Oversigt over specifikationer
-
Accuracy
Rod probe :+/- 2 mm (0.08 in)
Rope probe <= 15 m (49 ft): +/- 2 mm (0.08 in)
Rope probe > 15 m (49 ft): +/- 10 mm (0.39 in)
Coaxial probe: +/- 2 mm (0.08 in) -
Process temperature
-50...+200 °C
(-58...+392 °F) -
Process pressure / max. overpressure limit
Vacuum...40 bar
(Vacuum...580 psi) -
Max. measurement distance
Rod: 10 m (33 ft) Min DK>1.6
Rope: 25 m...30 m (82ft...98 ft) Min DK>1.6;
30m...45 m (98ft...148 ft) Min DK>1,9
Coaxial probe: 6 m (20 ft) Min DK>1.4 -
Main wetted parts
Rod probe:
316L, Alloy C, Ceramic
Rope probe:
316, 316L, Alloy C, Ceramic
Coaxial probe:
316L, Alloy C, Ceramic, PFA
Anvendelsesområde
Levelflex FMP51 for level measurement even under extreme process conditions like
high temperature and high pressure in the process industry. FMP51 offers maximum reliability even in case of moved surface and foam or when numerous tank baffles interfere with the measurement. Levelflex FMP51 is used for continuous level measurement of liquids, pastes and slurries but also for interface measurement. The measurement is not affected by changing media, temperature changes, gas blankets or vapors.
Version with rod, rope or coax probe.
Process connections: Threads or flange
Temperature: -50 to +200°C (-58 to +392°F)
Pressure: -1 to +40bar (-14.5 to +580psi)
Maximum measuring range: Rod 10m (33ft), rope 45m (148ft), coax 6m (20ft)
Accuracy: ±2mm (0.08")
International explosion protection certificates, overfill prevention WHG, SIL, marine approval, 5-point linearity protocol
Fordele
Reliable measurement even for changing product and process conditions
HistoROM data management concept for fast and easy commissioning, maintenance and diagnostics
Highest reliability due to new Multi-Echo Tracking evaluation
Hardware and software developed according to IEC 61508 up to SIL3
Heartbeat Technology for a cost-effective and safe plant operation during the entire life cycle
Seamless integration into control or asset management systems and intuitive, menu-guided operation concept (on-site or via the control system)
World's easiest proof test for SIL and WHG saves time and costs
Videoer

-
Standardprodukter
- Pålidelige og robuste med lav vedligeholdelse
Teknisk ydeevne
Enkelhed
-
Specialiserede produkter
- Designet til krævende applikationer
Teknisk ydeevne
Enkelhed
Variabel
FLEX valg | Teknisk ydeevne | Enkelhed |
---|---|---|
Fundamental Få dækket dine basale målebehov |
Teknisk ydeevne
|
Enkelhed
|
Lean Administrer nemt dine kerneprocesser |
Teknisk ydeevne
|
Enkelhed
|
Extended Optimer dine processer med innovative teknologier |
Teknisk ydeevne
|
Enkelhed
|
Xpert Til de mest udfordrende applikationer |
Teknisk ydeevne
|
Enkelhed
Variabel |
Forgænger
-
-
Teknisk information (TI)
Levelflex FMP51, FMP52, FMP54
Engelsk version - 04/2022
Guided wave radar
EN DA 22/02/202312/04/202231/07/202004/03/201912/04/2018Sprog:
Engelsk
Version:
12/04/2022
Filstørrelse:
4.8 MB
Filnavn:
TI01001FEN_2722-00.pdf
-
-
-
Beskyttelse Explosion
Product family: Levelflex
Engelsk version - 06/2019
Product root: FMP50-, FMP51-, FMP52-, FMP53-, FMP54-, FMP55-, FMP56-, FMP57- Region: Canada Approval agency: FM Category: I/2/A,B,C,D/T*, I/zone 0, I,II,III/1/A,B,C,D,E,F,G 070, 030~005/205 Protection: NI, IS, XP, Ex ia IIC T6...T1 Ga, 030~105 430 020 070 035
Sprog:
Engelsk
Version:
24/06/2019
Filstørrelse:
625.6 KB
Filnavn:
FM18CA0100XSupp03.pdf
-
-
-
Teknisk information (TI)
Levelflex FMP51 Modbus
Guided wave radar
EN DA 30/06/202228/02/2019Sprog:
Engelsk
Version:
30/06/2022
Filstørrelse:
3.4 MB
Filnavn:
TI01454FEN_0222-00.pdf
-
-
-
Teknisk information (TI)
Weld-in adapter, process adapter and flanges
Level and pressure measurement
EN DA 28/10/202119/06/202008/11/201917/08/201730/06/2016Sprog:
Engelsk
Version:
28/10/2021
Filstørrelse:
2.9 MB
Filnavn:
TI00426FEN_2321.pdf
-
-
-
Teknisk information (TI)
Levelflex FMP51, FMP52, FMP54
Guided wave radar
EN DA 22/02/202312/04/202231/07/202004/03/201912/04/2018Sprog:
Engelsk
Version:
22/02/2023
Filstørrelse:
4.9 MB
Filnavn:
TI01001FEN_2822-00.pdf
-
-
-
Betjeningsvejledining (BA)
Levelflex / Levelflex M Zentrierscheibe / Centering disk (PFA) Mounting Instructions
Accessory
EN DA 29/09/201727/02/201425/04/201208/02/201124/09/2010Sprog:
Engelsk
Version:
29/09/2017
Filstørrelse:
82.6 KB
Filnavn:
BA00378FA2_1717.pdf
-
-
-
Betjeningsvejledining (BA)
Levelflex FMP51, FMP52, FMP54 PROFIBUS PA
Guided wave radar
EN DA 21/02/202330/06/202212/04/201816/11/201715/12/2016Sprog:
Engelsk
Version:
21/02/2023
Filstørrelse:
4.7 MB
Filnavn:
BA01006FEN_2022-00.pdf
-
-
-
Betjeningsvejledining (BA)
Levelflex FMP51, FMP52, FMP54 FOUNDATION Fieldbus
Guided wave radar
EN DA 21/02/202330/06/202212/04/201816/11/201715/12/2016Sprog:
Engelsk
Version:
21/02/2023
Filstørrelse:
5.9 MB
Filnavn:
BA01052FEN_0822-00.pdf
-
-
-
Betjeningsvejledining (BA)
Accessory
Centering star PEEK
EN DA 27/02/201424/09/201003/12/200802/04/2008Sprog:
Engelsk
Version:
27/02/2014
Filstørrelse:
99.3 KB
Filnavn:
BA00377FA2_1414.pdf
-
-
-
Betjeningsvejledining (BA)
Levelflex FMP51 Modbus
Guided wave radar
EN DA 12/04/202204/03/2019Sprog:
Engelsk
Version:
12/04/2022
Filstørrelse:
4.5 MB
Filnavn:
BA01957FEN_0222-00.pdf
-
-
-
Betjeningsvejledining (BA)
Levelflex FMP51, FMP52, FMP54
Guidet niveauradar - Niveau- og skillelagsmåling i væsker - HART
EN DA 13/12/202230/06/202231/07/202012/04/201816/11/2017Sprog:
Dansk
Version:
14/12/2012
Filstørrelse:
5.8 MB
Filnavn:
BA01001FDA_1512.pdf
-
-
-
Instrument parameter(GP)
Levelflex FMP50, FMP51, FMP52, FMP53, FMP54, FMP55, FMP56, FMP57 PROFIBUS PA Description of Device Parameters
Guided wave radar
EN DA 30/10/201404/08/2011Sprog:
Engelsk
Version:
30/10/2014
Filstørrelse:
4.7 MB
Filnavn:
GP01001FEN_1314.pdf
-
-
-
Instrument parameter(GP)
Levelflex FMP5x Modbus Description of Device Parameters
Guided wave radar
EN DA 04/03/2019Sprog:
Engelsk
Version:
04/03/2019
Filstørrelse:
3 MB
Filnavn:
GP01140FEN_0119.pdf
-
-
-
Instrument parameter(GP)
Levelflex FMP5x HART Description of Device Parameters
Guided wave radar
EN DA 28/04/201630/10/201426/02/201429/07/201101/10/2010Sprog:
Engelsk
Version:
28/04/2016
Filstørrelse:
3.3 MB
Filnavn:
GP01000FEN_1616.pdf
-
-
-
Instrument parameter(GP)
Levelflex FMP50, FMP51, FMP52, FMP53, FMP54, FMP55, FMP56, FMP57 FOUNDATION Fieldbus Description of Device Parameters
Guided wave radar
EN DA 09/06/201527/04/2012Sprog:
Engelsk
Version:
09/06/2015
Filstørrelse:
3.5 MB
Filnavn:
GP01015FEN_0215.pdf
-
-
-
Kort instruktion (KA)
Levelflex FMP51, FMP52, FMP54 HART
Guidet bølgeradar
EN DA 30/06/202205/04/202212/04/201817/11/201712/02/2015Sprog:
Dansk
Version:
05/04/2022
Filstørrelse:
1.5 MB
Filnavn:
KA01077FDA_1922-00.pdf
-
-
-
Kort instruktion (KA)
Levelflex FMP51, FMP52, FMP54 FOUNDATION Fieldbus
Guidet bølgeradar
EN DA 30/06/202205/04/202212/04/201830/11/201717/11/2017Sprog:
Dansk
Version:
05/04/2022
Filstørrelse:
1.3 MB
Filnavn:
KA01107FDA_0722-00.pdf
-
-
-
Kort instruktion (KA)
Levelflex FMP51, FMP52, FMP54 PROFIBUS PA
Guidet bølgeradar
EN DA 30/06/202205/04/202212/04/201817/11/201712/02/2015Sprog:
Dansk
Version:
05/04/2022
Filstørrelse:
1.3 MB
Filnavn:
KA01079FDA_1722-00.pdf
-
-
-
Kort instruktion (KA)
Screw set for Micropilot II/M, Levelflex M, Prosonic M
Screw set for Micropilot II/M, Levelflex M, Prosonic M
EN DA 15/04/2021Sprog:
Engelsk
Version:
15/04/2021
Filstørrelse:
532.2 KB
Filnavn:
KA00512F00_A2.pdf
-
-
-
Kort instruktion (KA)
Levelflex FMP51 Modbus
Guidet bølgeradar
EN DA 30/06/202205/04/202204/03/2019Sprog:
Dansk
Version:
05/04/2022
Filstørrelse:
1.4 MB
Filnavn:
KA01421FDA_0222-00.pdf
-
-
-
Installationsvejledning (EA)
Replacing the display module Installation Instructions
Promag 200, Promass 200, Prosonic Flow 200, Prowirl 200, t-mass 150, Levelflex FMP5x, Micropilot FMR5x, Micropilot FMR6x, Remote dis play FHX50
EN DA 01/09/201701/02/201724/11/201528/11/201306/04/2012Sprog:
Engelsk
Version:
01/09/2017
Filstørrelse:
562.2 KB
Filnavn:
EA00102DA2_1817.pdf
-
-
-
Installationsvejledning (EA)
Set HF cable for compact and remte versions Installation Instruction
Levelflex
EN DA 17/07/202010/02/201519/07/2011Sprog:
Engelsk
Version:
17/07/2020
Filstørrelse:
1.8 MB
Filnavn:
EA00059FA2_0320.pdf
-
-
-
Installationsvejledning (EA)
Set housing security clamp Installation Instructions
Levelflex FMP5x, Micropilot FMR5x, Micropilot FMR6x Promag 200, Promass 200, Prosonic Flow 200, Prowirl 200,
EN DA 31/08/201707/10/201305/01/2012Sprog:
Engelsk
Version:
31/08/2017
Filstørrelse:
279.5 KB
Filnavn:
EA00038FA2_1717.pdf
-
-
-
Installationsvejledning (EA)
Main electronics module Installation Instructions
Levelflex FMP5x, Micropilot FMR5x, Micropilot FMR6x
EN -