Prøv at søge efter nøgleord, ordre- eller produktkode eller serienummer, f.eks. “CM442” eller “Teknisk information”
Indtast mindst 2 tegn for at starte søgningen.

Proline Promag W 10
Electromagnetic flowmeter

Picture of electromagnetic flowmeter Proline Promag W 10 for basic water and wastewater applications ©Endress+Hauser

Proline Promag W 10 with lap-joint flanges for basic water and wastewater applications

Picture of electromagnetic flowmeter Proline Promag W 10 for basic water and wastewater applications ©Endress+Hauser

Proline Promag W 10 for basic water and wastewater applications

Picture of electromagnetic flowmeter Proline Promag W 10 as a remote version ©Endress+Hauser

Proline Promag W 10 with remote transmitter for basic water and wastewater applications

Proline 10 – uncompromisingly simple

The Electromagnetic Flow Measuring Principle

Flowmeter for basic water and wastewater applications with easy-to-use operation concept

Thanks to its international approvals (e.g. for drinking water), Promag W serves a wide variety of applications. It is available as both compact or remote version. With its straightforward hard- and software design, Promag W 10 simplifies every step in its life cycle from engineering to servicing at usual Endress+Hauser quality. Heartbeat Technology ensures measurement reliability and compliant verification.

  • Enkle produkter

  • Nemme at vælge, installere og betjene

Teknisk ydeevne

Enkelhed

  • Standardprodukter

  • Pålidelige og robuste med lav vedligeholdelse

Teknisk ydeevne

Enkelhed

  • Avancerede produkter

  • Funktionelle og praktiske

Teknisk ydeevne

Enkelhed

  • Specialiserede produkter

  • Designet til krævende applikationer

Teknisk ydeevne

Enkelhed

Variabel

FLEX valg Teknisk ydeevne Enkelhed
  • F
  • L
  • E
  • X

Fundamental

Få dækket dine basale målebehov

Teknisk ydeevne
Enkelhed
  • F
  • L
  • E
  • X

Lean

Administrer nemt dine kerneprocesser

Teknisk ydeevne
Enkelhed
  • F
  • L
  • E
  • X

Extended

Optimer dine processer med innovative teknologier

Teknisk ydeevne
Enkelhed
  • F
  • L
  • E
  • X

Xpert

Til de mest udfordrende applikationer

Teknisk ydeevne
Enkelhed

Variabel

  • Oversigt over specifikationer

    • Max. measurement error

      Volume flow (standard): ±0.5 % o.r. ± 1 mm/s (0.04 in/s)

    • Measuring range

      9 dm³/min to 162 000 m³/h (2.5 gal/min to 100 000 gal/min)

    • Medium temperature range

      Liner material hard rubber: 0 to +80 °C (+32 to +176 °F)
      Liner material polyurethane: –20 to +50 °C (–4 to +122 °F)
      Liner material PTFE: –20 to +90 °C (–4 to +160°F)

    • Max. process pressure

      PN 40, Class 300, 20K

    • Wetted materials

      Liner material hard rubber: 0 to +80 °C (+32 to +176 °F)
      Liner material polyurethane: –20 to +50 °C (–4 to +122 °F)
      Liner material PTFE: –20 to +90 °C (–4 to +160 °F)
      Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022)

please wait Loading alternative products

Hurtigvalg

Vælg blandt de foreslåede muligheder
Salgspris
  • <%label%>
  • <%feature%>
  • Process Connection
  • <%message%>

eller

Individuel konfiguration

Fortsæt dit valg blandt alle muligheder
  • Fordele

    • Reliable measurement at constant accuracy with 0 x DN inlet run without pressure loss

    • Flexible engineering – sensor with fixed or lap-joint process connections

    • Application fitness – EN ISO 12944 corrosion protection for underground or underwater installation

    • Improved plant availability – sensor compliant with industry-specific requirements

    • Optimum...

  • Anvendelsesområde

    • The bidirectional measuring principle is virtually independent of pressure, density, temperature and viscosity.

    • Suitable for elementary measurement tasks such as raw water intake.

    Device properties

    • International drinking water approvals

    • Degree of protection...

Funktioner og specifikationer

Tilbage

Details

  • Measuring principle

    Electromagnetic

  • Product headline

    Flowmeter for basic water and wastewater applications with easy-to-use operation concept.
    Reliable measurement at constant accuracy with 0 x DN inlet run without pressure loss.
    Suitable for elementary measurement tasks such as raw water intake.

  • Sensor features

    Flexible engineering – sensor with fixed or lap-joint process connections. Application fitness – EN ISO 12944 corrosion protection for underground or underwater installation. Improved plant availability – sensor compliant with industry-specific requirements.
    International drinking water approvals. Degree of protection IP68 (Type 6P enclosure). International drinking water approvals. Installation length: DVGW/ISO conform.

  • Transmitter features

    Optimum usability – operation with mobile devices and SmartBlue app or display with touch screen. Simple, time-saving commissioning – guided parameterization in advance and in the field. Integrated verification – Heartbeat Technology.
    System integration with HART, Modbus RS485. Flexible operation with app and optional display.

  • Nominal diameter range

    DN 25 to 2400 (1 to 90")

  • Wetted materials

    Liner material hard rubber: 0 to +80 °C (+32 to +176 °F)
    Liner material polyurethane: –20 to +50 °C (–4 to +122 °F)
    Liner material PTFE: –20 to +90 °C (–4 to +160 °F)
    Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022)

  • Measured variables

    Volume flow, conductivity, mass flow

  • Max. measurement error

    Volume flow (standard): ±0.5 % o.r. ± 1 mm/s (0.04 in/s)

  • Measuring range

    9 dm³/min to 162 000 m³/h (2.5 gal/min to 100 000 gal/min)

  • Max. process pressure

    PN 40, Class 300, 20K

  • Medium temperature range

    Liner material hard rubber: 0 to +80 °C (+32 to +176 °F)
    Liner material polyurethane: –20 to +50 °C (–4 to +122 °F)
    Liner material PTFE: –20 to +90 °C (–4 to +160°F)

  • Ambient temperature range

    -40 to 60°C (-40 to 140°F)

  • Sensor housing material

    DN 25 to 300 (1 to 12"): AlSi10Mg, coated
    DN 350 to 2000 (14 to 78"): Carbon steel with protective varnish

  • Transmitter housing material

    Polycarbonat; AlSi10Mg, coated

  • Degree of protection

    Compact version: IP66/67, type 4X enclosure
    Sensor remote version (standard): IP66/67, type 4X enclosure
    Sensor remote version (option): IP68, type 6P enclosure, with protective varnish according to EN ISO 12944 C5-M/Im1/Im2/Im3

  • Display/Operation

    LCD display with touch & auto rotate

  • Outputs

    4-20 mA HART (active/passive), Pulse/frequency/switch output
    Modbus RS485, 4-20 mA

  • Digital communication

    HART, MODBUS RS485

  • Power supply

    DC 24 V
    AC 100 to 230 V
    AC 100 to 230 V / DC 24 V (non-hazardous area)

  • Hazardous area approvals

    CSA, GP

  • Metrological approvals and certificates

    Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
    Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)

  • Pressure approvals and certificates

    CRN, PED

  • Material certificates

    3.1 material

  • Hygienic approvals and certificates

    Drinking water approvals: ACS, KTW/W270, NSF 61, WRAS BS 6920

Dokumenter / Vejledninger / Software

Tilbehør / Reservedele

Nr
Order code
Specification
  • 38
    • Nr 38 Order code 71505739

      Kit S+T-DAT Promag 10, Non-haz/Exd/Z2

      Electronic storage module unprogrammed Usage: Promag 10. Consists of: S+T-DAT.

  • 33
    • Nr 33 Order code XPD0060-

      ISEM, standard, HART, Promag 10, nEx

      Usage: Promag 10. Consists of: ISEM (sensor electronic module) V316-00.

    • Nr 33 Order code XPD0061-

      ISEM, standard, Modbus, Promag 10, nEx

      Usage: Promag 10. Consists of: ISEM (sensor electronic module) V316-00.

  • 46
    • Nr 46 Order code 71505743

      Kit ISEM ribbon cable, 10,Non-haz/Exd/Z2

      Usage: Promag/Promass 10, transmitter housing.

  • 33
    • Nr 33 Order code XPD0062-

      ISEM,enhanced,HART,Promag 10, nEx/Z2/Exd

      Usage: Promag 10. Consists of: ISEM (sensor electronic module) V313-00.

    • Nr 33 Order code XPD0063-

      ISEM,enhanced,Modb.,Promag 10,nEx/Z2/Exd

      Usage: Promag 10. Consists of: ISEM (sensor electronic module) V313-00.

  • 45
    • Nr 45 Order code 71505745

      Kit connection terminals, 10

      Consists of: Connection terminal 2-Pol., Connection terminal 6-Pol.

  • 44
    • Nr 44 Order code 71323264

      Kit connection board,Promag D/P/W,10/500

      Usage: Promag P 10 Ex, D/W 10 Non-haz, Promag P/W 500 Ex, Sensor connection housing. Consists of: connection board, cover to connection board.

  • 30
    • Nr 30 Order code XPD0080-

      HART, 24VDC, nEx, Alu, 10

      Electronic module E401. Usage: Promag 10, Promass 10. Consists of: Module cartridge, power supply module, I/O module

    • Nr 30 Order code XPD0081-

      HART, 100-230VAC, nEx, Alu, 10

      Electronic module E403. Usage: Promag 10, Promass 10. Consists of: Module cartridge, power supply module, I/O module

    • Nr 30 Order code XPD0082-

      HART, 100-230VAC/24VDC, nEx, Alu, 10

      Electronic module E408. Usage: Promag 10, Promass 10. Consists of: Module cartridge, power supply module, I/O module

    • Nr 30 Order code XPD0084-

      Mbus,100-230VAC/24VDC, nEx/Exd/Z2,Alu,10

      Electronic module E411. Usage: Promag 10, Promass 10. Consists of: Module cartridge, power supply module, I/O module

  • 50
    • Nr 50 Order code XPD0087-

      Display w/o LCD, SmartBlue app, 10

      Usage: Promag 10, Promass 10. Consists of: Display module A400.

    • Nr 50 Order code XPD0088-

      Display LCD, SmartBlue app, 10

      Usage: Promag 10, Promass 10. Consists of: Display module A401.

    • Nr 50 Order code XPD0089-

      Display LCD, touch, SmartBlue app, 10

      Usage: Promag 10, Promass 10. Consists of: Display module A401.

  • 21
    • Nr 21 Order code 71505748

      Kit cover, blind ,Alu,Non-haz/ Z2/ Div.2

      Usage: Promag/Promass 10, transmitter housing Alu. Consists of: cover blind Alu, O-Ring 110,70x3,53 HNBR.

  • 20
    • Nr 20 Order code 71505749

      Kit cover, glass,Alu,N-haz/Z2/Div.2/Exde

      Usage: Promag/Promass 10, transmitter housing Alu. Consists of: cover sight glass Alu, O-Ring 110,70x3,53 HNBR.

  • 70
    • Nr 70 Order code 71505752

      Kit cover gasket, glass/blind, Alu, 10

      Usage: Promag/Promass 10, transmitter housing Alu. Consists of: 10x O-Ring 110,70x3,53 HNBR.

  • 23
    • Nr 23 Order code 71323038

      Kit cover, wall mount, Alu, Ex

      Usage: Promag 10, Promag/Promass/Prosonic Flow 500, wall mount transmitter Alu, connection compartment. Consists of: cover Alu, O-Ring 88,50x3,53 HNBR.

  • 75
    • Nr 75 Order code 71323042

      Kit cover gasket, wall mount, Ex

      Usage: Promag 10, Promag/Promass/Prosonic Flow 500, wall mount transmitter Alu/cast, connection compartment. Consists of: 10x O-Ring 88,50x3,53 HNBR.

  • 24
    • Nr 24 Order code 71228796

      Kit cover, remote, Alu

      Usage: Promag 10/500, Promag/Promass/Prosonic Flow/t-mass 500 digital, Promag 400/800(C), (C) = generation index C, sensor connection housing. Consists of: cover Alu, O-Ring 113,90x3,53 HNBR.

    • Nr 24 Order code 71188176

      Kit cover plastic, remote, Promag L/P/W

      Usage: Promag 10/400/500/800, Promag 400/800(C), (C) = generation index C, sensor connection housing. Consists of: cover plastic coated, O-Ring 91,67 x 3,53 FKM.

    • Nr 24 Order code 71188176

      Kit cover plastic, remote, Promag L/P/W

      Usage: Promag 10/400/500/800, Promag 400/800(C), (C) = generation index C, sensor connection housing. Consists of: cover plastic coated, O-Ring 91,67 x 3,53 FKM.

    • Nr 24 Order code 71188176

      Kit cover plastic, remote, Promag L/P/W

      Usage: Promag 10/400/500/800, Promag 400/800(C), (C) = generation index C, sensor connection housing. Consists of: cover plastic coated, O-Ring 91,67 x 3,53 FKM.

    • Nr 24 Order code 71188176

      Kit cover plastic, remote, Promag L/P/W

      Usage: Promag 10/400/500/800, Promag 400/800(C), (C) = generation index C, sensor connection housing. Consists of: cover plastic coated, O-Ring 91,67 x 3,53 FKM.

  • 73
    • Nr 73 Order code 71228798

      Kit housing gaskets, remote, Alu

      Usage: Promag 10/500, Promag 500 digital, Promag 400/800(C), (C) = generation index C, sensor connection housing. Consists of: O-Ring 113,90x3,53 HNBR for cover, gasket EPDM for housing/sensor L/P/W, O-Ring 29,87x1,78 HNBR for sensor plug.

  • 72
    • Nr 72 Order code 71188179

      Kit cover gasket, plastic, Promag L/P/W

      Usage: Promag 10/400/500/800, Promag 400/800(C), (C) = generation index C, sensor connection housing. Consists of: 10x O-Ring 91,67 x 3,53 FKM.

    • Nr 72 Order code 71188179

      Kit cover gasket, plastic, Promag L/P/W

      Usage: Promag 10/400/500/800, Promag 400/800(C), (C) = generation index C, sensor connection housing. Consists of: 10x O-Ring 91,67 x 3,53 FKM.

    • Nr 72 Order code 71188179

      Kit cover gasket, plastic, Promag L/P/W

      Usage: Promag 10/400/500/800, Promag 400/800(C), (C) = generation index C, sensor connection housing. Consists of: 10x O-Ring 91,67 x 3,53 FKM.

    • Nr 72 Order code 71188179

      Kit cover gasket, plastic, Promag L/P/W

      Usage: Promag 10/400/500/800, Promag 400/800(C), (C) = generation index C, sensor connection housing. Consists of: 10x O-Ring 91,67 x 3,53 FKM.

  • 71
    • Nr 71 Order code 71505753

      Kit interface gaskets, Alu, Promag 10

      Usage: Promag 10, transmitter housing/sensor or transmitter housing/wall mount. Consists of: 5x O-Ring 88,50x3,53 HNBR for interface, 5x O-Ring 29,87x1,78 HNBR for for sensor plug.

  • 13
    • Nr 13 Order code 71276494

      Kit securing clamp, screw

      Usage: Promass 100, Promag 100, Prosonic Flow E 100/E Heat, CNGmass, LPGmass, LNGmass, Promag/Promass 500, Promag 10, Promag/Promass/Prosonic Flow/t-mass 500 digital, Promag 400/800(C), (C) = generation index C, sensor connection housing. Consists of: cover clamp, screw M4x16.

  • 87
    • Nr 87 Order code 71502730

      Kit weather protection cover, 10

      Usage: Promag 10, 5DBB,5HBB,5PBB,5WBB, Promass 10, 8KBB

Downloads