Capacitance
Point level detection
Nivector FTI26
For all types of powdered and fine-grained solids especially in the food industry
The Nivector FTI26 is a cost-efficient point level switch for solids in the food industry and powder applications in all industries. The capacitance device convinces with the best build-up performance in class and a high sensitivity. All industry compliant certificates are available. In addition, the FTI26 is industry 4.0 ready with IO-Link communication.
- F
- L
- E
- X
-
Standardprodukter
- Pålidelige og robuste med lav vedligeholdelse
Teknisk ekspertise
Enkelhed
-
Specialiserede produkter
- Designet til krævende applikationer
Teknisk ekspertise
Enkelhed
Variabel
FLEX valg | Teknisk ekspertise | Enkelhed |
---|---|---|
Fundamental Få dækket dine basale målebehov |
Teknisk ekspertise
|
Enkelhed
|
Lean Administrer nemt dine kerneprocesser |
Teknisk ekspertise
|
Enkelhed
|
Extended Optimer dine processer med innovative teknologier |
Teknisk ekspertise
|
Enkelhed
|
Xpert Til de mest udfordrende applikationer |
Teknisk ekspertise
|
Enkelhed
Variabel |
-
Oversigt over specifikationer
-
Process temperature
-40°C...80°C
(-40°F...176°F)
-
Hurtigvalg
Individuel konfiguration
-
Fordele
-
Easy installation even in tight conditions or where access is restricted thanks to the compact design
Fulfillment of all relevant hygienic requirements (3A, EHEDG, FDA, EG1935/2004); cleanable (IP69)
IO-Link reduces costs and complexity with an easy...
-
-
Anvendelsesområde
For MIN or MAX detection in silos with powdered and fine-grained solids, like plastic granules, grain, sugar, spices, coffee powder, laundry detergent
Process connections: G1" thread, Tri-Clamp 2" via adapter
Temperature: -20 to +80°C (-4 to +176°F)
...
Dokumenter / Vejledninger / Software
-
Nivector FTI26
Technical Information
Point level switch for powdered and fine-grained solids
Technical Information (TI) -
Nivector FTI26
Operating Instructions
Point level switch for powdered and fine-grained solids; IO-Link
Operating Instruction (BA) -
Nivector FTI26
Operating Instructions
Nivector FTI26; Point level switch for powdered and fine-grained solids
Operating Instruction (BA) -
Nivector FTI26
Brief Operating Instructions
Nivector FTI26; Point level switch for powdered and fine-grained solids
Short Instruction (KA)10/19Engelsk -
Nivector FTI26
Control Drawing
Safety Instructions
Capacitive Level Measurement
Ex Safety Instructions (XA) -
Nivector FTI26
ATEX:
II 1/3 D Ex ta/tc IIIC T100°C Da/Dc
IECEx:
Ex ta/tc IIIC T100°C Da/DcEx Safety Instructions (XA) -
Nivector FTI26
Ex ta IIIC T100°C Da
Ex tc IIIC T100°C Dc XEx Safety Instructions (XA) -
3-A certificate
Sensors and Sensor Fittings and Connections
No. 459 / 74-06 (3-A)
Certificate (ZE) -
3-A certificate
Level sensing devices for dry products
Soliphant M FTM50, FTM51
Nivector FTI26
No. 1834 / 50-01 (3-A)
Certificate (ZE) -
Declaration of Compliance
Nivector FTI26
with process Connection "WDJ"
HE_00977Certificate (ZE) -
Declaration of Compliance
Protector for Nivector FTI26
HE_00976Certificate (ZE) -
Hygiene approvals
Level and pressure measuring devices
Special Documentation (SD) -
Protector G1 ½, R1 ½ or NPT1 ½
Level measurement
Special Documentation
Protector G1 ½, R1 ½ or NPT1 ½
Special Documentation (SD) -
Kontermutter/Lock nut G1
Level measurement
Special Documentation
Kontermutter/Lock nut G1
Special Documentation (SD) -
Schutzhaube
Level measurement
Special Documentation
Schutzhaube
Special Documentation (SD) -
Mounting hints for weld-in adapter
Level and pressure measurement
Special Documentation
Mounting hints for weld-in adapter
Special Documentation (SD) -
Application conditions for seals and plastics in the food sector
Level measurement, pressure measurement
Special Documentation
Application conditions for seals and plastics in the food sector
Special Documentation (SD) -
IODD Single, IODD_IOL_LE_Nivector_0x91FE_0x01_0x01, 28.01.2019 (Level, Nivector, 0x91FE)
IO-Link,
IO-Link Version: AnyIO Device Description (IODD)1.00.00Language neutral -
IODD Single, IODD_IOL_LE_Nivector_0x91FE_0x02_0x01, 08.02.2019 (Level, Nivector, 0x91FE)
IO-Link,
IO-Link Version: AnyIO Device Description (IODD)1.00.00Language neutral -
Nivector
Product Code: FTI26-
Declaration Number: FDA_00211_02.19FDA DeclarationTysk , Engelsk -
Nivector
Product Code: FTI26-
Declaration Number: EC_00670_02.18EU DeclarationTysk , Engelsk , fr -
Nivector
Product Code: FTI26-
Declaration Number: EC_00668_03.18EU DeclarationTysk , Engelsk , fr -
Nivector
Product Code: FTI26-
Region/Country: Russia, Russia (Declaration of Conformity), Russia (TR CU)
Approval Agency: EAC
Approval Number: EAEC_N_D-DE.NA10.B.0137718MiscellaneousRussisk -
Nivector
Product Code: FTI26-
Region/Country: Europe (ATEX)
Approval Agency: SEV
Protection: Ex ta/tc IIIC Txxx°C Da/DcExplosion ProtectionTysk , Engelsk -
Nivector
Product Code: FTI26-
Region/Country: International (IECEx)
Approval Agency: SEV
Protection: Ex ta/tc IIIC Txxx°C Da/DcExplosion ProtectionEngelsk -
Nivector
Product Code: FTI26-
Region/Country: Europe (ATEX)
Approval Agency: SEV
Protection: Ex ta/tc IIIC Txxx°C Da/DcExplosion ProtectionTysk , Engelsk -
Nivector
Product Code: FTI26-
Region/Country: Canada, USA
Approval Agency: CSAExplosion ProtectionEngelsk -
Nivector
Product Code: FTI26-
Protection: Ex ta/tc IIIC Txxx°C Da/DcExplosion ProtectionRussisk -
Nivector
Product Code: FTI26-
Region/Country: International (IECEx)
Approval Agency: SEV
Protection: Ex ta/tc IIIC Txxx°C Da/DcExplosion ProtectionEngelsk -
Prosonic S, Nivector, Micropilot, LIQUITREND, Liquipoint, Liquiphant M, Liquicap M, Levelflex, Deltapilot S, Deltapilot M, Deltabar S, Deltabar, Ceraphant, Cerabar T, Cerabar S, Cerabar M, Cerabar
Product Code: QMW43-, PTP33B-, PMP75-, PMP55-, PMP51-, PMP23-, PMC71-, PMC51-, FTW33-, FTW23-, FTL51H-, FTL50H-, FTL33-, FDU91F-, FMB50-, FMB70-, FMD71-, FMD72-, FMD78-, FMI51-, FMP52-, FMP53-, FMR52-, FMR62-, FTI26-, FTI51-
Region/Country: USA
Approval Agency: 3-A Sanitary StandardsHygienic EquipmentEngelsk -
Nivector
Product Code: FTI26-
Region/Country: USA
Approval Agency: 3-A Sanitary StandardsHygienic EquipmentEngelsk -
Micropilot, Micropilot S, Minicap, Nivector, Prosonic M, Prosonic S, Prosonic T, Pumpenschutz, Solicap M, Solicap S, Soliphant M, Soliphant T, SYSTEM, Doppelstabsonde, Dreistabsonde, Einstabsonde, Levelflex, Liquicap M, Liquicap T, Liquiphant, Liquiphant FailSafe, Liquiphant M, Liquiphant S, Liquipoint, Liquipoint T, LIQUITREND
Product Code: FTL51C-, FTL51B-, FTL51-, FTL50H-, FTL50-, FTL41-, FTL33-, FTL31-, FTI77-, FTI56-, FTI55-, FTI52-, FTI51-, FTI26-, FTC968Z-, FTC262-, FTC260-, FMU44-, FMU43-, FTL51H-, FTL62-, FTL64-, FTL70-, FTL71-, FTL80-, FTL81-, FTL85-, FTM20-, FTM21-, FTM50-, FTM51-, FTM52-, FTW23-, FTW31-, FTW32-, FTW33-, NMR81-, NMR84-, QMW43-, FMU42-, 11362Z-, 11363Z-, 11371-, 11375Z-, 11961Z-, FDU90-, FDU91-, FDU91F-, FDU92-, FDU93-, FDU95-, FMI21-, FMI51-, FMI52-, FMP50-, FMP51-, FMP52-, FMP53-, FMP54-, FMP55-, FMU41-, FMU40-, FMU30-, FMR67-, FMR62-, FMR60-, FMR57-, FMR56-, FMR540-, FMR54-, FMR532-, FMR53-, FMR52-, FMR51-, FMR50-, FMR20-, FMR10-, FMP57-, FMP56-
Approval Agency: TÜVPressure EquipmentTysk , Engelsk -
Nivector
Product Code: FTI26-
Region/Country: Canada, USA
Approval Agency: CSAOrdinary Location Product SafetyEngelsk
Tilbehør / Reservedele
-
-
Order code 71267011
Test magnet
Usage: FTL20/FTL20H, FTL31/FTL33, FTL50/FTL50H/FTL51/FTL51H, FTW23, FTW33.
-
Order code 71395785
Protector G1-1/2, PBT-GF, FTI26
Mounting adapter, thread G1-1/2. Material: PBT-GF, FDA listed. Temp.: -20...+80oC. Immersion: 63mm. :: Protection against abrasion. :: No solids flow at Nivector-exchange. Usage: FTI26.
-
Order code 71395862
Protector R1-1/2, PBT-GF, FTI26
Mounting adapter, thread R1-1/2. Material: PBT-GF, FDA listed. Temp.: -20...+80oC. Immersion: 63mm. ::Protection against abrasion. ::No solids flow at Nivector-exchange. Usage: FTI26.
-
Order code 71416936
Protector NPT1-1/2, PBT-GF, FTI26
Mounting adapter, thread G1-1/2. Material: PBT-GF, FDA listed. Temp.: -20...+80oC, immersion: 63mm. :: Protection against abrasion. :: No solids flow at Nivector-exchange. Usage: FTI26.
-
Order code 71395793
Process adapter G1>Clamp-2, 316L, 3.1
Process adapter G1. Material: 316L. Seal: EPDM 15.54x2.62mm. FDA, EHEDG, 3-A conform. Usage: FTI26.
-
Order code 71395797
Weld-in adapter G1, 316L, 3.1, FTI26
Material: 316L. Seal: EPDM 70 O-ring. FDA, EHEDG, 3-A compliant. Usage: FTI26.
-
Order code 71395801
Locking nuts G1, plastic PA
Mounting aid. Material: plastic PA. Wrench size: 41mm. Usage: FDU90/FDU91/FDU92, FMR10/FMR20, FTC968 AC, FTI26.
-
Order code 71395803
Ex-protection cover
Material: PC. Mandatory for Ex-version. W/o Ex-protection cover dust Ex-protection not guaranteed! Usage: FTI26, PMC21, PMP21.
-
Order code 52018763
M12 socket,90o,316L,IP69,LED,cable L=5m
M12x1 plug socket 90o, 4-pin, integrated LED. 5m cable, PVC, 316L screw lock. Hygienic applications, IP69. Usage: FTL31/OFTL31, FTL33/OFTL33, FTW23/OFTW23, FTW33/OFTW33, FTI26/OFTI26, QMW43.
-