- F
- L
- E
- X
Proline Promag 55S for applications with high solids content and high abrasion
Proline Promag 55S for applications with high solids content and high abrasion
Oversigt over specifikationer
-
Max. measurement error
Volume flow: ±0.5 % o.r.± 1 mm/s (0.04 in/s)
Option: ±0.2 % o.r. ± 2 mm/s (0.08 in/s) -
Measuring range
0.06 dm3/min to 600 m3/h (0.015 gal/min to 2650 gal/min)
-
Medium temperature range
0 to +60 °C (+32 to +140 °F), 0 to +80 °C (+32 to +176 °F), –20 to +50 °C (–4 to +122 °F), –20 to +180 °C (–4 to +356 °F), –20 to +150 °C (–4 to +266 °F)
-
Max. process pressure
PN 40, Cl. 300, JIS 20 K
-
Wetted materials
Liner: Polyurethane, Hard rubber, PFA, PTFE, Natural rubber
Electrodes: 1.4435/304L, Alloy C-22, Tantalum, Platinum, Duplex 1.4465, Tungsten carbide, Titanum
Anvendelsesområde
Promag S is the specialist for inhomogeneous, abrasive and corrosive fluids. The robust sensor design, featuring industry-optimized liners, enables its use in most challenging surroundings and metering jobs such as sewage treatment, pulp and paper production or in the primaries and metals industry. Due to its high-performance transmitter, Promag 55S not only measures flow reliably, but also calculates solids content at low maintenance requirements.
The bidirectional measuring principle is virtually independent of pressure, density, temperature and viscosity
Ideal for the most demanding applications with high solids content and high abrasion.
Device properties
Intensified coil system
Large range of liners
Solids content up to 80 % by weight
4-line backlit display with touch control
Two switch outputs
HART, PROFIBUS PA/DP, FOUNDATION Fieldbus
Fordele
Superb signal stability due to unique signal processing
Maximum safety – industry-optimized measuring electrodes and linings
Energy-saving flow measurement – no pressure loss due to cross-section constriction
Maintenance-free – no moving parts
Highest performance – with integrated solids measurement for demanding fluids
Highest safety – integrated electrode cleaning
Automatic recovery of data for servicing
Videoer
-
The Electromagnetic Flow Measuring Principle
Forgænger
-
Standardprodukter
- Pålidelige og robuste med lav vedligeholdelse
Teknisk ydeevne
Enkelhed
-
Specialiserede produkter
- Designet til krævende applikationer
Teknisk ydeevne
Enkelhed
Variabel
| FLEX valg | Teknisk ydeevne | Enkelhed |
|---|---|---|
Fundamental Få dækket dine basale målebehov |
Teknisk ydeevne
|
Enkelhed
|
Lean Administrer nemt dine kerneprocesser |
Teknisk ydeevne
|
Enkelhed
|
Extended Optimer dine processer med innovative teknologier |
Teknisk ydeevne
|
Enkelhed
|
Xpert Til de mest udfordrende applikationer |
Teknisk ydeevne
|
Enkelhed
Variabel |
-
Measuring principle
Electromagnetic
-
Product headline
The flowmeter with outstanding abrasion resistance and integrated solids content diagnostics.
Superb signal stability due to unique signal processing.
Ideal for the most demanding applications with high solids content and high abrasion. -
Sensor features
Maximum safety – industry-optimized measuring electrodes and linings. Energy‐saving flow measurement – no pressure loss due to cross section constriction. Maintenance‐free – no moving parts.
Intensified coil system. Large range of liners. Solids content up to 80 % by weight. -
Transmitter features
Highest performance – with integrated solids measurement for demanding fluids. Highest safety – integrated electrode cleaning. Automatic recovery of data for servicing.
4-line backlit display with touch control. Two switch outputs. HART, PROFIBUS PA/DP, FOUNDATION Fieldbus. -
Nominal diameter range
DN 15...600
1/2"...24" -
Wetted materials
Liner: Polyurethane, Hard rubber, PFA, PTFE, Natural rubber
Electrodes: 1.4435/304L, Alloy C-22, Tantalum, Platinum, Duplex 1.4465, Tungsten carbide, Titanum -
Measured variables
Volume flow, electrical conductivity, mass flow
-
Max. measurement error
Volume flow: ±0.5 % o.r.± 1 mm/s (0.04 in/s)
Option: ±0.2 % o.r. ± 2 mm/s (0.08 in/s) -
Measuring range
0.06 dm3/min to 600 m3/h (0.015 gal/min to 2650 gal/min)
-
Max. process pressure
PN 40, Cl. 300, JIS 20 K
-
Medium temperature range
0 to +60 °C (+32 to +140 °F), 0 to +80 °C (+32 to +176 °F), –20 to +50 °C (–4 to +122 °F), –20 to +180 °C (–4 to +356 °F), –20 to +150 °C (–4 to +266 °F)
-
Ambient temperature range
–40 to +60 °C (–40 to +140 °F)
-
Sensor housing material
Aluminum coated AlSi10Mg, carbon steel with protective varnish
-
Transmitter housing material
Powder-coated die-cast aluminum
-
Degree of protection
Standard: IP 67 (Type 4X enclosure) for transmitter and sensor
Optional: IP 68 (Type 6P enclosure) for remote version of Promag S sensor -
Display/Operation
Liquid-crystal display: illuminated, four lines with 16 characters per line
Onsite operation with three optical sensor keys -
Outputs
4...20mA
(active/passive) Pulse-/ Frequency output (active/passive)
Two status outputs -
Inputs
Status
Current input -
Digital communication
HART, PROFIBUS DP/PA, FOUNDATION Fieldbus
-
Power supply
AC 20 to 260 V
DC 20 to 64 V -
Hazardous area approvals
ATEX, FM, CSA, UK Ex
-
Product safety
CE, C-tick, EAC marking
-
Pressure approvals and certificates
CRN, PED
-
Material certificates
3.1 material
-
Hygienic approvals and certificates
Drinking water approval:ACS, KTW-BWGL, NSF 61, WRAS BS 6920
-
-
Tekniske oplysninger (TI)
Proline Promag 55S Technical Information
-
Tekniske oplysninger (TI)
Engelsk version - 04/2021New version available in EnglishElectromagnetic Flow Measuring
Flow rate measurement of liquids with solids content or inhomogeneous
liquidsEN DA 27/04/202127/11/201701/03/201116/10/200901/12/2007Sprog:
Engelsk
Version:
27/04/2021
Filstørrelse:
3.4 MB
Filnavn:
TI00071DEN_1521.pdf
-
-
-
Betjeningsvejledning (BA)
Proline Promag 55 PROFIBUS DP/PA Description of Device Functions
-
Betjeningsvejledning (BA)
Engelsk version - 02/2011New version available in EnglishDescription of the device functions (Options and inputs). Additional
documentation for Proline Promag 55 PROFIBUS DP/PA Operating
Instructions.EN DA 01/02/201114/09/201001/12/200701/09/2006Sprog:
Engelsk
Version:
01/02/2011
Filstørrelse:
1.1 MB
Filnavn:
BA00125DEN_1311.pdf
-
-
-
Betjeningsvejledning (BA)
Proline Promag 55
-
Betjeningsvejledning (BA)
Engelsk version - 10/2009New version available in EnglishDescription of the device functions (Options and inputs). Additional
documentation for Proline Promag 55 Operating Instructions.EN DA 19/10/200901/11/200701/09/2006Sprog:
Engelsk
Version:
19/10/2009
Filstørrelse:
1.5 MB
Filnavn:
BA120DEN_1009.pdf
-
-
-
Betjeningsvejledning (BA)
Proline Promag 55 FOUNDATION Fieldbus Description of Device Functions
-
Betjeningsvejledning (BA)
Engelsk version - 12/2009New version available in EnglishDescription of the device functions (Options and inputs). Additional
documentation for Proline Promag 55 FOUNDATION Fieldbus Operating
Instructions.EN DA 01/12/200901/09/2006Sprog:
Engelsk
Version:
01/12/2009
Filstørrelse:
1.4 MB
Filnavn:
BA127DEN_0709.pdf
-
-
-
Betjeningsvejledning (BA)
Proline Promag 55 PROFIBUS DP/PA Operating Instructions
-
Betjeningsvejledning (BA)
Engelsk version - 11/2017New version available in EnglishElectromagnetic Flow Measuring System for liquids with solids content or
inhomogeneous liquids. The description of the device functions are in a
separate documentation.EN DA 27/11/201701/03/201114/09/201019/10/200901/12/2007Sprog:
Engelsk
Version:
27/11/2017
Filstørrelse:
8.7 MB
Filnavn:
BA00124DEN_1417.pdf
-
-
-
Betjeningsvejledning (BA)
Proline Promag 55
-
Betjeningsvejledning (BA)
Engelsk version - 04/2021New version available in EnglishElectromagnetic Flow Measuring System for liquids with solids content or
inhomogeneous liquids. The description of the device functions are in a
separate documentation.EN DA 27/04/202113/11/201719/10/200901/11/200701/09/2006Sprog:
Engelsk
Version:
27/04/2021
Filstørrelse:
8 MB
Filnavn:
BA00119DEN_1421.pdf
-
-
-
Betjeningsvejledning (BA)
Proline Promag 55 FOUNDATION Fieldbus Operating Instructions
-
Betjeningsvejledning (BA)
Engelsk version - 11/2017New version available in EnglishElectromagnetic Flow Measuring System for liquids with solids content or
inhomogeneous liquids. The description of the device functions are in a
separate documentation.EN DA 27/11/201701/12/200901/09/2006Sprog:
Engelsk
Version:
27/11/2017
Filstørrelse:
5.6 MB
Filnavn:
BA00126DEN_1317.pdf
-
-
-
Kort anvisning (KA)
Proline Promag 55 Brief Operating Instructions
-
Kort anvisning (KA)
Engelsk version - 04/2021New version available in EnglishElectromagnetic Flow Measuring System
EN DA 27/04/202127/11/201728/09/201518/03/201101/03/2011Sprog:
Engelsk
Version:
27/04/2021
Filstørrelse:
2.3 MB
Filnavn:
KA00029DEN_1721.pdf
-
-
-
Installationsanvisninger (EA)
EA Replacing cover and O-ring
-
Installationsanvisninger (EA)
Engelsk version - 10/2024New version available in EnglishProline 10, 23, 50, 51, 53, 55, 400, 800, 40, 80, 83, 84, 8ME, 8FF, 8FE
,8CM, 90, 91, 92, 93, 65, 72, 73EN DA 15/10/202401/10/201828/06/2012Sprog:
Engelsk
Version:
15/10/2024
Filstørrelse:
797.3 KB
Filnavn:
EA00098DA2_1624-00.pdf
-
-
-
Installationsanvisninger (EA)
Replacing Power supply and display Installation Instructions
-
Installationsanvisninger (EA)
Engelsk version - 11/2018New version available in EnglishPromag 50, 51, 53, 55, Promass 40, 80, 83, 84, 8ME, Cubemass DCI 8CN,
CNGmass DCI 8DF, Prosonic Flow 90, 93, t-mass 65EN DA 15/11/201818/11/2011Sprog:
Engelsk
Version:
15/11/2018
Filstørrelse:
455.1 KB
Filnavn:
EA00063DA2_1518.pdf
-
Vælg blandt de foreslåede muligheder
-
-- selected coding-- selected label99.999,00<%label%>
-
Leder du efter flere indstillinger? Anvend den individuelle konfigurator for at fortsætte.
-
-- selected coding-- selected label99.999,00<%feature%>
-
<%label%>99.999,00
-
Leder du efter flere indstillinger? Anvend den individuelle konfigurator for at fortsætte.
-
Process Connection
-
<%label%>99.999,00
-
<%label%>99.999,00
-
-
<%feature%><%coding%><%label%>
- CAD-tegninger CAD-tegninger
- CAD-tegninger
-
Pris pr. enhed
-
<%range%><%price%>
-
- Valgfrie tilføjelser
Individuel konfiguration
Ofte købt sammen
Tilbehør
Relaterede produkter