0.5 m3/h to 263000 m3/h (2.5gal/min to 1665 Mgal/d)
Medium temperature range
Liner material hard rubber: 0 to +80 °C (+32 to +176 °F) Liner material polyurethane: –20 to +50 °C (–4 to +122 °F) Liner material PTFE: –20 to +90 °C (–4 to +194°F)
Max. process pressure
PN 40, Class 300, 20K
Wetted materials
Liner material hard rubber: 0 to +80 °C (+32 to +176 °F) Liner material polyurethane: –20 to +50 °C (–4 to +122 °F) Liner material PTFE: –20 to +90 °C (–4 to +160 °F) Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022)
Thanks to its international approvals (e.g. for drinking water), Promag W serves a wide variety of applications. It is available as both compact or remote version. With its straightforward hard- and software design, Promag W 10 simplifies every step in its life cycle from engineering to servicing at usual Endress+Hauser quality. Heartbeat Technology enables measurement reliability and compliant verification.
The bidirectional measuring principle is virtually independent of pressure, density, temperature and viscosity.
Suitable for elementary measurement tasks such as raw water intake.
Device properties
International drinking water approvals
Degree of protection IP68 (Type 6P enclosure)
System integration with HART, Modbus RS485
Flexible operation with app and optional display
Fordele
Reliable measurement at constant accuracy with 0 x DN inlet run without pressure loss
Flexible engineering – sensor with fixed or lap-joint process connections
Application fitness – EN ISO 12944 corrosion protection for underground or underwater installation
Improved plant availability – sensor compliant with industry-specific requirements
Optimum usability – operation with mobile devices and SmartBlue app or display with touch screen
Simple, time-saving commissioning – guided parameterization in advance and in the field
Integrated verification – Heartbeat Technology
Videoer
Smart instrumentering via Heartbeat Technology
Ønsker du at give anlæggets ydeevne et boost og reducere omkostningerne? Vores udvalg inden for smart instrumentering med Heartbeat Technology tilbyder dybdegående instrumentindsigt, som sikrer omkostningseffektivitet og driftssikkerhed.
Read how Hölscher Wasserbau extracts, treats and reintroduces groundwater sustainably during the construction of the A-Nord high-voltage DC power line, while adhering to environmental regulations.
Torishima udvikler og leverer store kølevandssystemer til kunder i Mellemøsten og sætter sin lid til Endress+Hausers måleudstyr på grund af produkternes kvalitet og ydeevne.
Vialit-gruppen fremstiller forskellige produkter til vedligeholdelse af veje. Blanding af halvfabrikata kræver nøjagtig måling af flowhastighed og viskositet. Her leverer Promass I 500 resultater i særklasse.
Schluchseewerk AG ønskede at registrere og optimere effektiviteten af sine turbiner på pumpekraftværket i Wehr. Endress+Hauser tilbyder deres optimale løsning med deres clamp-on-ultralydsflowmåler.
Med Netilion Water kan Oberzents vandforsyningseksperter nu se alle relevante datapunkter for deres vandsystem på et cloud-baseret kontrolpanel, uden at de behøver besøge anlæggene.
Flowmeter for basic water and wastewater applications with easy-to-use operation concept. Reliable measurement at constant accuracy with 0 x DN inlet run without pressure loss. Suitable for elementary measurement tasks such as raw water intake.
Sensor features
Flexible engineering – sensor with fixed or lap-joint process connections. Application fitness – EN ISO 12944 corrosion protection for underground or underwater installation. Improved plant availability – sensor compliant with industry-specific requirements. International drinking water approvals. Degree of protection IP68 (Type 6P enclosure). International drinking water approvals. Installation length: DVGW/ISO conform.
Transmitter features
Optimum usability – operation with mobile devices and SmartBlue app or display with touch screen. Simple, time-saving commissioning – guided parameterization in advance and in the field. Integrated verification – Heartbeat Technology. System integration with HART, Modbus RS485. Flexible operation with app and optional display.
Nominal diameter range
DN 25 to 3000(1 to 120")
Wetted materials
Liner material hard rubber: 0 to +80 °C (+32 to +176 °F) Liner material polyurethane: –20 to +50 °C (–4 to +122 °F) Liner material PTFE: –20 to +90 °C (–4 to +160 °F) Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022)
0.5 m3/h to 263000 m3/h (2.5gal/min to 1665 Mgal/d)
Max. process pressure
PN 40, Class 300, 20K
Medium temperature range
Liner material hard rubber: 0 to +80 °C (+32 to +176 °F) Liner material polyurethane: –20 to +50 °C (–4 to +122 °F) Liner material PTFE: –20 to +90 °C (–4 to +194°F)
Ambient temperature range
-40 to 60°C (-40 to 140°F)
Sensor housing material
DN 25 to 300 (1 to 12"): AlSi10Mg, coated DN 350 to 2000 (14 to 78"): Carbon steel with protective varnish
Transmitter housing material
Polycarbonat; AlSi10Mg, coated
Degree of protection
Compact version: IP66/67, type 4X enclosure Sensor remote version (standard): IP66/67, type 4X enclosure Sensor remote version (option): IP68, type 6P enclosure, with protective varnish according to EN ISO 12944 C5-M/Im1/Im2/Im3
Display/Operation
LCD display with touch & auto rotate
Outputs
4-20 mA HART (active/passive), Pulse/frequency/switch output Modbus RS485, 4-20 mA
Digital communication
HART, MODBUS RS485, IO-Link
Power supply
DC 24 V AC 100 to 230 V AC 100 to 230 V / DC 24 V (non-hazardous area)
Hazardous area approvals
CSA, GP, KC
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
Pressure approvals and certificates
CRN, PED
Material certificates
3.1 material
Hygienic approvals and certificates
Drinking water approvals: ACS, KTW-BWGL, NSF 61, WRAS BS 6920
WirelessHART and/or Bluetooth® communication interface, Operating frequency: 2.4 GHz (ISM band), Transmission range under reference conditions: WirelessHART communication - up to 200 m (656 ft), Bluetooth communication - up to 40 m (131 ft)
WirelessHART and/or Bluetooth® communication interface, Operating frequency: 2.4 GHz (ISM band), Transmission range under reference conditions: WirelessHART communication - up to 200 m (656 ft), Bluetooth communication - up to 40 m (131 ft)