Oversigt over specifikationer
-
Accuracy
class A acc. to IEC 60751
-
Response time
depending on configuration
-
Max. process pressure (static)
at 20 °C: 40 bar (580 psi)
-
Operating temperature range
PT100:
-50 °C … 200 °C
(-58 °F … 392 °F) -
Max. immersion length on request
up to 15.5" (317,5mm)
others on request
Anvendelsesområde
This iTHERM thermometer has been designed to meet the basic requirements of the Food & Beverages and Life Sciences industries at the best price. It offers a variety of versions within a clearly segmented standard product. The result: Time and cost savings by simple and fast product selection. The device uses basic technology with features such as a fixed, non-replaceable insert, a wide range of process connections and international certification at an excellent value for money.
Specially designed for use in hygienic and aseptic applications in the Food & Beverages and Life Sciences industries
Measuring range: –50 to +200 °C (–8 to +392 °F)
Pressure range up to 40 bar (580 psi)
Protection class: up to IP69K
Can be used in non-hazardous areas
Fordele
-
Excellent value for money and fast delivery
-
User-friendly and reliable from product selection to maintenance
-
International certification: hygiene standards as per 3-A® , EHEDG, ASME BPE, FDA, TSE Certificate of Suitability
-
Wide range of process connections
Videoer
Fundamental
-
Enkle produkter
- Nemme at vælge, installere og betjene
Teknisk ydeevne
Enkelhed
-
Standardprodukter
- Pålidelige og robuste med lav vedligeholdelse
Teknisk ydeevne
Enkelhed
-
Specialiserede produkter
- Designet til krævende applikationer
Teknisk ydeevne
Enkelhed
Variabel
FLEX valg | Teknisk ydeevne | Enkelhed |
---|---|---|
Fundamental Få dækket dine basale målebehov |
Teknisk ydeevne
|
Enkelhed
|
Lean Administrer nemt dine kerneprocesser |
Teknisk ydeevne
|
Enkelhed
|
Extended Optimer dine processer med innovative teknologier |
Teknisk ydeevne
|
Enkelhed
|
Xpert Til de mest udfordrende applikationer |
Teknisk ydeevne
|
Enkelhed
Variabel |
Forgænger
-
-
Tekniske oplysninger (TI)
TI Weld-in adapter, process adapter and flanges
Level, pressure and temperature measurement
EN DA 25/03/202415/09/202328/10/202130/07/202119/06/2020Sprog:
Engelsk
Version:
25/03/2024
Filstørrelse:
1.1 MB
Filnavn:
TI00426FEN_2524.pdf
-
-
-
Tekniske oplysninger (TI)
iTHERM TM402
Resistance thermometer for hygienic and aseptic applications
EN DA 30/08/202214/01/202131/10/201804/08/2017Sprog:
Engelsk
Version:
30/08/2022
Filstørrelse:
1.7 MB
Filnavn:
TI01349TEN_0422-00.pdf
-
-
-
Betjeningsvejledning (BA)
Modulopbyggede hygiejniske termometre
Universelle modulopbyggede termometre med RTD-indsats til hygiejniske
anvendelserEN DA 20/01/2020Sprog:
Dansk
Version:
20/01/2020
Filstørrelse:
592.6 KB
Filnavn:
BA02023TDA_0120.pdf
-
-
-
Installationsanvisninger (EA)
Installation Instructions iTHERM TM402, TM412
Imperial hygienic RTD thermometer
Sprog:
Engelsk
Version:
04/07/2017
Filstørrelse:
821.1 KB
Filnavn:
EA01221T09EN_0117.pdf
-
-
-
Specialdokumentation (SD)
Device viewer
Technical documentation in other languages
Sprog:
Engelsk
Version:
14/07/2021
Filstørrelse:
478.5 KB
Filnavn:
SD02429R09EN_0121.pdf
-
-
-
Specialdokumentation (SD)
SD Hygienic process connection types
Supplement to TM311, TM371, TM372, TM401, TM411, TM402, TM412, TT411,
TT412, TE411, TK40, TMR35, DTT35, TTR35Sprog:
Engelsk
Version:
15/09/2023
Filstørrelse:
800.3 KB
Filnavn:
SD03119TEN_0123-00.pdf
-
-
-
PU (udgivelse)
iTHERM TM4xx Innovatives modulares Thermometer
Topmoderne, modulare RTD-Temperaturfühler
für hygienische und aseptische AnwendungenSprog:
Tysk
Version:
14/09/2022
Filstørrelse:
1.4 MB
Filnavn:
PU01224T_09_DE_02.22 TM4xx.pdf
-
-
-
PU (udgivelse)
Ecograph T RSG35 Universeller Datenmanager
Prozesswerte überwachen, anzeigen,
aufzeichnen und übertragen
Der Ecograph T RSG35 Datenmanager ist eine einfache und dennoch
in höchstem Maße effektive Lösung zur manipulationssicheren
Datenaufzeichnung.
Das intelligente Gerät lässt sich perfekt überall dort
integrieren, wo Prozessparameter angezeigt, aufgezeichnet, analysiert
und überwacht werden müssen.Sprog:
Tysk
Version:
14/09/2022
Filstørrelse:
2.1 MB
Filnavn:
PU01244T_09_DE_01.17 RSG35.pdf
-
-
-
PU (udgivelse)
iTHERM TM4xx Innovative modular temperature assemblies
Advanced, modularRTD temperature probes
for hygienic and aseptic applicationsSprog:
Engelsk
Version:
09/08/2022
Filstørrelse:
1.4 MB
Filnavn:
PU01224T_09_EN_02.22 TM4xx.pdf
-
-
-
Innovation (IN)
iTHERM Thermometer TM401, TM402, TM411, TM412
Modulare iTHERM Thermometer im hygienegerechten Design für die
Lebensmittel- und pharmazeutische IndustrieSprog:
Tysk
Version:
03/08/2017
Filstørrelse:
1.1 MB
Filnavn:
IN00016TDE_0217.pdf
-
-
-
Innovation (IN)
iTHERM thermometers TM401, TM402, TM411, TM412
Modular iTHERM thermometers with hygienic design
for the Food & Beverage and Life Sciences industriesSprog:
Engelsk
Version:
03/08/2017
Filstørrelse:
1.1 MB
Filnavn:
IN00016TEN_0217.pdf
-
-
-
Producenterklæring
Product family: Accessories: Pipe thermowell, Accessories: Inserts, PROCESS RTD HYGIENIC, RTD thermometer
Product root: TK40-, TM371-, TM372-, TM401-, TM402-, TM411-,
TM412-, TMR35-, TS111-, TS212-, TT411-, TT412-
Declaration number: HE_00886_01.17
Additional information: TSE compliance, animal fat freeEN DA 23/10/2017Sprog:
Engelsk
Version:
23/10/2017
Filstørrelse:
160.7 KB
Filnavn:
HE_00886_0117.pdf
-
-
-
Producenterklæring
Product family: Process RTD hygienic
Product root: TM402-
Declaration number: HE_01262_01.20
Manufacturer specification: RoHS
Additional information: China RoHSSprog:
Kinesisk
Version:
22/03/2020
Filstørrelse:
324.9 KB
Filnavn:
HE_01262_01.20 China RoHS TM402.pdf
-
-
-
Producenterklæring
Product family: Accessories: Pipe thermowell, Magphant, Process RTD hygienic, RTD thermometer
Product root: DTT35-, TK40-, TM311-, TM371-, TM372-, TM401-, TM402-, TM411-, TM412-, TMR35-, TT411-, TT412-, TTR35-
Declaration number: HE_01097_02.23
Manufacturer specification: Food hygieneSprog:
Engelsk
Version:
28/03/2022
Filstørrelse:
367.6 KB
Filnavn:
HE_01097_02.23 MD-22010 19002.pdf
-
-
-
Producenterklæring
Product family: Accessories: Pipe thermowell, Magphant, PROCESS RTD HYGIENIC, RTD-THERMOMETER
Product root: DTT35-, TK40-, TM311-, TM371-, TM372-, TM401-,
TM402-, TM411-, TM412-, TMR35-, TT411-, TT412-, TTR35-
Declaration number: HE_00099_05.15
Manufacturer specification: Food hygiene, 10/2011, 1935/2004EN DA 10/12/2020Sprog:
Engelsk
Version:
10/12/2020
Filstørrelse:
1.8 MB
Filnavn:
HE_00099_05.15.pdf
-
-
-
Producenterklæring
Product family: Process RTD hygienic
Product root: TK40-, TM401-, TM402-, TM411-, TM412-, TS111-,
TS112-, TT411-, TT412-
Declaration number: MD-12028A-9Sprog:
Engelsk
Version:
10/01/2013
Filstørrelse:
872.7 KB
Filnavn:
MD-12028a_09_e.pdf
-
-
-
Producenterklæring
Product family: Accessories: Bar stock thermowell, Accessories: Pipe thermowell, Accessories: Inserts, Magphant, Process RTD general purpose, Process RTD hygienic, RTD thermometer
Product root: DTT31-, DTT35-, TK40-, TM101-, TM111-, TM121-, TM131-, TM311-, TM371-, TM372-, TM401-, TM402-, TM411-, TM412-, TMR35-,
TS111-, TS212-, TT131-, TT151-, TT411-, TT412-
Declaration number: HE_01494_01.21
Manufacturer specification: Food hygiene
Additional information: BSE, TSESprog:
Engelsk
Version:
27/07/2023
Filstørrelse:
266 KB
Filnavn:
HE_00886_07_17.pdf
-
-
-
Producenterklæring
Product family: Process RTD hygienic
Product root: TM401-, TM402-, TM411-, TM412-
Declaration number: TM4XX SUPPLIERS DOC
Manufacturer specification: RoHS, Explosion protection, EMC
Additional information: ACMA, AustraliaSprog:
Engelsk
Version:
12/04/2024
Filstørrelse:
143 KB
Filnavn:
TM4xx Suppliers Dec of Conformity_2404012.pdf
-
-
-
FDA-erklæring
Product family: Accessories: Pipe thermowell, Magphant, PROCESS RTD HYGIENIC, RTD-THERMOMETER
Product root: DTT35-, TK40-, TM311-, TM371-, TM372-, TM401-,
TM402-, TM411-, TM412-, TMR35-, TT411-, TT412-, TTR35-
Declaration number: FDA_00127_03.17
FDA specification: SealingEN DA 20/07/2020Sprog:
Engelsk
Version:
20/07/2020
Filstørrelse:
450.8 KB
Filnavn:
FDA_00127_03.17.pdf
-
-
-
EU-erklæring
Product family: Low cost RTD general purpose, Process RTD direct contact, Process RTD direct in contact, Process RTD general purpose , Process RTD heavy duty, Process RTD hygienic, Process TC direct contact, Process TC direct in contact, Process TC general purpose, Process TC heavy duty, RTD thermometer, TC heavy duty
Product root: TAF11-, TAF12D-, TAF12S-, TAF12T-, TAF16-, TC10-, TC12-, TC13-, TC15-, TC61-, TC62-, TC63-, TC65-, TC66-, TC88-, TEC42
0-, TH11-, TH12-, TH13-, TH14-, TH15-, TH17-, TH18-, TH27-, TH51-, TH52-, TH53-, TH54-, TH55-, TH56-, TM101-, TM111-, TM112-, TM121-
, TM131-, TM151-, TM152-, TM401-, TM402-, TM411-, TM412-, TMT142C-, TMT142R-, TMT162C-, TMT162R-, TR10-, TR11-, TR12-, TR13-, TR15-,
TR24-, TR25-, TR44-, TR45-, TR46-, TR47-, TR48-, TR61-, TR62-, TR63-, TR65-, TR66-, TR88-, TSC310-, TSM187-, TSM487-, TST187-, TST3
10-, TST40N-, TST410-, TST414-, TST41N-, TST434-, TST434B-, TST487-, TST602-, TST90-
Declaration number: EC_00136_04.24EN DA 20/02/2024Sprog:
Engelsk
Version:
20/02/2024
Filstørrelse:
150.6 KB
Filnavn:
EC_00136_04.24.pdf
-