Prosonic Flow W 400 is the ultrasonic clamp-on flowmeter of choice for safe, cost-effective and maintenance-free measurement of conductive and non-conductive liquids. It measures flow noninvasively and bidirectionally, independent of pressure, density and conductivity, and without process interruption.
FlowDC makes mounting as flexible as never before. The specified accuracy is maintained at an inlet run of only 2 x DN, even in the case of disturbed flow profiles.
Special coupling pads make this ultrasonic clamp-on system maintenance-free during the entire product life cycle.
Heartbeat Technology provides continuous process transparency with its diagnostic, verification and monitoring functions. This way, build-up can be detected before it affects operation.
Fordele
Flexible mounting – FlowDC reduces inlet runs to a minimum
Reliable measurement performance – proven sensors in combination with maintenance-free mounting system deliver long-term stable signals
Low capital investment – cost-effectiveness increases with the pipe diameter (up to DN 4000/160")
User-friendly operation – the web server offers full remote access, while the device’s display offers convenient on-site interaction
Transparent process insights – Heartbeat Technology with its integrated diagnostics, verification and monitoring functions enable compliance and process safety at all times
Videoer
Smart instrumentering via Heartbeat Technology
Ønsker du at give anlæggets ydeevne et boost og reducere omkostningerne? Vores udvalg inden for smart instrumentering med Heartbeat Technology tilbyder dybdegående instrumentindsigt, som sikrer omkostningseffektivitet og driftssikkerhed.
Schluchseewerk AG ønskede at registrere og optimere effektiviteten af sine turbiner på pumpekraftværket i Wehr. Endress+Hauser tilbyder deres optimale løsning med deres clamp-on-ultralydsflowmåler.
Forbes Technologies bygger på instrumenteringsløsninger fra Endress+Hauser til deres røgvaskersystem og i særdeleshed Proline Promag W 10 med 0 x DN fuldboret design og Bluetooth®-tilslutning.
Olin Corporation anvender Proline Promag P 300 til sin elektrolyseproces og drager fordel af præcise målinger under krævende forhold takket være funktionen "Flydende måling".
Protolaunch anvender flowmålere og niveausensorer fra Endress+Hauser på et testanlæg for raketfremdrift i Buckinghamshire for at demonstrere fremdriftssystemernes og komponenternes ydeevne.
Vialit-gruppen fremstiller forskellige produkter til vedligeholdelse af veje. Blanding af halvfabrikata kræver nøjagtig måling af flowhastighed og viskositet. Her leverer Promass I 500 resultater i særklasse.
Clamp-on meter with Heartbeat Technology and web server for the water and wastewater industry. Short inlet run thanks to FlowDC. Bidirectional measurement for water and wastewater as well as process water and hydropower plants.
Sensor features
Low capital investment – cost-effectiveness increases with pipe diameter (up to DN 2000/80"). Long-term stable signal – maintenance-free permanent mounting from outside with coupling pads. Reliable measurement on various pipe materials – sensor for GRP and plastic pipes available. Mounting without process interruption. Wide nominal diameter range: DN 15 to 4000 (½ to 160"). Medium temperature up to +130 °C (+266 °F).
Transmitter features
Safe operation – no need to open the device due to display with touch control, background lighting. Full remote access – web server. Integrated diagnostics, verification and monitoring – Heartbeat Technology. Transmitter housing made of durable polycarbonate or aluminium. Remote version for wall mounting. Integrated data logger: measured values monitoring.
Flowmeter verification for all frequencies except 0.3 MHz, reference line size: 5 MHz DN 50, all other frequencies DN 100 Verification performed on accredited calibration facilities (acc. to ISO/IEC 17025) Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a
0.5 m3/h to 263000 m3/h (2.5gal/min to 1665 Mgal/d)
Medium temperature range
Liner material hard rubber: 0 to +80 °C (+32 to +176 °F) Liner material polyurethane: –20 to +50 °C (–4 to +122 °F) Liner material PTFE: –20 to +90 °C (–4 to +194 °F)
Max. process pressure
PN 40, Class 300, 20K
Wetted materials
Liner material hard rubber: 0 to +80 °C (+32 to +176 °F) Liner material polyurethane: –20 to +50 °C (–4 to +122 °F) Liner material PTFE: –20 to +90 °C (–4 to +194 °F) Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum
0.5 m3/h to 263000 m3/h (2.5gal/min to 1665 Mgal/d)
Medium temperature range
Liner material hard rubber: 0 to +80 °C (+32 to +176 °F) Liner material polyurethane: –20 to +50 °C (–4 to +122 °F) Liner material PTFE: –20 to +90 °C (–4 to +194 °F)
Max. process pressure
PN 40, Class 300, 20K
Wetted materials
Liner material hard rubber: 0 to +80 °C (+32 to +176 °F) Liner material polyurethane: –20 to +50 °C (–4 to +122 °F) Liner material PTFE: –20 to +90 °C (–4 to +194 °F) Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum