Specs at a glance
-
Max. measurement error
Volume flow (standard): ±0.5 % o.r. ± 1 mm/s (0.04 in/s)
-
Measuring range
9 dm³/min to 282 m³/h (2.5 gal/min to 1250 gal/min)
-
Medium temperature range
Liner material polyamide: 0 to +60°C (+32 to +140°F)
-
Max. process pressure
PN 16, Class 150, 10K
-
Wetted materials
Liner material polyamide: 0 to +60°C (+32 to +140°F)
Electrodes: 1.4435 (316L)
Field of application
The wafer flowmeter Promag D is designed for all basic water applications where space is at a minimum. With its straightforward hard- and software design, Promag D 10 simplifies every step in its life cycle from engineering to servicing at usual Endress+Hauser quality. Heartbeat Technology enables measurement reliability and compliant verification.
The bidirectional measuring principle is virtually independent of pressure, density, temperature and viscosity.
For basic water applications; optimized for limited space and plastic pipe installations
Device properties
Short installation length and low weight
Integrated ground disks made of stainless steel
International drinking water approvals
System integration with HART, Modbus RS485
Flexible operation with app and optional display
Benefits
-
Easy, fast centering of the sensor – innovative housing construction
-
Energy-saving flow measurement – no pressure loss due to cross section constriction
-
Maintenance-free – no moving parts
-
Optimum usability – operation with mobile devices and SmartBlue app or display with touch screen
-
Simple, time-saving commissioning – guided parameterization in advance and in the field
-
Integrated verification – Heartbeat Technology
Videos
Lean selection
-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections | Technical excellence | Simplicity |
---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
Predecessor
-
-
Technical Information (TI)
TI Proline Promag D 10
English version - 04/2024
Electromagnetic flowmeter
EN 26/04/202403/10/202201/08/2021Language:
English
Version:
26/04/2024
File size:
3.6 MB
File name:
TI01603DEN_0324-00.pdf
-
-
-
Operating Instruction (BA)
BA Proline Promag D 10
English version - 04/2024
Electromagnetic flowmeter HART
EN 26/04/202403/10/202201/08/2021Language:
English
Version:
26/04/2024
File size:
4.4 MB
File name:
BA02076DEN_0324-00.pdf
-
-
-
Technical Information (TI)
TI Proline Promag D 10
Electromagnetic flowmeter
EN 26/04/202403/10/202201/08/2021Language:
English
Version:
26/04/2024
File size:
3.6 MB
File name:
TI01603DEN_0324-00.pdf
-
-
-
Operating Instruction (BA)
BA Proline Promag D 10
Electromagnetic flowmeter
Modbus RS485EN 26/04/202403/10/202201/08/2021Language:
English
Version:
26/04/2024
File size:
3.7 MB
File name:
BA02077DEN_0324-00.pdf
-
-
-
Operating Instruction (BA)
BA Proline Promag D 10
Electromagnetic flowmeter
HARTEN 26/04/202403/10/202201/08/2021Language:
English
Version:
26/04/2024
File size:
4.4 MB
File name:
BA02076DEN_0324-00.pdf
-
-
-
Device Parameter (GP)
Proline Promag 10
Electromagnetic flowmeter
HARTEN 03/10/202201/07/2021Language:
English
Version:
03/10/2022
File size:
1.5 MB
File name:
GP01157DEN_0222-00.pdf
-
-
-
Device Parameter (GP)
Proline Promag 10
Electromagnetic flowmeter
Modbus RS485EN 03/10/202201/07/2021Language:
English
Version:
03/10/2022
File size:
1.6 MB
File name:
GP01158DEN_0222-00.pdf
-
-
-
Short Instruction (KA)
Flowmeter Proline 10
HART transmitter
with electromagnetic sensorEN 03/10/202201/07/2021Language:
English
Version:
03/10/2022
File size:
3.2 MB
File name:
KA01497DEN_0322-00.pdf
-
-
-
Short Instruction (KA)
Flowmeter Proline 10
Modbus RS485 transmitter
with electromagnetic sensorEN 03/10/202201/08/202101/07/2021Language:
English
Version:
03/10/2022
File size:
2.6 MB
File name:
KA01499DEN_0322-00.pdf
-
-
-
Short Instruction (KA)
Proline Promag D
Electromagnetic sensor
EN 01/08/202114/03/2017Language:
English
Version:
01/08/2021
File size:
1 MB
File name:
KA01264DEN_0221.pdf
-
-
-
Installation Instructions (EA)
Replacing the cable for the Sensor
Promag 10
EN 02/08/2021Language:
English
Version:
02/08/2021
File size:
867.5 KB
File name:
EA01352DA2_0121.pdf
-
-
-
Installation Instructions (EA)
EA Alteration of the display module
Proline 10
EN 15/03/202403/10/202201/04/2022Language:
English
Version:
15/03/2024
File size:
874.5 KB
File name:
EA01362DA2_0324-00.pdf
-
-
-
Installation Instructions (EA)
Replacing the Sensor
Promag 10
EN 03/10/202204/04/202220/08/2021Language:
English
Version:
03/10/2022
File size:
942.5 KB
File name:
EA01353DA2_0322-00.pdf
-
-
-
Installation Instructions (EA)
Replacing the transmitter, Ex db eb
Proline 10
EN 04/04/202220/08/2021Language:
English
Version:
04/04/2022
File size:
1.2 MB
File name:
EA01371DA2_0222-00.pdf
-
-
-
Installation Instructions (EA)
EA Replacing Small Parts
Proline 10, 400, 500, 500-digital, 800 Index B, 800 Index C, Cubemass
EN 01/01/202415/12/202101/05/202101/04/202101/06/2020Language:
English
Version:
01/01/2024
File size:
1.2 MB
File name:
EA01024DA2_1223-00.pdf
-
-
-
Installation Instructions (EA)
Replacing the electronics parts Exde
Proline 10
EN 15/03/202304/04/202201/05/2021Language:
English
Version:
15/03/2023
File size:
1.4 MB
File name:
EA01344DA2_0323-00.pdf
-
-
-
Installation Instructions (EA)
EA Replacing Small parts
Proline 10, 100, 400, 800 Index C, 500, 500-digital, CNG-, LNG-, LPGmass
EN 01/01/202401/05/202101/04/202131/07/202002/08/2019Language:
English
Version:
01/01/2024
File size:
518.1 KB
File name:
EA01119DA2_0923-00.pdf
-
-
-
Installation Instructions (EA)
Replacing the transmitter, non Ex/Zone 2/Div. 2/Ex db/Zone 1/Div. 1
Proline 10
EN 15/03/202303/10/202204/04/202220/08/2021Language:
English
Version:
15/03/2023
File size:
1.4 MB
File name:
EA01350DA2_0423-00.pdf
-
-
-
Installation Instructions (EA)
Replacing the electronic parts, non Ex/Zone 2/Div.2/Ex db/Zone1/Div.1
Proline 10
EN 03/10/202204/04/202201/05/2021Language:
English
Version:
03/10/2022
File size:
1.5 MB
File name:
EA01343DA2_0322-00.pdf
-
-
-
Installation Instructions (EA)
Replacing the backup coin cell for Real Time Clock
Proline 10
EN 03/10/202202/08/2021Language:
English
Version:
03/10/2022
File size:
715.2 KB
File name:
EA01347DA2_0222-00.pdf
-
-
-
Installation Instructions (EA)
Alteration with ISEM for HBT, Conductivity Measurement
Promag 10
EN 03/10/202201/04/2022Language:
English
Version:
03/10/2022
File size:
813.1 KB
File name:
EA01364DA2_0222-00.pdf
-
-
-
Installation Instructions (EA)
Activating application packages
Proline 10
EN 03/10/202201/04/2022Language:
English
Version:
03/10/2022
File size:
565.2 KB
File name:
EA01363DA2_0222-00.pdf
-
-
-
Installation Instructions (EA)
Replacing display module
Proline 10
EN 03/10/202204/04/202201/05/2021Language:
English
Version:
03/10/2022
File size:
749.3 KB
File name:
EA01345DA2_0322-00.pdf
-
-
-
Installation Instructions (EA)
Replacing the weather protection cover
Proline 10
EN 02/08/2021Language:
English
Version:
02/08/2021
File size:
521.4 KB
File name:
EA01351DA2_0121.pdf
-
-
-
Installation Instructions (EA)
Pipe mounting set
Promag, Promass, Prosonic Flow 500, Promag 10
EN 01/08/202101/02/2017Language:
English
Version:
01/08/2021
File size:
587.5 KB
File name:
EA01196DA2_0221.pdf
-
-
-
Installation Instructions (EA)
Replacing cover, O-ring, seal housing for transmitter wall mounting and seal housing for the sensor side
Promag 10, Promag, Promass, Prosonic Flow 500, 500-digital, t-mass
500-digitalEN 01/06/202101/05/202131/07/202002/08/201915/09/2018Language:
English
Version:
01/06/2021
File size:
1.2 MB
File name:
EA01162DA2_0621.pdf
-
-
-
Installation Instructions (EA)
Potting compound IP68
Promag 10, 400, 800 Remote Version, Promag 500, t-mass 500-digital
EN 01/05/202131/07/202001/03/201802/10/201701/08/2016Language:
English
Version:
01/05/2021
File size:
467 KB
File name:
EA01025DA2_0621.pdf
-
-
-
Installation Instructions (EA)
Replacing the interface seal
Proline 10
EN 28/11/202203/10/202204/04/202201/05/2021Language:
English
Version:
28/11/2022
File size:
1.3 MB
File name:
EA01342DA2_0422-00.pdf
-
-
-
Installation Instructions (EA)
Replacing cover, seal cover
Proline 10
EN 03/10/202201/05/2021Language:
English
Version:
03/10/2022
File size:
615.8 KB
File name:
EA01341DA2_0222-00.pdf
-
-
-
Installation Instructions (EA)
EA Replacing connection board
Proline 10, 500
EN 08/05/202414/11/202202/05/202201/05/202101/07/2019Language:
English
Version:
08/05/2024
File size:
687.4 KB
File name:
EA01149DA2_0724-00.pdf
-
-
-
Installation Instructions (EA)
EA Replacement of parts for the sensor connection housing, remote version
Proline 10, 400, 800 Index C, 500, 500-digital
EN 08/05/202401/12/202301/06/202304/04/202201/05/2021Language:
English
Version:
08/05/2024
File size:
875.7 KB
File name:
EA01095DA2_1224-00.pdf
-
-
File size:
File name:
-
-
Special Documentation (SD)
UKCA marking
Flow, density, concentration, viscosity
EN 04/11/202201/10/2021Language:
English
Version:
04/11/2022
File size:
357.4 KB
File name:
SD02752DEN_0222-00.pdf
-
-
-
Special Documentation (SD)
Display modules A400/A401/A402/A406/A407
Display with Bluetooth interface
EN 18/11/202220/08/202103/05/2021Language:
English
Version:
18/11/2022
File size:
1.4 MB
File name:
SD02655DEN_0322-00.pdf
-
-
-
Special Documentation (SD)
Technical Documentation
Device Viewer
Language:
English
Version:
01/04/2021
File size:
529.3 KB
File name:
SD02710DEN_0121.pdf
-
-
-
Special Documentation (SD)
SD DIN SPEC 91406
Automatic identification of physical objects
EN 17/05/202431/03/202401/12/202101/11/2021Language:
English
Version:
17/05/2024
File size:
649.4 KB
File name:
SD02825DEN_0424-00.pdf
-
-
-
Special Documentation (SD)
Proline Promag 10
Heartbeat Verification + Monitoring application package
Modbus RS485EN 01/10/202201/07/2021Language:
English
Version:
01/10/2022
File size:
2.6 MB
File name:
SD02715DEN_0222-00.pdf
-
-
-
Special Documentation (SD)
Proline Promag 10
Heartbeat Verification + Monitoring application package
HARTEN 01/10/202201/07/2021Language:
English
Version:
01/10/2022
File size:
2.6 MB
File name:
SD02714DEN_0222-00.pdf
-
-
-
Special Documentation (SD)
SD Use of Open Source
Software Licenses
EN 17/05/202427/04/202203/05/2021Language:
English
Version:
17/05/2024
File size:
524 KB
File name:
SD02658DEN_0324-00.pdf
-
-
-
Special Documentation (SD)
SD Promag
EAC Special Documentation
Language:
English
Version:
02/05/2024
File size:
817.3 KB
File name:
SD03239DEN_0124-00.pdf
-
-
-
Competence Brochure (CP)
Proline 10 (e-book, PC version)
Flow measurement uncompromisingly simple
Language:
English
Version:
21/02/2024
File size:
2.1 MB
File name:
CP01441DEN_0224_PC.pdf
-
-
-
Innovation (IN)
Proline 10
Misura di portata
semplice e senza compromessiLanguage:
Italian
Version:
13/07/2021
File size:
2.5 MB
File name:
IN01163DIT_0221.pdf
-