Prøv at søge efter nøgleord, ordre- eller produktkode eller serienummer, f.eks. “CM442” eller “Teknisk information”
Indtast mindst 2 tegn for at starte søgningen.

Prosonic FDU80

Produktbillede af: Prosonic FDU80

Dette produkt er ikke længere tilgængeligt.

Se den nye generation i afsnittet med forgængere/efterfølgere, eller kontakt den lokale Endress+Hauser-afdeling.

Details

  • Measuring principle

    Ultrasonic

  • Characteristic / Application

    Separated version with field housing and control room instrumentation

  • Supply / Communication

    4-wire (HART, Profibus DP, RS 485)

  • Accuracy

    +/- 0.2 % of set measuring range

  • Ambient temperature

    -40 °C ... 60 °C
    (-40 °F ... 140 °F)

  • Process temperature

    -40 °C ... 60 °C
    (-40 °F ... 140 °F)

  • Process pressure absolute / max. overpressure limit

    0.7 bar ... 2 bar abs
    (10 psi ... 29 psi)

  • Main wetted parts

    PP

  • Process connection

    G / NPT 1"

  • Blocking distance

    0.3 m (1 ft)

  • Application

    Application

  • Max. measurement distance

    Max. measurement distance

  • Communication

    Transmitter:
    4 ... 20 mA HART
    Profibus DP
    RS485

  • Certificates / Approvals

    ATEX
    CSA
    FM
    TIIS
    IECEx

  • Options

    Heated version

  • Components

    Transmitter:
    FMU860 / FMU862

  • Successor

    FDU91

  • Application limits

    Application limits

  • Measuring principle

    Ultrasonic

  • Characteristic / Application

    Separated version with field housing and control room instrumentation

  • Supply / Communication

    4-wire (HART, Profibus DP, RS 485)

  • Accuracy

    +/- 0.2 % of set measuring range

  • Ambient temperature

    -40 °C ... 60 °C

  • Process temperature

    -40 °C ... 60 °C

  • Process pressure absolute / max. overpressure limit

    0.7 bar ... 2 bar abs

  • Main wetted parts

    PP

  • Process connection

    G / NPT 1"

  • Blocking distance

    0.3 m

  • Max. measurement distance

    2 m

  • Certificates / Approvals

    ATEX
    FM
    CSA

  • Components

    Transmitter
    FMU860 / FMU862

  • Successor

    FDU91

  • Application limits

    Take notice of range diagram

  • Measuring principle

    Ultrasonic

  • Product headline

    Version with separate transmitter in fieldhousing
    Cost effective solution for very big diameters

  • Sensor features

    Optional with heating system

  • Nominal diameter range

    Unlimited (open channel)

  • Max. measurement error

    Low accuracy

  • Measuring range

    Unlimited(measuring distance 0,3...5m)

  • Max. process pressure

    atm.

  • Medium temperature range

    -20...60°C

  • Degree of protection

    IP68

  • Display/Operation

    Transmitter:
    Two line liquid
    Crystal display
    Push buttons

  • Outputs

    4...20mA HART

  • Inputs

    Transmitter

  • Digital communication

    Profibus DP
    RS485

  • Hazardous area approvals

    ATEX
    FM
    CSA

Dokumenter / Vejledninger / Software

Tilbehør / Reservedele

Nr
Order code
Specification
  • Afløser

    • Enkle produkter

    • Nemme at vælge, installere og betjene

    Teknisk ydeevne

    Enkelhed

    • Standardprodukter

    • Pålidelige og robuste med lav vedligeholdelse

    Teknisk ydeevne

    Enkelhed

    • Avancerede produkter

    • Funktionelle og praktiske

    Teknisk ydeevne

    Enkelhed

    • Specialiserede produkter

    • Designet til krævende applikationer

    Teknisk ydeevne

    Enkelhed

    Variabel

    FLEX valg Teknisk ydeevne Enkelhed
    • F
    • L
    • E
    • X

    Fundamental

    Få dækket dine basale målebehov

    Teknisk ydeevne
    Enkelhed
    • F
    • L
    • E
    • X

    Lean

    Administrer nemt dine kerneprocesser

    Teknisk ydeevne
    Enkelhed
    • F
    • L
    • E
    • X

    Extended

    Optimer dine processer med innovative teknologier

    Teknisk ydeevne
    Enkelhed
    • F
    • L
    • E
    • X

    Xpert

    Til de mest udfordrende applikationer

    Teknisk ydeevne
    Enkelhed

    Variabel