Oversigt over specifikationer
-
Max. measurement error
Volume flow (standard): ±0.5 % o.r.± 1 mm/s (0.04 in/s)
Volume flow (option): ±0.2 % o.r. ± 2 mm/s (0.08 in/s) -
Measuring range
4 dm³/min to 9600 m³/h (1 gal/min to 44 000 gal/min)
-
Medium temperature range
Liner material PFA: –20 to +150 °C (–4 to +302 °F)
Liner material PTFE: –40 to +130 °C (–40 to +266 °F) -
Max. process pressure
PN 40, Class 300, 20K
-
Wetted materials
Liner: PFA; PTFE
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum; Platinum; Titanium
Anvendelsesområde
Promag P is dedicated to chemical and process applications with corrosive liquids and high medium temperatures. With its straightforward hard- and software design, Promag P 10 simplifies every step in its life cycle from engineering to servicing at usual Endress+Hauser quality. Heartbeat Technology enables safe processes.
The bidirectional measuring principle is virtually independent of pressure, density, temperature and viscosity.
Dedicated to chemical and process applications with corrosive liquids.
Device properties
Nominal diameter: max. DN 600 (24")
All common Ex approvals
Liner made of PTFE or PFA
System integration with HART, Modbus RS485
Flexible operation with app and optional display
Fordele
Diverse applications – wide variety of wetted materials
Accurate measurement independent of disturbed flow profiles after obstacles in the pipe thanks to 0 x DN full-bore option
Energy-saving flow measurement – no pressure loss due to cross section constriction
Maintenance-free – no moving parts
Optimum usability – operation with mobile devices and SmartBlue app or display with touch screen
Simple, time-saving commissioning – guided parameterization in advance and in the field
Integrated verification – Heartbeat Technology
Videoer
-
Proline 10 – uncompromisingly simple
-
The world's first electromagnetic flowmeter for unrestricted measurements
-
The Electromagnetic Flow Measuring Principle
Forgænger
-
Standardprodukter
- Pålidelige og robuste med lav vedligeholdelse
Teknisk ydeevne
Enkelhed
-
Specialiserede produkter
- Designet til krævende applikationer
Teknisk ydeevne
Enkelhed
Variabel
| FLEX valg | Teknisk ydeevne | Enkelhed |
|---|---|---|
Fundamental Få dækket dine basale målebehov |
Teknisk ydeevne
|
Enkelhed
|
Lean Administrer nemt dine kerneprocesser |
Teknisk ydeevne
|
Enkelhed
|
Extended Optimer dine processer med innovative teknologier |
Teknisk ydeevne
|
Enkelhed
|
Xpert Til de mest udfordrende applikationer |
Teknisk ydeevne
|
Enkelhed
Variabel |
-
Measuring principle
Electromagnetic
-
Product headline
Flowmeter for basic process applications with easy-to-use operation concept.
Dedicated to chemical and process applications with corrosive liquids. -
Sensor features
Diverse applications – wide variety of wetted materials. Energy-saving flow measurement – no pressure loss due to cross section constriction. Maintenance-free – no moving parts.
Nominal diameter: max. DN 600 (24"). All common Ex approvals. Liner made of PTFE or PFA. -
Transmitter features
Optimum usability – operation with mobile devices and SmartBlue app or display with touch screen. Simple, time-saving commissioning – guided parameterization in advance and in the field. Integrated verification – Heartbeat Technology.
System integration with HART, Modbus RS485. Flexible operation with app and optional display. -
Nominal diameter range
DN 15 to 600 (½ to 24")
-
Wetted materials
Liner: PFA; PTFE
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum; Platinum; Titanium -
Measured variables
Volume flow, conductivity, mass flow
-
Max. measurement error
Volume flow (standard): ±0.5 % o.r.± 1 mm/s (0.04 in/s)
Volume flow (option): ±0.2 % o.r. ± 2 mm/s (0.08 in/s) -
Measuring range
4 dm³/min to 9600 m³/h (1 gal/min to 44 000 gal/min)
-
Max. process pressure
PN 40, Class 300, 20K
-
Medium temperature range
Liner material PFA: –20 to +150 °C (–4 to +302 °F)
Liner material PTFE: –40 to +130 °C (–40 to +266 °F) -
Ambient temperature range
Flange material carbon steel: –10 to +60 °C (+14 to +140 °F)
Flange material stainless steel: –40 to +60 °C (–40 to +140 °F) -
Sensor housing material
DN 15 to 300 (½ to 12""): AlSi10Mg, coated
DN 350 to 600 (14 to 24""): Carbon steel with protective varnish -
Transmitter housing material
AlSi10Mg, coated
-
Degree of protection
Standard: IP66/67, Type 4X enclosure
-
Display/Operation
2.4" LCD display with touch & auto rotate; Configuration and operation via Bluetooth technology possible
-
Outputs
4-20 mA HART (active/passive), Pulse/frequency/switch output
Modbus RS485, 4-20 mA -
Digital communication
HART, MODBUS RS485, IO-Link
-
Power supply
DC 24 V
AC 100 to 230 V
AC 100 to 230 V / DC 24 V (non-hazardous area) -
Hazardous area approvals
ATEX, IECEx, cCSAus, EAC, NEPSI, INMETRO, IND Ex, KC, JPN, UK Ex
-
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation) -
Pressure approvals and certificates
PED, CRN
-
Material certificates
3.1 material
-
Hygienic approvals and certificates
Driking water approvals: ACS; NSF61, WRAS
-
-
Tekniske oplysninger (TI)
Proline Promag P 10
-
Tekniske oplysninger (TI)
Engelsk version - 10/2022New version available in EnglishElectromagnetic flowmeter
EN DA 03/10/202201/07/2021Sprog:
Engelsk
Version:
03/10/2022
Filstørrelse:
3.8 MB
Filnavn:
TI01579DEN_0222-00.pdf
-
-
-
Betjeningsvejledning (BA)
Proline Promag P 10
-
Betjeningsvejledning (BA)
Engelsk version - 10/2022New version available in EnglishElectromagnetic flowmeter
HARTEN DA 03/10/202201/07/2021Sprog:
Engelsk
Version:
03/10/2022
Filstørrelse:
4.5 MB
Filnavn:
BA02069DEN_0222-00.pdf
-
-
-
Betjeningsvejledning (BA)
Proline Promag P 10
-
Betjeningsvejledning (BA)
Engelsk version - 10/2022New version available in EnglishElectromagnetic flowmeter
Modbus RS485EN DA 03/10/202201/07/2021Sprog:
Engelsk
Version:
03/10/2022
Filstørrelse:
3.9 MB
Filnavn:
BA02072DEN_0222-00.pdf
-
-
-
Enhedsparameter (GP)
Proline Promag 10
-
Enhedsparameter (GP)
Engelsk version - 10/2022New version available in EnglishElectromagnetic flowmeter
HARTEN DA 03/10/202201/07/2021Sprog:
Engelsk
Version:
03/10/2022
Filstørrelse:
1.5 MB
Filnavn:
GP01157DEN_0222-00.pdf
-
-
-
Enhedsparameter (GP)
Proline Promag 10
-
Enhedsparameter (GP)
Engelsk version - 10/2022New version available in EnglishElectromagnetic flowmeter
Modbus RS485EN DA 03/10/202201/07/2021Sprog:
Engelsk
Version:
03/10/2022
Filstørrelse:
1.6 MB
Filnavn:
GP01158DEN_0222-00.pdf
-
-
-
Kort anvisning (KA)
Flowmåler Proline 10
-
Kort anvisning (KA)
Dansk version - 10/2022New version available in EnglishHART-transmitter
med elektromagnetisk sensorEN DA 03/10/202201/07/2021Sprog:
Dansk
Version:
03/10/2022
Filstørrelse:
3.2 MB
Filnavn:
KA01497DDA_0322-00.pdf
-
-
-
Kort anvisning (KA)
Flowmåler Proline 10
-
Kort anvisning (KA)
Dansk version - 10/2022New version available in EnglishModbus RS485-transmitter
med elektromagnetisk sensorEN DA 03/10/202201/08/202101/07/2021Sprog:
Dansk
Version:
03/10/2022
Filstørrelse:
2.6 MB
Filnavn:
KA01499DDA_0322-00.pdf
-
-
-
Kort anvisning (KA)
Flowmåler Proline Promag P
-
Kort anvisning (KA)
Dansk version - 08/2022New version available in EnglishElektromagnetisk sensor
EN DA 02/03/202601/08/202201/07/202101/10/201701/02/2017Sprog:
Dansk
Version:
01/08/2022
Filstørrelse:
852.1 KB
Filnavn:
KA01290DDA_0422-00.pdf
-
-
-
Installationsanvisninger (EA)
EA Replacing the transmitter, non Ex/Zone 2/Div. 2/Ex db/Zone 1/Div. 1
-
Installationsanvisninger (EA)
Engelsk version - 12/2024New version available in EnglishProline 10
EN DA 06/12/202412/06/202415/03/202303/10/202204/04/2022Sprog:
Engelsk
Version:
06/12/2024
Filstørrelse:
1.4 MB
Filnavn:
EA01350DA2_0624-00.pdf
-
-
-
Installationsanvisninger (EA)
EA Replacing the transmitter, Ex db eb
-
Installationsanvisninger (EA)
Engelsk version - 12/2024New version available in EnglishProline 10
EN DA 06/12/202404/04/202220/08/2021Sprog:
Engelsk
Version:
06/12/2024
Filstørrelse:
1.3 MB
Filnavn:
EA01371DA2_0324-00.pdf
-
Vælg blandt de foreslåede muligheder
-
-- selected coding-- selected label99.999,00<%label%>
-
Leder du efter flere indstillinger? Anvend den individuelle konfigurator for at fortsætte.
-
-- selected coding-- selected label99.999,00<%feature%>
-
<%label%>99.999,00
-
Leder du efter flere indstillinger? Anvend den individuelle konfigurator for at fortsætte.
-
Process Connection
-
<%label%>99.999,00
-
<%label%>99.999,00
-
-
<%feature%><%coding%><%label%>
- CAD-tegninger CAD-tegninger
- CAD-tegninger
-
Pris pr. enhed
-
<%range%><%price%>
-
- Valgfrie tilføjelser
Individuel konfiguration
Ofte købt sammen
Tilbehør
Relaterede produkter