Cubemass DCI - The Coriolis flowmeter with backlit display and operation via touch control for measuring smallest quantities of liquids and gases
Cubemass DCI - The Coriolis flowmeter with backlit display and operation via touch control for measuring smallest quantities of liquids and gases
Oversigt over specifikationer
-
Max. measurement error
Mass flow (liquid): ±0.1 %
Volume flow (liquid): ±0.1 %
Mass flow (gas): ±0.5 %
Density (liquid): ±0.0005 g/cm3 -
Measuring range
0 to 1000 kg/h (0 to 37 lb/min)
-
Medium temperature range
–50 to +200 °C (–58 to +392 °F)
-
Max. process pressure
PN 40, Class 300, 10K, 400 bar (5800 psi)
-
Wetted materials
Measuring tube: 1.4539 (904L)
Connection: 1.4539 (904L); 1.4404 (316/316L)
Anvendelsesområde
Cubemass DCI is the proven sensor for the measurement of smallest flow rates in skids, test rigs and industrial robotics, e.g. in applications like lacquering or surface finishing. Neither high pressure nor alternating flow conditions compromise its accuracy. Equipment manufacturers value Cubemass CDI as compact Coriolis sensor with various communication possibilities.
Measuring principle operates independently of physical fluid properties such as viscosity or density
Measuring accurately smallest quantities of liquids and gases
Device properties
Nominal diameter: DN 1 to 6 (1/24 to 1/4")
Process pressure up to 400 bar (5800 psi)
Medium temperature up to +200 °C (+392 °F)
Device as compact or remote version
Flexible outputs
Modbus RS485
Fordele
Measuring accurately smallest quantities of liquids and gases
Space-saving installation – compact single-tube design
Fewer process measuring points – multivariable measurement (flow, density, temperature)
Suitable for skids – lightweight sensor
High flexibility in system integration – wide range of communication interfaces
Fast commissioning – pre-configured devices
Automatic recovery of data for servicing
Videoer
-
The Coriolis Flow Measuring Principle
-
Standardprodukter
- Pålidelige og robuste med lav vedligeholdelse
Teknisk ydeevne
Enkelhed
-
Specialiserede produkter
- Designet til krævende applikationer
Teknisk ydeevne
Enkelhed
Variabel
| FLEX valg | Teknisk ydeevne | Enkelhed |
|---|---|---|
Fundamental Få dækket dine basale målebehov |
Teknisk ydeevne
|
Enkelhed
|
Lean Administrer nemt dine kerneprocesser |
Teknisk ydeevne
|
Enkelhed
|
Extended Optimer dine processer med innovative teknologier |
Teknisk ydeevne
|
Enkelhed
|
Xpert Til de mest udfordrende applikationer |
Teknisk ydeevne
|
Enkelhed
Variabel |
-
Measuring principle
Coriolis
-
Product headline
Compact sensor for smallest quantities with seamless system integration.
Measuring accurately smallest quantities of liquids and gases. -
Sensor features
Space-saving installation – compact single-tube design. Fewer process measuring points – multivariable measurement (flow, density, temperature). Suitable for skids – lightweight sensor.
Nominal diameter: DN 1 to 6 (¹⁄₂₄ to ¹⁄₄"). Process pressure up to 400 bar (5800 psi). Medium temperature up to +200 °C (+392 °F). -
Transmitter features
High flexibility in system integration – wide range of communication interfaces. Fast commissioning – pre-configured devices. Automatic recovery of data for servicing.
Device as compact or remote version. Flexible outputs. Modbus RS485. -
Nominal diameter range
DN 1 to 6 (¹⁄₂₄ to ¹⁄₄")
-
Wetted materials
Measuring tube: 1.4539 (904L)
Connection: 1.4539 (904L); 1.4404 (316/316L) -
Measured variables
Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration
-
Max. measurement error
Mass flow (liquid): ±0.1 %
Volume flow (liquid): ±0.1 %
Mass flow (gas): ±0.5 %
Density (liquid): ±0.0005 g/cm3 -
Measuring range
0 to 1000 kg/h (0 to 37 lb/min)
-
Max. process pressure
PN 40, Class 300, 10K, 400 bar (5800 psi)
-
Medium temperature range
–50 to +200 °C (–58 to +392 °F)
-
Ambient temperature range
Standard: –20 to +60 °C (–4 to +140 °F)
Option: –40 to +60 °C (–40 to +140 °F) -
Sensor housing material
1.4301 (304), corrosion resistant
-
Transmitter housing material
Powder‐coated die‐cast aluminium
-
Degree of protection
IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure
-
Display/Operation
4‐line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible -
Outputs
4 modular outputs:
0‐20 mA (active)/4‐20 mA (active/passive)
Pulse/frequency/switch output (passive), phase‐shifted pulse
Relay -
Inputs
1 modular input: status
-
Digital communication
HART, Modbus RS485
-
Power supply
DC 16 to 62 V
AC 85 to 260 V (45 to 65 Hz)
AC 20 to 55 V (45 to 65 Hz) -
Hazardous area approvals
ATEX, IECEx, NEC/CEC, NEPSI
-
Other approvals and certificates
3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR, SIL
CRN -
Functional safety
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
-
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
-
Material certificates
3.1 material
-
Measuring principle
Coriolis
-
Product headline
Compact sensor for smallest quantities with seamless system integration.
Measuring accurately smallest quantities of liquids and gases. -
Sensor features
Space-saving installation – compact single-tube design. Fewer process measuring points – multivariable measurement (flow, density, temperature). Suitable for skids – lightweight sensor.
Nominal diameter: DN 1 to 6 (¹⁄₂₄ to ¹⁄₄"). Process pressure up to 400 bar (5800 psi). Medium temperature up to +200 °C (+392 °F). -
Transmitter features
High flexibility in system integration – wide range of communication interfaces. Fast commissioning – pre-configured devices. Automatic recovery of data for servicing.
Device as compact or remote version. Flexible outputs. Modbus RS485. -
Nominal diameter range
DN 1 to 6 (¹⁄₂₄ to ¹⁄₄")
-
Wetted materials
Measuring tube: 1.4539 (904L)
Connection: 1.4539 (904L); 1.4404 (316/316L) -
Measured variables
Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration
-
Max. measurement error
Mass flow (liquid): ±0.1 %
Volume flow (liquid): ±0.1 %
Mass flow (gas): ±0.5 %
Density (liquid): ±0.0005 g/cm3 -
Measuring range
0 to 1000 kg/h (0 to 37 lb/min)
-
Max. process pressure
PN 40, Class 300, 10K, 400 bar (5800 psi)
-
Medium temperature range
–50 to +200 °C (–58 to +392 °F)
-
Ambient temperature range
Standard: –20 to +60 °C (–4 to +140 °F)
Option: –40 to +60 °C (–40 to +140 °F) -
Sensor housing material
1.4301 (304), corrosion resistant
-
Transmitter housing material
Powder‐coated die‐cast aluminium
-
Degree of protection
IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure
-
Display/Operation
4‐line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible -
Outputs
4 modular outputs:
0‐20 mA (active)/4‐20 mA (active/passive)
Pulse/frequency/switch output (passive), phase‐shifted pulse
Relay -
Inputs
1 modular input: status
-
Digital communication
HART, Modbus RS485
-
Power supply
DC 16 to 62 V
AC 85 to 260 V (45 to 65 Hz)
AC 20 to 55 V (45 to 65 Hz) -
Hazardous area approvals
ATEX, IECEx, NEC/CEC, NEPSI
-
Other approvals and certificates
3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR, SIL
CRN
-
-
Tekniske oplysninger (TI)
Cubemass DCI Technical Information
-
Tekniske oplysninger (TI)
Engelsk version - 08/2015New version available in EnglishCoriolis flowmeter
The ultra-compact sensor for smallest quantities with seamless system
integrationEN DA 01/08/201523/03/201001/11/2009Sprog:
Engelsk
Version:
01/08/2015
Filstørrelse:
667.1 KB
Filnavn:
TI00099DEN_1315.pdf
-
-
-
Betjeningsvejledning (BA)
Cubemass DCI HART Operating Instructions
-
Betjeningsvejledning (BA)
Engelsk version - 11/2024New version available in EnglishCoriolis flowmeter
EN DA 15/11/202418/09/201523/03/201001/11/2009Sprog:
Engelsk
Version:
15/11/2024
Filstørrelse:
5.5 MB
Filnavn:
BA00139DDE_1424.pdf
-
-
-
Betjeningsvejledning (BA)
Cubemass DCI MODBUS RS485 Operating Instructions
-
Betjeningsvejledning (BA)
Engelsk version - 11/2024New version available in EnglishCoriolis flowmeter
EN DA 15/11/202418/09/201523/03/201001/11/2009Sprog:
Engelsk
Version:
15/11/2024
Filstørrelse:
6.3 MB
Filnavn:
BA00141DEN_1424.pdf
-
-
-
Enhedsparameter (GP)
Cubemass DCI MODBUS RS485 Description of Device Functions
-
Enhedsparameter (GP)
Engelsk version - 09/2015New version available in EnglishCoriolis flowmeter
EN DA 18/09/201501/11/2009Sprog:
Engelsk
Version:
18/09/2015
Filstørrelse:
1.1 MB
Filnavn:
GP00004DEN_1315.pdf
-
-
-
Enhedsparameter (GP)
Cubemass DCI HART Description of Device Functions
-
Enhedsparameter (GP)
Engelsk version - 09/2015New version available in EnglishCoriolis flowmeter
EN DA 18/09/201501/11/2009Sprog:
Engelsk
Version:
18/09/2015
Filstørrelse:
1 MB
Filnavn:
GP00002DEN_1315.pdf
-
-
-
Kort anvisning (KA)
Cubemass DCI Brief Operating Instructions
-
Kort anvisning (KA)
Engelsk version - 11/2009New version available in EnglishCoriolis mass flow measuring system
EN DA 01/11/2009Sprog:
Engelsk
Version:
01/11/2009
Filstørrelse:
592.7 KB
Filnavn:
KA045DEN_1109.pdf
-
-
-
Installationsanvisninger (EA)
EA Replacing cover and O-ring
-
Installationsanvisninger (EA)
Engelsk version - 10/2024New version available in EnglishProline 10, 23, 50, 51, 53, 55, 400, 800, 40, 80, 83, 84, 8ME, 8FF, 8FE
,8CM, 90, 91, 92, 93, 65, 72, 73EN DA 15/10/202401/10/201828/06/2012Sprog:
Engelsk
Version:
15/10/2024
Filstørrelse:
797.3 KB
Filnavn:
EA00098DA2_1624-00.pdf
-
-
-
Installationsanvisninger (EA)
Replacing interface parts Installation Instructions
-
Installationsanvisninger (EA)
Engelsk version - 04/2019New version available in EnglishPromass 40, 80, 83, 84, Cubemass 8CN, CNGmass 8DF
EN DA 01/04/201917/11/2011Sprog:
Engelsk
Version:
01/04/2019
Filstørrelse:
787.5 KB
Filnavn:
EA00036DA2_1519.pdf
-
-
-
Installationsanvisninger (EA)
Replacing Power supply and display Installation Instructions
-
Installationsanvisninger (EA)
Engelsk version - 11/2018New version available in EnglishPromag 50, 51, 53, 55, Promass 40, 80, 83, 84, 8ME, Cubemass DCI 8CN,
CNGmass DCI 8DF, Prosonic Flow 90, 93, t-mass 65EN DA 15/11/201818/11/2011Sprog:
Engelsk
Version:
15/11/2018
Filstørrelse:
455.1 KB
Filnavn:
EA00063DA2_1518.pdf
-
-
-
Installationsanvisninger (EA)
Replacing connecting cable Installation Instructions
-
Installationsanvisninger (EA)
Engelsk version - 10/2018New version available in EnglishPromass 60, 63, 64, 80, 83, 84
EN DA 01/10/201801/12/2009Sprog:
Engelsk
Version:
01/10/2018
Filstørrelse:
293.1 KB
Filnavn:
EA00081DA2_1218.pdf
-
Vælg blandt de foreslåede muligheder
-
-- selected coding-- selected label99.999,00<%label%>
-
Leder du efter flere indstillinger? Anvend den individuelle konfigurator for at fortsætte.
-
-- selected coding-- selected label99.999,00<%feature%>
-
<%label%>99.999,00
-
Leder du efter flere indstillinger? Anvend den individuelle konfigurator for at fortsætte.
-
Process Connection
-
<%label%>99.999,00
-
<%label%>99.999,00
-
-
<%feature%><%coding%><%label%>
- CAD-tegninger CAD-tegninger
- CAD-tegninger
-
Pris pr. enhed
-
<%range%><%price%>
-
- Valgfrie tilføjelser
Individuel konfiguration
Ofte købt sammen
Tilbehør
Relaterede produkter