8'' (9,53 mm) -
Max. immersion length on request
up to 100" (2540 mm)
others on request -
Material protection tube/ thermowell
Sensor sheath
316
Alloy 600 -
Optional coating
not applicable
-
Process connection
Thermowell connection
male thread:
NPT1/2" -
Tip shape
straight
-
Surface roughness Ra
not applicable
-
Operating temperature range
Type T:
-270 °C ...400 °C
(-454 °F ...752 °F)
Type J:
-210 °C ...1200 °C
(-346 °F ...2.192 °F)
Type E:
-270 °C ...1.000 °C
(-454 °F ...1.832 °F)
Type K:
-270 °C ...1.372 °C
(-454 °F ...2.500 °F)
Type N:
-270 °C ...1.300 °C
(-454 °F ...2.372 °F) -
Max. process pressure (static)
not applicable
-
Accuracy
Standard acc. to ASTM E-230
Special acc. to ASTM E-230 -
Response time
63% rt = 1 s
-
Integration head transmitter
yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
-
Ex - approvals
FM XP
CSA XP
FM/CSA XP
CSA GP -
Certification
SIL (transmitter only)
-
-
Tekniske oplysninger (TI)
T53, T54 and T55
-
Tekniske oplysninger (TI)
Engelsk version - 01/2023New version available in EnglishExplosion proof thermocouple assemblies in thermowells with spring
loaded insert and enclosure for process industryEN DA 27/01/202314/01/2021Sprog:
Engelsk
Version:
27/01/2023
Filstørrelse:
1.3 MB
Filnavn:
TI00127REN_1623-00.pdf
-
-
-
Kort anvisning (KA)
T55 Compact Instructions
-
Kort anvisning (KA)
Engelsk version - 12/2012New version available in EnglishExplosion proof thermocouple assembly
Sprog:
Engelsk
Version:
01/12/2012
Filstørrelse:
567.5 KB
Filnavn:
KA00245rae_1312.pdf
-
-
-
Certifikater, FM/CSA (ZD)
Control Drawing FM XP, NI, DIP T15, T55, TU211, TU221
-
Certifikater, FM/CSA (ZD)
Engelsk version - 11/2020New version available in EnglishTemperature Process RTD Explosion Proof T15, Process TC Explosion
Proof
T55, RTD insert TU211, TC insert TU221
Installation Notesfor Hazardous LocationsSprog:
Engelsk
Version:
24/11/2020
Filstørrelse:
66.6 KB
Filnavn:
160100120.pdf
-
-
-
Certifikater, FM/CSA (ZD)
Temperature assemblies T15, T55 Temperature inserts TU221, TU211 Control drawing FM (XP, DIP)
-
Certifikater, FM/CSA (ZD)
Engelsk version - 11/2011New version available in EnglishInstallation Notes for FM approved apparatus
Sprog:
Engelsk
Version:
01/11/2011
Filstørrelse:
70.5 KB
Filnavn:
160100119.pdf
-
Vælg blandt de foreslåede muligheder
-
-- selected coding-- selected label99.999,00<%label%>
-
Leder du efter flere indstillinger? Anvend den individuelle konfigurator for at fortsætte.
-
-- selected coding-- selected label99.999,00<%feature%>
-
<%label%>99.999,00
-
Leder du efter flere indstillinger? Anvend den individuelle konfigurator for at fortsætte.
-
Process Connection
-
<%label%>99.999,00
-
<%label%>99.999,00
-
-
<%feature%><%coding%><%label%>
- CAD-tegninger CAD-tegninger
- CAD-tegninger
-
Pris pr. enhed
-
<%range%><%price%>
-
- Valgfrie tilføjelser
Individuel konfiguration
Ofte købt sammen
Tilbehør