The compact Deltapilot FMB50 transmitter with the condensate resistant Contite measuring cell is typically used in the process and hygienic applications. It is made for level measurement in liquid and paste-like media in open or closed containers and unaffected by possible foam formation. For use in SIL2 safety systems.
For level and/or pressure measurement.
Process connections: Thread, flanges and flush-mounted hygienic connections
Process temperature: –10 to +100°C (14 to 212°F) (+135°C (275°F) for 30 minutes maximum)
Measuring range: 0.1 to 10bar (1.5 to 150psi)
Accuracy: ±0.2%, ±0.1% (option)
International explosion protection certificates, overfill prevention WHG, SIL, hygienic certificates
Fordele
Hermetically sealed Contite measuring cell with condensate-resistance, high reference accuracy: ±0.2%, optionally ±0.1% and minimum temperature effects
Modular concept for easy replacement of display or electronics
Seamless and independent system integration (HART/PA/FF)
Easy menu-guided commissioning via local display, 4 to 20mA with HART, PROFIBUS PA, FOUNDATION Fieldbus
International usage thanks to a wide range of approvals
Videoer
IO-Link-kommunikation
IO-Link-kommunikation hjælper med at digitalisere dit anlæg
Protolaunch anvender flowmålere og niveausensorer fra Endress+Hauser på et testanlæg for raketfremdrift i Buckinghamshire for at demonstrere fremdriftssystemernes og komponenternes ydeevne.
Torishima udvikler og leverer store kølevandssystemer til kunder i Mellemøsten og sætter sin lid til Endress+Hausers måleudstyr på grund af produkternes kvalitet og ydeevne.
Messer producerer brint i en dampreformer. Anlægget har et stort antal beskyttelses- og sikkerhedsanordninger, hvor trykværdier spiller en vigtig rolle.
Compact pressure transmitter for hydrostatic level measurement with flush mounted metallic Contite measuring cell: Hermetically sealed, condensate-resistant, climatic-proofed and with lowest temperature influences
Supply voltage
4...20 mA HART 10,5...45 VDC (Non Ex): Ex ia: 10,5...30 VDC PROFIBUS PA: 9...32 VDC (Non Ex) FOUNDATION Fieldbus: 9...32 VDC (Non Ex)
Tri-Clamp DIN11851 DIN11864-1 NEUMO Varivent N SMS DRD
Max. measurement distance
100m (328ft) H2O
Communication
4...20 mA HART PROFIBUS PA FOUNDATION Fieldbus IO-Link
Certificates / Approvals
ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI
Safety approvals
Overfill protection WHG SIL
Design approvals
EN10204-3.1 NACE MR0103
Hygienic approvals
3A, EHEDG CoC ASME-BPE
Marine approval
GL/ ABS/ LR/ BV/ DNV
Drinking water approvals
KTW/ NSF/ ACS
Options
Separate housing Initial device settings Overvoltage protection
Application limits
If pressurized, usage of two pressure transmitters to measure the differential pressure (electronic dP) Observe ratio head pressure : hydrostatic pressure
Cerabar M / Deltabar M / Deltapilot M, Operating Instructions
FOUNDATION Fieldbus
Betjeningsvejledning (BA)
Engelsk version - 08/2024
New version available in English
Cerabar M PMC51, PMP51, PMP55 Pressure transmitter Deltabar M PMD55 Differential pressure transmitter Deltapilot M FMB50 Hyd rostatic pressure transmitter
Active barrier, 1 channel for 4 to 20 mA, HART® transparent with 24 to 230 V AC/DC as well as active/passive input and output, optionally with SIL and Ex
Active barrier, 1 channel for 4 to 20 mA, HART® transparent with 24 to 230 V AC/DC as well as active/passive input and output, optionally with SIL and Ex
Active barrier, 1 channel for 4 to 20 mA, HART® transparent with 24 to 230 V AC/DC as well as active/passive input and output, optionally with SIL and Ex
Vi anvender cookies for at forbedre din browseroplevelse, indsamle statistiske oplysninger med henblik på optimering af webstedets funktionalitet og levere skræddersyede annoncer eller indholdselementer.