Oversigt over specifikationer
-
Measuring range
2µS/cm to 2000 mS/cm
-
Process temperature
PEEK: max. 125°C (max. 260 °F)
PFA: max. 110°C (max. 230 °F) -
Process pressure
PEEK: max. 21 bar (max. 304.5 psi)
PFA: max. 17 bar (max. 246.5 psi)
Anvendelsesområde
Indumax CLS50D is a digital inductive conductivity sensor for standard, hazardous and high-temperature applications. Benefit from high chemical resistance and long durability thanks to robust materials (PFA, PEEK). Moreover, it is insensitive to soiling and performs reliable and repeatable even in harsh and aggressive media. Thanks to Memosens, CLS50D combines maximum process and data integrity with simple operation. It resists corrosion and moisture and facilitates predictive maintenance.
Indumax CLS50D measures toroidal conductivity in:
Chemicals:
- Concentration measurement of acids and bases
- Quality monitoring of chemical products in tanks and pipesFood & Beverages:
- Phase separation of product/product mixtures in pipe systemsLife Sciences:
- Phase separation of product/product mixtures in pipe systemsWastewater industry:
- Inlet monitoring
With its international explosion protection approvals, such as ATEX, FM, CSA, NEPSI, it is suitable for hazardous areas.
Fordele
High durability and chemical resistance even under harsh conditions
Dirt-repellent materials and large sensor opening avoid soiling
Wide temperature range and highly resistant materials make the sensor suitable for virtual any application
Reliable values thanks to active connection monitoring
Easy wiring over long distances without impact on the measurement accuracy
-
Logging of sensor-specific data for easy traceability
-
Approved for hazardous area use
Videoer
-
Standardprodukter
- Pålidelige og robuste med lav vedligeholdelse
Teknisk ydeevne
Enkelhed
-
Specialiserede produkter
- Designet til krævende applikationer
Teknisk ydeevne
Enkelhed
Variabel
FLEX valg | Teknisk ydeevne | Enkelhed |
---|---|---|
Fundamental Få dækket dine basale målebehov |
Teknisk ydeevne
|
Enkelhed
|
Lean Administrer nemt dine kerneprocesser |
Teknisk ydeevne
|
Enkelhed
|
Extended Optimer dine processer med innovative teknologier |
Teknisk ydeevne
|
Enkelhed
|
Xpert Til de mest udfordrende applikationer |
Teknisk ydeevne
|
Enkelhed
Variabel |
-
-
Ex-sikkerhedsanvisning (XA)
Indumax CLS50D, CLS50
Engelsk version - 03/2022
FM IS/NI Cl.I Div. 1/2 GP A, B, C and D Safety instructions for electrical apparatus in explosion-hazardous areas
Sprog:
Engelsk
Version:
22/03/2022
Filstørrelse:
429.3 KB
Filnavn:
XA02843CEN_0122-00.pdf
-
-
-
Tekniske oplysninger (TI)
TI Indumax CLS50D/CLS50
Engelsk version - 08/2023
Inductive conductivity sensor for standard, Ex and high-temperature applications
EN DA 09/08/202308/07/202227/01/202231/10/201831/01/2015Sprog:
Engelsk
Version:
09/08/2023
Filstørrelse:
943.2 KB
Filnavn:
TI00182CEN_2023-00.pdf
-
-
-
Tekniske oplysninger (TI)
TI Indumax CLS50D/CLS50
Inductive conductivity sensor for standard, Ex and high-temperature
applicationsEN DA 09/08/202308/07/202227/01/202231/10/201831/01/2015Sprog:
Engelsk
Version:
09/08/2023
Filstørrelse:
943.2 KB
Filnavn:
TI00182CEN_2023-00.pdf
-
-
-
Betjeningsvejledning (BA)
BA Indumax CLS50D/CLS50
Induktiv konduktivitetssensor til standardanvendelse, anvendelse i
farlige område og ved høje temperaturerEN DA 09/08/202321/02/202227/01/202031/10/201831/08/2017Sprog:
Dansk
Version:
09/08/2023
Filstørrelse:
801.3 KB
Filnavn:
BA00182CDA_2323-00.pdf
-
-
-
Ex-sikkerhedsanvisning (XA)
XA Indumax CLS50D
Inductive conductivity sensor for standard, Ex and high-temperature
applications
JPN Ex ia IIC T4 GaEN DA 23/10/202327/08/2021Sprog:
Engelsk
Version:
23/10/2023
Filstørrelse:
425.6 KB
Filnavn:
XA02646CEN_0223-00.pdf
-
-
-
Ex-sikkerhedsanvisning (XA)
Indumax CLS50D, CLS50
FM IS/NI Cl.I Div. 1/2 GP A, B, C and D
Safety instructions for electrical apparatus in explosion-hazardous
areasSprog:
Engelsk
Version:
22/03/2022
Filstørrelse:
429.3 KB
Filnavn:
XA02843CEN_0122-00.pdf
-
-
-
Ex-sikkerhedsanvisning (XA)
XA Indumax CLS50D, CLS50
Inductive conductivity sensor for standard, Ex and high-temperature
applications
NEPSI Ex ia IIC T4/T6 GaEN DA 31/08/202308/03/202201/05/2009Sprog:
Engelsk
Version:
31/08/2023
Filstørrelse:
529.2 KB
Filnavn:
XA00441CEN_1423-00.pdf
-
-
-
Ex-sikkerhedsanvisning (XA)
CLS50D, CLS50, CLS54, CLS15D, CLS16D, CLS21D, CLS82D
Supplement to: BA00182C, BA01591C, BA01147C, BA01326C
Safety instructions for electrical apparatus in explosion-hazardous
areas
UK II 1G Ex ia IIC T3/T4/T6 GaEN DA 31/01/202220/10/2021Sprog:
Engelsk
Version:
31/01/2022
Filstørrelse:
459.6 KB
Filnavn:
XA02702CEN_0222-00.pdf
-
-
-
Ex-sikkerhedsanvisning (XA)
XA Indumax CLS50D
Inductive conductivity sensor for standard, Ex and high-temperature
applications
KOR Ex ia IIC T4/T6 GaEN DA 25/07/2024Sprog:
Engelsk
Version:
25/07/2024
Filstørrelse:
424.6 KB
Filnavn:
XA03302CEN_0124-00.pdf
-
-
-
Ex-sikkerhedsanvisning (XA)
XA Indumax CLS50D, CLS50
Inductive conductivity sensor for standard, Ex and high-temperature
applications
INMETRO Ex ia IIC T4/T6 GaEN DA 25/07/2024Sprog:
Engelsk
Version:
25/07/2024
Filstørrelse:
442.8 KB
Filnavn:
XA03306CEN_0124-00.pdf
-
-
-
Ex-sikkerhedsanvisning (XA)
XA Indumax CLS50D, CLS50
Induktiv konduktivitetssensor til standardanvendelse, anvendelse i
farlige område og ved høje temperaturer
ATEX / NEPSI Ex ic IIC T3 T4/T6 GcEN DA 20/09/202303/01/202307/03/2022Sprog:
Dansk
Version:
20/09/2023
Filstørrelse:
542.8 KB
Filnavn:
XA02837CDA_0323-00.pdf
-
-
-
Ex-sikkerhedsanvisning (XA)
Indumax CLS50D, CLS50, CLS54
CSA IS/NI Cl.I Div. 1/2 GP A, B, C and D
Safety instructions for electrical apparatus in explosion-hazardous
areasEN DA 24/03/2022Sprog:
Engelsk
Version:
24/03/2022
Filstørrelse:
438.4 KB
Filnavn:
XA02836CEN_0122-00.pdf
-
-
-
Ex-sikkerhedsanvisning (XA)
Indumax CLS50D, CLS50
ATEX II 1G Ex ia IIC T4/T6 Ga
IECEx ia IIC T4/T6 Ga (kun CLS50D)
Sikkerhedsanvisninger for elektrisk udstyr i områder med eksplosionsfareEN DA 07/03/202201/01/200701/09/200301/02/2000Sprog:
Dansk
Version:
07/03/2022
Filstørrelse:
445.3 KB
Filnavn:
XA00182CDA_1322-00.pdf
-
-
-
Ex-sikkerhedsanvisning (XA)
CLS15D, CLS16D, CLS21D, CLS50D, CLS50, CLS54, CLS82D
Safety instructions for electrical equipment in explosion-hazardous
areas
EAC Ex, 0Ex ia IIC T6/T4 Ga X
Supplement to:
BA01147C,BA00182C, BA01591C, BA01326CEN DA 01/03/202231/03/2021Sprog:
Engelsk
Version:
01/03/2022
Filstørrelse:
507 KB
Filnavn:
XA02375CEN_0222-00.pdf
-
-
-
Specialdokumentation (SD)
Special documentation Liquiline CM14 conductivity kit 3
For conductivitymeasurement in wastewater
EN DA 16/07/2012Sprog:
Engelsk
Version:
16/07/2012
Filstørrelse:
305.1 KB
Filnavn:
SD168_CM14_A5_71154961.pdf
-
-
-
Specialdokumentation (SD)
Special Documentation CLS50D, CLS54D
Installation advice for Indumax CLS50D and CLS54D
EN DA 10/10/201305/06/2013Sprog:
Engelsk
Version:
10/10/2013
Filstørrelse:
169.4 KB
Filnavn:
SD01211CEN_0213.pdf
-
-
-
Aktivitetsfelter (FA)
Kompetenz in der Flüssigkeitsanalyse
Vom Sensor bis zur schlüsselfertigen Komplettlösung
Sprog:
Tysk
Version:
21/09/2022
Filstørrelse:
1.3 MB
Filnavn:
FA01018CDE_0422_Analyse_Portfolio_lowres.pdf
-
-
-
Aktivitetsfelter (FA)
Sensors, transmitters, compact devices and assemblies
Experts in Liquid Analysis
Sprog:
Engelsk
Version:
24/09/2024
Filstørrelse:
4.2 MB
Filnavn:
FA00007CEN_Analyse_21.24_LowRes.pdf
-
-
-
Aktivitetsfelter (FA)
Sıvı analizinde uzmanlık
Sensörlerden komple anahtar teslim çözümlere
Sprog:
Tyrkisk
Version:
23/11/2023
Filstørrelse:
7.2 MB
Filnavn:
FA01088C56TR01.23.pdf
-
-
-
Aktivitetsfelter (FA)
Sensoren, Messumformer, Kompaktgeräte and Armaturen
Kompetenz in der Flüssigkeitsanalyse
Sprog:
Tysk
Version:
24/09/2024
Filstørrelse:
4.1 MB
Filnavn:
FA00007CDE_Analyse_21.24_LowRes.pdf
-
-
-
Aktivitetsfelter (FA)
Jistota v analýze kapalin
Od senzorů po kompletní dodávku na klíč
Sprog:
Tjekkisk
Version:
12/01/2017
Filstørrelse:
740.3 KB
Filnavn:
Analyza_FA01018Ccs_0216.pdf
-
-
-
Aktivitetsfelter (FA)
Expertise in liquid analysis
From sensors to complete turnkey solutions
Sprog:
Engelsk
Version:
21/09/2022
Filstørrelse:
1.2 MB
Filnavn:
FA01018CEN_0422_Analysis_Portfolio_lowres.pdf
-