Oversigt over specifikationer
-
Process temperature
-40 °C ... 150 °C
(-40 °F ... 302 °F) -
Process pressure / max. overpressure limit
Vacuum ... 40 bar
(Vacuum ... 580 psi) -
Min. density of medium
>0,7g/cm³
(>0,5g/cm³ optional)
Anvendelsesområde
Liquiphant FTL33 is a point level switch for liquids. The FTL33 is especially designed for food & beverage applications where hygienic requirements are requested. The Liquiphant is used for overfill protection or pump dry-run protection. The IO-Link capability allows easy parameter setting.
Compact:
- Smallest vibronic sensor in the market
Safe:
- Continuous self-monitoring
- Reliable switching independent of media properties
Easy:
- No calibration
- Plug & play
-IO-Link connectivity
Point level switch in compact hygienic design with stainless steel housing for the food industry.
Process connections: Threads, hygienic process connections, M24 process adapter
Temperature: -40 to +150°C (-40 to +302°F)
Pressure: -1 to +40bar (-14.5 to +580psi)
Surface roughness: 0.76µm or 1.5µm
Overfill protection and leakage detection WHG, hygienic certificates, final inspection report
Fordele
Designed for hygienic applications especially in the food industry - hygienic process connections and approvals available. IO-Link reduces costs and complexity due to easy configuration of the devices via engineering tools
CIP and SIP cleanability ensured - up to protection class IP69k
-
Designed according to highest requirements to quality and environmental sustainability, the self-monitoring Liquiphant offers safe switching also in case of power supply loss
-
Independent of changing media properties an accurate switching point is offered
-
A real plug & play sensor is offered without any need for adjustment even with changing media. Measurement is unaffected by conductivity, build-up, turbulence, flows or air bubbles
-
No calibration is required, no specific know-how or tools (e.g. software) necessary
-
Robust design made of stainless steel (316L) assures highest durability - no mechanically moved parts, free of maintenance
Videoer
Fundamental
-
Enkle produkter
- Nemme at vælge, installere og betjene
Teknisk ydeevne
Enkelhed
-
Standardprodukter
- Pålidelige og robuste med lav vedligeholdelse
Teknisk ydeevne
Enkelhed
-
Specialiserede produkter
- Designet til krævende applikationer
Teknisk ydeevne
Enkelhed
Variabel
FLEX valg | Teknisk ydeevne | Enkelhed |
---|---|---|
Fundamental Få dækket dine basale målebehov |
Teknisk ydeevne
|
Enkelhed
|
Lean Administrer nemt dine kerneprocesser |
Teknisk ydeevne
|
Enkelhed
|
Extended Optimer dine processer med innovative teknologier |
Teknisk ydeevne
|
Enkelhed
|
Xpert Til de mest udfordrende applikationer |
Teknisk ydeevne
|
Enkelhed
Variabel |
Forgænger
-
-
Betjeningsvejledning (BA)
Liquiphant FTL33
Engelsk version - 07/2022
Point level switch for liquids in the food industry
EN DA 12/07/202215/05/201530/09/201429/09/2014Sprog:
Engelsk
Version:
12/07/2022
Filstørrelse:
1.1 MB
Filnavn:
BA01286FEN_0322-00.pdf
-
-
-
Tekniske oplysninger (TI)
Liquiphant FTL33
Engelsk version - 07/2022
Vibronic
EN DA 12/07/202227/01/202130/05/201630/09/2014Sprog:
Engelsk
Version:
12/07/2022
Filstørrelse:
1.3 MB
Filnavn:
TI01148FEN_0522-00.pdf
-
-
-
Tekniske oplysninger (TI)
Liquiphant FTL33 IO- Link
Vibronic
EN DA 27/01/202103/12/2018Sprog:
Engelsk
Version:
27/01/2021
Filstørrelse:
1007.6 KB
Filnavn:
TI01434FEN_0221.pdf
-
-
-
Tekniske oplysninger (TI)
Liquiphant FTL33
Vibronic
EN DA 12/07/202227/01/202130/05/201630/09/2014Sprog:
Engelsk
Version:
12/07/2022
Filstørrelse:
1.3 MB
Filnavn:
TI01148FEN_0522-00.pdf
-
-
-
Tekniske oplysninger (TI)
TI Weld-in adapter, process adapter and flanges
Level, pressure and temperature measurement
EN DA 25/03/202415/09/202328/10/202130/07/202119/06/2020Sprog:
Engelsk
Version:
25/03/2024
Filstørrelse:
1.1 MB
Filnavn:
TI00426FEN_2524.pdf
-
-
-
Betjeningsvejledning (BA)
Liquiphant FTL33 IO-Link
Punktniveauafbryder til væske i fødevareindustrien
EN DA 12/10/202021/12/201803/12/2018Sprog:
Dansk
Version:
12/10/2020
Filstørrelse:
1.2 MB
Filnavn:
BA01934FDA_0320.pdf
-
-
-
Betjeningsvejledning (BA)
Liquiphant FTL33
Point level switch for liquids in the food industry
EN DA 12/07/202215/05/201530/09/201429/09/2014Sprog:
Engelsk
Version:
12/07/2022
Filstørrelse:
1.1 MB
Filnavn:
BA01286FEN_0322-00.pdf
-
-
-
Kort anvisning (KA)
Liquiphant FTL33
Punktniveauafbryder til væske i fødevareindustrien
EN DA 03/10/2022Sprog:
Dansk
Version:
03/10/2022
Filstørrelse:
344.2 KB
Filnavn:
KA01619FDA_0122-00.pdf
-
-
-
Kort anvisning (KA)
Liquiphant FTL33 IO-Link
Punktniveauafbryder til væske i fødevareindustrien
EN DA 03/10/2022Sprog:
Dansk
Version:
03/10/2022
Filstørrelse:
334.7 KB
Filnavn:
KA01620FDA_0122-00.pdf
-
-
-
Kort anvisning (KA)
Liquiphant FTL33, FTL20H, FTL5xH Operating Instructions
Weld-in adapter
EN DA 24/11/201407/02/2006Sprog:
Engelsk
Version:
24/11/2014
Filstørrelse:
144.8 KB
Filnavn:
KA00269FA6_1314.pdf
-
-
-
ZE (certifikat)
Herstellerbescheinigung/Declaration of Compliance Liquiphant FTL33
HE_00153_01.15
EN DA 02/11/2015Sprog:
Engelsk
Version:
02/11/2015
Filstørrelse:
874.8 KB
Filnavn:
ZE01025FA2_0115.pdf
-
-
-
ZE (certifikat)
Liquiphant FTL31, FTL33
Allgemeine bauaufsichtliche Zulassung /
Allgemeine Bauartzulassung Z-65.40-532 (DIBt) für Liquiphant
LeckageEN DA 22/07/201917/09/2014Sprog:
Tysk
Version:
22/07/2019
Filstørrelse:
1.5 MB
Filnavn:
ZE01011FDE_0219.pdf
-
-
-
ZE (certifikat)
Liquiphant FTL31, FTL33
Allgemeine bauaufsichtliche Zulassung /
Allgemeine Bauartzulassung Z-65.11-531 (DIBt) für LiquiphantEN DA 22/07/201917/09/2014Sprog:
Tysk
Version:
22/07/2019
Filstørrelse:
1.5 MB
Filnavn:
ZE01010FDE_0219.pdf
-
-
-
ZE (certifikat)
Certificate of Compliance Liquiphant FTL33
09/2014 (EHEDG)
Sprog:
Engelsk
Version:
28/04/2015
Filstørrelse:
959 KB
Filnavn:
ZE01017FEN_0115.pdf
-
-
-
Specialdokumentation (SD)
SD M12 socket
Accessories for devices with M12 plug
EN DA 30/06/202329/05/2020Sprog:
Engelsk
Version:
30/06/2023
Filstørrelse:
289.2 KB
Filnavn:
SD02586FEN_0223-00.pdf
-
-
-
Specialdokumentation (SD)
Application conditions for seals and plastics in the food sector Level measurement, pressure measurement Special Documentation
Application conditions for seals and plastics in the food sector
EN DA 23/07/2019Sprog:
Engelsk
Version:
23/07/2019
Filstørrelse:
97.6 KB
Filnavn:
SD02430FEN_0119.pdf
-
-
-
Specialdokumentation (SD)
SD Hygiene certificates
Level and pressure measuring devices
EN DA 27/09/202315/12/202129/01/202105/06/202018/12/2019Sprog:
Engelsk
Version:
27/09/2023
Filstørrelse:
552.2 KB
Filnavn:
SD02503FEN_0522-00.pdf
-
-
-
Specialdokumentation (SD)
Valve plug
Valve plug
EN DA 24/03/201604/07/2012Sprog:
Engelsk
Version:
24/03/2016
Filstørrelse:
63.1 KB
Filnavn:
SD00356FEN_0216.pdf
-
-
-
Specialdokumentation (SD)
Mounting hints for weld-in adapter Level and pressure measurement Special Documentation
Mounting hints for weld-in adapter
EN DA 28/04/2018Sprog:
Engelsk
Version:
28/04/2018
Filstørrelse:
294.2 KB
Filnavn:
SD01622PA3_0218.pdf
-
-
-
Specialdokumentation (SD)
Weldable pipe connection, flush mount for devices with M24 process connection
Accessories
EN DA 29/10/202109/12/2020Sprog:
Engelsk
Version:
29/10/2021
Filstørrelse:
346.3 KB
Filnavn:
SD02563FEN_0221-00.pdf
-
-
-
Specialdokumentation (SD)
Pipe connection clamp, flush mount for devices with M24 process connection
Accessories
EN DA 29/10/202109/12/2020Sprog:
Engelsk
Version:
29/10/2021
Filstørrelse:
428.5 KB
Filnavn:
SD02564FEN_0221-00.pdf
-
-
-
Aktivitetsfelter (FA)
Level measurement
Product overview for applications in liquids and bulk solids
Sprog:
Engelsk
Version:
14/10/2022
Filstørrelse:
10.5 MB
Filnavn:
FA00001F00EN2522.pdf
-