Ultrasonic measurement
Time-of-Flight
Prosonic FDU95
Ultrasonic sensor for level measurement for connection to FMU9x (measuring range up to 45m)
The FDU95 ultrasonic sensor for continuous, non-contact and maintenance-free level measurement of powdery to coarse bulk materials. The measurement is unaffected by dielectric constant, density or humidity and also unaffected by build-up due to the self-cleaning effect of sensors. Suited for explosion hazardous areas. Maximum measuring range in solids 45m (148ft).
-
Fordele
Integrated temperature sensor for Time-of-Flight correction. Accurate measurements are possible, even if temperature changes are present
Suited for rough ambient conditions thanks to separate installation from the transmitter
(up to 300m)Reduced build-...
-
Anvendelsesområde
Sensor for continuous, non-contact level measurement of bulk materials in silos, on belts, stockpiles and in crushers. Typically used in measurements in low structural heights.
Process connection: Thread
Temperature: -40 to +80°C or +150°C (-40 to +176°...
Dokumenter / Vejledninger / Software
-
Prosonic S
FDU90/91/91F/92/93/95
Technical Information/Operating Instructions
Ultrasonic sensors for non-contact continuous level and flow measurement
Technical Information (TI) -
Alignment Unit FAU40
Technical Information
Mounting accessory for ultrasonic sensors with separate drive electronics
Technical Information (TI) -
Prosonic S FMU95
Transmitter for 5 or 10 ultrasonic sensors
Operating Instruction (BA) -
Safety Instructions
Prosonic S FDU90, FDU91, FDU91F, FDU92, FDU93, FDU95
II 3 G Ex nA IIC T5 Gc (FDU90) II 3 G Ex nA IIC T6 Gc (FDU91-93/95, FDU91F) II 3 D Ex tc IIIC Txx°C Dc EG 05 024
Ex Safety Instructions (XA) -
Safety Instructions
Prosonic S FDU93, FDU95
Ex tD A20/21 IP65 T GYJ16.1246 (NEPSI)
Ex Safety Instructions (XA) -
Safety Instructions
Prosonic S FDU93, FDU95
II 1/2 D Ex ta/tb IIIC Txx°C Da/Db IP68 II 2 D Ex tb IIIC Txx°C Db IP68 BVS 05 ATEX E 009
Ex Safety Instructions (XA) -
Safety Instructions
Prosonic S FDU90, FDU91, FDU91F, FDU92, FDU93, FDU95
Ex ma IIC T5 Gb Ex ma IIC T6 Gb Ex tD A20/21 IP65 T GYJ16.1246 (NEPSI)
Ex Safety Instructions (XA) -
Safety Instructions
Prosonic S FDU90, FDU91, FDU91F, FDU92, FDU93, FDU95
II 2 G Ex ma IIC T5 Gb (FDU90) II 2 G Ex ma IIC T6 Gb (FDU91/91F/92/93/95) II 1/2 D Ex ta/tb IIIC Txx°C Da/Db IP68 II 2 D Ex tb IIIC Txx°C Db IP68 BVS 05 ATEX E 009
Ex Safety Instructions (XA) -
Safety Instructions
Prosonic S FDU90/91, FDU91F, FDU92/93/95
Ex ma IIC T5 Gb (FDU90) Ex ma IIC T6 Gb (FDU91/91F/92/93/95) Ex ta/tb IIIC Txx°C Da/Db IP65 Ex tb IIIC Txx°C Db IP65 TÜV 13.0893 X (INMETRO)
Ex Safety Instructions (XA) -
Prosonic S FDU93, FDU95, FDU96
IECEx BVS 08.0012 Ex ta/tb IIIC Txx°C Da/Db IP68 Ex tb IIIC Txx°C Db IP68
Ex Safety Instructions (XA) -
Prosonic S FDU90, FDU91, FDU91F, FDU92, FDU93, FDU95, FDU96
IECEx BVS 08.0012 Ex ma IIC Tx Gb Ex ta/tb IIIC Txx°C Da/Db IP68 Ex tb IIIC Txx°C Db IP68
Ex Safety Instructions (XA) -
Ultrasonic Sensors
Instructions for shortening the sensor cable
Special Documentation (SD) -
Fachbericht:40 Jahre Ultraschall-Füllstandmesstechnik
Fachbericht:Dieses Jahr feiert Endress+Hauser das 40jährige Bestehen der Ultraschall-Füllstandmesstechnik, mit der bis heute mehr als 500.000 Anwendungen gelöst wurden. Dass diese Technik auch heute noch viele Vorteile bietet, zeigt die aktuelle Entwicklung von Neuprodukten.
Publications (PU)11/09Tysk -
Ultrasonic transmitter FDU95 and FMU90 processes bulk pellet feed for
farm animals
Suitable for narrow silos filled with corn, barley wheat and soy where environment is dusty.
Case Studies (CS)07/10Engelsk -
Level measurement in polymer station with ultrasonic level sensor
For the different treatment processes, wastewater plants produce huge amounts of sewage sludge annually. Since this must be disposed of through landfill or incineration, it is essential to try to render residual sludge as dry as possible.
Case Studies (CS)06/11Engelsk -
Prosonic S Transmitter via HART to the PlantPAx Process Automation
System
System using a ControlLogix 1756 HART Analog Input Module Integration Document
System Partner (SP)01/09Engelsk -
Prosonic S, FDU 9x
(FDU90, FDU91 FDU92 FDU93 FDU95 FDU96)
Ultraschall-Füllstandmessstelle mit Sensor und abgesetztem Messumformer. Füllstand-Messwertaufnehmer zur kontinuierlichen Füllstandmessung in offenen Behältern.
Tender Text11/16Tysk -
Radar or ultrasonic measurement
Animation DE 960x540 mp4
Animation07/16Tysk -
Radar or ultrasonic measurement
Animation FR 1280x720 mp4
Animation07/16fr -
Radar or ultrasonic measurement
Animation flv EN
Animation06/15Engelsk -
Radar or ultrasonic measurement
Animation mp4 EN
Animation06/15Engelsk -
Prosonic S
Product Code: FDU95- Declaration Number: HE_00840_01.17 Manufacturer Specification: RoHS
Manufacturer DeclarationKinesisk -
Prosonic S
Product Code: FDU90-, FDU91-, FDU91F-, FDU92-, FDU93-, FDU95-, FDU96- Declaration Number: EG 05 024
EU DeclarationTysk , Engelsk , fr -
Prosonic S
Product Code: FDU90-, FDU91-, FDU91F-, FDU92-, FDU93-, FDU95-
EU DeclarationTysk , Engelsk , fr -
Prosonic S
Product Code: FDU90-, FDU91-, FDU91F-, FDU92-, FDU93-, FDU95- Declaration Number: EC_00196_03.16
EU DeclarationTysk , Engelsk , fr -
Prosonic M, Prosonic S
Product Code: FDU90-, FDU91-, FDU92-, FDU93-, FDU95-, FMU40-, FMU41-, FMU42-, FMU43-, FMU44-, FMU90-, FMU95- Region/Country: Russia (TR CU) Approval Agency: EAC Approval Number: TC № RU D-DE.AL32.B.07214
MiscellaneousRussisk -
Prosonic M, Prosonic S
Product Code: FDU90-, FDU91-, FDU91F-, FDU92-, FDU93-, FDU95-, FMU40-, FMU41-, FMU42-, FMU43-, FMU44-, FMU90-, FMU95- Region/Country: Russia (TR CU) Approval Agency: EAC Approval Number: TС RU D-DE.MU62.B.02534
MiscellaneousRussisk -
Prosonic M, Prosonic S, Prosonic T
Product Code: FMU95-, FMU90-, FMU44-, FMU43-, FMU42-, FMU41-, FMU40-, FMU30-, FDU96-, FDU95-, FDU93-, FDU92-, FDU91-, FDU90- Region/Country: Russia (TR CU) Approval Agency: EAC Approval Number: TC BY_112 11.01. TP020 003 127
MiscellaneousRussisk -
Soliphant T, Soliphant M, Solicap S, Solicap M, Prosonic S, Prosonic M, Nivector, Minicap, Micropilot, Levelflex
Product Code: FTM52-, FTM51-, FTM50-, FTM21-, FTM20-, FTI77-, FTI56-, FTI55-, FTC968Z-, FTC968-, FTC262-, FTC260-, FMU95-, FMU90-, FMU44-, FMU43-, FMU42-, FMU41-, FMU40-, FMR67-, FMR57-, FMR56-, FMP57-, FMP56-, FDU95-, FDU93-, FDU92-, FDU91F-, FDU91-, FDU90- Region/Country: Russia (Declaration of Conformity) Approval Number: RU D-DE.MO10.B.05551
MiscellaneousRussisk -
Soliphant T, Soliphant M, Solicap S, Solicap M, Prosonic S, Prosonic M, Nivector, Minicap, Micropilot, Levelflex
Product Code: FTM52-, FTM51-, FTM50-, FTM21-, FTM20-, FTI77-, FTI56-, FTI55-, FTC968Z-, FTC968-, FTC262-, FTC260-, FMU95-, FMU90-, FMU44-, FMU43-, FMU42-, FMU41-, FMU40-, FMR67-, FMR57-, FMR56-, FMP57-, FMP56-, FDU95-, FDU93-, FDU92-, FDU91F-, FDU91-, FDU90- Region/Country: Russia (Declaration of Conformity) Approval Number: RU D-DE.MO10.B.05554
MiscellaneousRussisk -
Prosonic S
Product Code: FDU90-, FDU91-, FDU91F-, FDU92-, FDU93-, FDU95- Region/Country: China Approval Agency: NEPSI Category: zone 0, zone 20,21 Protection: Ex tD A20/A21 IP6X IIIC Txxx°C Da/Db, Ex ma II T5, Ex ma II T6
Explosion ProtectionKinesisk -
Prosonic S
Product Code: FDU90-, FDU91-, FDU91F-, FDU92-, FDU93-, FDU95-, FDU96- Approval Agency: FM Category: I/1,2/A,B,C,D/T5, I/1,2/A,B,C,D/T6, II,III/1,2/E,F,G/T4A
Explosion ProtectionEngelsk -
Prosonic S
Product Code: FDU90-, FDU91-, FDU91F-, FDU92-, FDU93-, FDU95-, FDU96- Region/Country: Canada, USA Approval Agency: CSA Category: I/2/A,B,C,D/T5, I/2/A,B,C,D/T3C, I,II,III/1,2/A,B,C,D,E,F,G/T5, I,II,III/1,2/A,B,C,D,E,F,G/T6, II,III/1/E,F,G/T5, II,III/1/E,F,G/T3C
Explosion ProtectionEngelsk -
Prosonic M, Prosonic S, Prosonic T
Product Code: FMU95-, FMU90-, FMU44-, FMU43-, FMU42-, FMU41-, FMU40-, FMU30-, FDU95-, FDU93-, FDU92-, FDU91F-, FDU91-, FDU90- Region/Country: Russia (TR CU) Approval Agency: EAC Protection: Ex d [ia], Ex ia, Ex m, Ex nA, Ex t, Ex ta/tc, Ex ta/tb
Explosion ProtectionRussisk -
Prosonic S
Product Code: FDU90-, FDU91-, FDU91F-, FDU92-, FDU93-, FDU95-, FDU96- Region/Country: Canada, USA Approval Agency: CSA Category: I,II,III 1 ABCDEFG Protection: 6P, Exm
Explosion ProtectionEngelsk -
Prosonic S
Product Code: FDU96-, FDU95-, FDU93-, FDU92-, FDU91F-, FDU91-, FDU90- Region/Country: Europe (ATEX) Approval Agency: EXAM (DMT, BVS) Category: II 2 G, II 1/2 D, II 2 D Protection: Ex ta/tb IIIC Txx°C Da/Db IP65, Ex tb IIIC Txx°C Db IP65, Ex ma IIC T6/T5 Gb
Explosion ProtectionTysk , Engelsk -
Prosonic S
Product Code: FDU90-, FDU91-, FDU91F-, FDU92-, FDU93-, FDU95-, FDU96- Region/Country: Europe (ATEX) Approval Agency: EXAM (DMT, BVS) Category: II 2 D, II 2 G, II 1/2 D Protection: Ex tb IIIC Txxx°C Db, Ex ta/tb IIIC Txxx°C Da/Db, Ex ma IIC T5 Gb, Ex ma IIC T6 Gb
Explosion ProtectionTysk , Engelsk -
Prosonic S
Product Code: FDU90-, FDU91-, FDU91F-, FDU92-, FDU93-, FDU95- Region/Country: Brazil Approval Agency: TÜV Protection: Ex m, Ex tb
Explosion ProtectionPortugisisk -
Prosonic S
Product Code: FDU90-, FDU91-, FDU91F-, FDU92-, FDU93-, FDU95-, FDU96- Approval Agency: FM Category: I,II,III 1,2 ABCDEFG Protection: DIP, S
Explosion ProtectionEngelsk -
Prosonic S
Product Code: FDU90-, FDU91-, FDU91F-, FDU92-, FDU93-, FDU95-, FDU96- Region/Country: International (IECEx) Approval Agency: IECEx Protection: Ex tb IIIC Txxx°C Db, Ex ta/tb IIIC Txxx°C Da/Db, Ex ma IIC T5 Gb, Ex ma IIC T6 Gb
Explosion ProtectionEngelsk -
Micropilot S, Liquiphant S, Levelflex, Micropilot, Liquiphant M, Minicap, Nivector, Prosonic M, Prosonic S, Prosonic T, Pumpenschutz, Solicap M, Solicap S, Soliphant M, Soliphant T, SYSTEM, Liquipoint T, Liquipoint, Liquiphant FailSafe, Liquiphant, Liquicap T, Liquicap M, Einstabsonde, Dreistabsonde, Doppelstabsonde
Product Code: FTL51-, FMP54-, FMP52-, FMR52-, FMR54-, FMP57-, FMP55-, FMP51-, FMR51-, FMR57-, FMP53-, FMR56-, FMP56-, FMR53-, FMR50-, FMP50-, FMU41-, FMU42-, FTL51H-, FTL50H-, FMU43-, FMU44-, FTL51C-, FTL70-, FMU40-, FMI52-, FTL50-, FTL71-, FTM51-, FTI52-, FMR532-, FTL81-, FMI51-, FMR533-, FTI51-, FTL85-, FTM52-, FTL33-, FTL31-, FTI77-, FTI56-, FTI55-, FTC968Z-, FTC262-, FTC260-, FTL80-, FTM20-, FTM21-, FTM50-, FTW23-, FTW31-, FTW32-, FTW33-, FTW360-, NMR84-, NMR81-, 11263-, 11362Z-, 11363Z-, 11375Z-, 11961Z-, FDU90-, FDU91-, FDU91F-, FDU92-, FDU95-, FDU96-, FDU93-, FMI21-, FMU30-, FMR540-, FMR530-, FMR10-, FMR20- Approval Agency: TÜV
Pressure EquipmentTysk , Engelsk -
Prosonic M, Prosonic S
Product Code: FDU91F-, FDU92-, FDU93-, FDU95-, FDU96-, FMU40-, FMU41-, FMU42-, FMU43-, FMU44-, FMU90-, FMU95- Region/Country: Russia (GOST) Approval Agency: Rosstandart Approval Number: DE.C.29.004.A № 50999
MetrologyRussisk -
Prosonic M, Prosonic S, Prosonic T
Product Code: FMU95-, FMU90-, FMU44-, FMU43-, FMU42-, FMU41-, FMU40-, FMU30-, FDU96-, FDU95-, FDU93-, FDU92-, FDU91F-, FDU91-, FDU90- Region/Country: Kazakhstan Approval Agency: KazInMetr Approval Number: 12134
MetrologyRussisk -
Prosonic M, Prosonic S, Prosonic T
Product Code: FMU95-, FMU90-, FMU44-, FMU43-, FMU42-, FMU41-, FMU40-, FMU30-, FDU96-, FDU95-, FDU93-, FDU92-, FDU91-, FDU90- Region/Country: Belarus Approval Agency: BEL Approval Number: 9773
MetrologyRussisk
-
Forgænger