Vibronic
Point level detection
Liquiphant FTL85
Coated point level switch for liquids for FailSafe overfill prevention
Liquiphant FTL85 is a coated point level switch for use in hazardous areas with all international certificates. FailSafe overfill prevention in applications with functional safety up to SIL3 with one device. With high corrosion-resistant coating made of enamel, ECTFE and various PFA materials. Reliable measurement values, not affected by: changing media properties, flow, turbulences, gas bubbles, foam, vibrations or build-up.
-
Fordele
Use in safety systems requiring functional safety to SIL3 in accordance with IEC 61508 Ed.2.0/ IEC 61511-1/ISA 84-1 and DIN EN ISO 13849
Proof test: proof testing interval up to 12 years, Slave devices tested at the press of a button
Permanent self-...
-
Anvendelsesområde
Point level switch for liquids up to SIL3.
Process connections: Threads and flanges
Temperature: -50 to +150°C (-76 to +300°F)
Pressure: -1 to +40bar (-14.5 to +580psi)
Sensor length: Extension pipe up to 3m (9.8ft)
Sensor material: Enamel, ECTFE and...
Dokumenter / Vejledninger / Software
-
Liquiphant FailSafe FTL80, FTL81, FTL85
Technical Information
Vibronic Point level switch for liquids
Technical Information (TI) -
Liquiphant FailSafe FTL80, FTL81, FTL85
Operating Instructions
Vibronic Point level switch for liquids
Operating Instruction (BA) -
Cover for housing T13 electronic compartment with sight glas
Installation instruction
Liquicap M, Solicap M, Liquphant M/S/FailSafe, Soliphant M
Mounting Instruction (EA) -
Cover for housing F27
Installation instruction
Liquihant M/S, Soliphant M, Liquicap M, Solicap M/S
Mounting Instruction (EA) -
Graphite gaskets
Installation instruction
Liquiphant M, LIquiphant S, Liquiphant FailSafe
Mounting Instruction (EA) -
Cover for Housing F15
Installation instruction
LIquiphant M/S/Fail Safe, Soliphant M, Cerabar M, Deltapilot M
Mounting Instruction (EA) -
Electronics on Liquiphant M/S/FailSafe
Installation instruction
Liquiphant M/S/FailSafe
Mounting Instruction (EA) -
Cover for Housing F17
Installation instruction
LIquiphant M/S/Fail Safe, Soliphant M
Mounting Instruction (EA) -
Diagnostics plug
Installation instruction
Liquiphant M/S/FailSafe, Soliphant T/M
Mounting Instruction (EA) -
Cover for housing F13
Installation instruction
Liquiphant M/S, Soliphant M, Liquicap M, Solicap M/S
Mounting Instruction (EA) -
Cover for Housing F16
Installation instruction
LIquiphant M/S/Fail Safe, Soliphant M
Mounting Instruction (EA) -
Cover for housing T13 electronic compartment
Installation instruction
Liquiphant M/S, Soliphant M, Liquicap M, Solicap M/S
Mounting Instruction (EA) -
Cover for housing T13 terminal compartment
Installation instruction
Liquiphant M/S, Soliphant M, Liquicap M, Solicap M/S
Mounting Instruction (EA) -
Safety Instructions
Liquiphant FailSafe FTL80, FTL81, FTL85
Control Drawing XP + NI
Ex Safety Instructions (XA) -
Safety Instructions
Liquiphant FailSafe FTL80, FTL81, FTL85
ATEX: II 1 G Ex ia IIC T6 Ga, II 1/2 G Ex ia IIC T6 Ga/Gb IECEx: Ex ia IIC T6 Ga, Ex ia IIC T6 Ga/Gb FM 12ATEX0036X; IECEx FMG 12.0014X
Ex Safety Instructions (XA) -
Safety Instructions
Liquiphant FailSafe FTL80, FTL81, FTL85
Control Drawing IS + XP
Ex Safety Instructions (XA) -
Safety Instructions
Liquiphant FailSafe FTL80, FTL81, FTL85
ATEX: II 1/2 G Ex d IIC T6 Ga/Gb, II 1/2 D Ex ta IIIC T80°C Da/Db IECEx: Ex d IIC T6 Ga/Gb, Ex ta IIIC T80°C Da/Db FM 12ATEX0036X; IECEx FMG 12.0014X
Ex Safety Instructions (XA) -
Safety Instructions
Liquiphant FailSafe FTL80, FTL81, FTL85
Control Drawing NI
Ex Safety Instructions (XA) -
Safety Instructions
Liquiphant FailSafe FTL80, FTL81, FTL85
Control Drawing IS
Ex Safety Instructions (XA) -
Safety Instructions
Liquiphant FailSafe FTL80, FTL81, FTL85
ATEX: II 1/2 G Ex ia IIC T6 Ga/Gb, II 1/2 D Ex ia IIIC T80°C Da/Db IECEx: Ex ia IIC T6 Ga/Gb, Ex ia IIIC T80°C Da/Db FM 12ATEX0036X; IECEx FMG 12.0014X
Ex Safety Instructions (XA) -
Safety Instructions
Liquiphant FailSafe FTL80, FTL81, FTL85
Control Drawing IS
Ex Safety Instructions (XA) -
Liquiphant FailSafe FTL80, FTL81, FTL85
NEPSI:
Ex ia IIC T2-T6 Ga
Ex ia IIC T2-T6 Ga/Gb
Safety Instructions
Vibronic Limit Switches, Liquids
Ex Safety Instructions (XA) -
Safety Instructions
Liquiphant FailSafe FTL80, FTL81, FTL85
Control Drawing NI
Ex Safety Instructions (XA) -
Liquiphant FailSafe FTL80, FTL81, FTL85
NEPSI:
Ex d IIC T2-T6 Ga/Gb
Safety Instructions
Vibronic Limit Switches, Liquids
Ex Safety Instructions (XA) -
Liquiphant FailSafe FTL80, FTL81, FTL85
EAC:
Ga/Gb Ex d IIC T6 X
Safety Instructions
Vibronic Limit Switches, Liquids
Ex Safety Instructions (XA) -
Safety Instructions
Liquiphant FailSafe FTL80, FTL81, FTL85
ATEX: II 1/2 G Ex de IIC T6 Ga/Gb IECEx: Ex de IIC T6 Ga/Gb FM 12ATEX0036X; IECEx FMG 12.0014X
Ex Safety Instructions (XA) -
Safety Instructions
Liquiphant FailSafe FTL80, FTL81, FTL85
ATEX: II 1/2 G Ex d IIC T6 Ga/Gb IECEx: Ex d IIC T6 Ga/Gb FM 12ATEX0036X; IECEx FMG 12.0014X
Ex Safety Instructions (XA) -
Liquiphant FailSafe FTL80, FTL81, FTL85
NEPSI:
Ex nA IIC T2-T6 Ga/Gc
Safety Instructions
Vibronic Limit Switches, Liquids
Ex Safety Instructions (XA) -
Liquiphant FailSafe FTL80, FTL81, FTL85
NEPSI:
Ex de IIC T2-T6 Ga/Gb
Safety Instructions
Vibronic Limit Switches, Liquids
Ex Safety Instructions (XA) -
Safety Instructions
Liquiphant FailSafe FTL80, FTL81, FTL85
ATEX: II 1/3 G Ex nA IIC T6 Ga/Gc IECEx: Ex nA IIC T6 Ga/Gc FM 12ATEX0036X; IECEx FMG 12.0014X
Ex Safety Instructions (XA) -
Liquiphant FailSafe FTL80, FTL81, FTL85
EAC:
0Ex ia IIC T6 Ga X
Ga/Gb Ex ia IIC T6 X
Safety Instructions
Vibronic Limit Switches, Liquids
Ex Safety Instructions (XA) -
Safety Instructions
Liquiphant FailSafe FTL80, FTL81, FTL85
ATEX: II 1/2 G Ex ia IIC T6 Ga/Gb, II 1/2 G Ex d IIC T6 Ga/Gb IECEx: Ex ia IIC T6 Ga/Gb, Ex d IIC T6 Ga/Gb FM 12ATEX0036X; IECEx FMG 12.0014X
Ex Safety Instructions (XA) -
Safety Instructions
Liquiphant FailSafe FTL80, FTL81, FTL85
Control Drawing XP + NI
Ex Safety Instructions (XA) -
Liquiphant FailSafe FTL80, FTL81, FTL85
Allgemeine bauaufsichtliche Zulassung Z-65.11-507 (DIBt)
Standgrenzschalter (Schwingsonde) mit Messumformer als Teil von Überfüllsicherungen
Certificate (ZE) -
RFID TAG
Certificate/Declaration of Conformity
ATEX: II 2 G Ex ia IIC T6 Gb II 2 D Ex ia IIIC T80°C Db; IECEx: Ex ia IIC T6 Gb Ex ia IIIC T80°C Db IECEx EPS 15.0042X; EPS 15 ATEX 1 1011 X
Certificate (ZE) -
Liquiphant FailSafe FTL80, FTL81, FTL85
Allgemeine bauaufsichtliche Zulassung Z-65.40-508 (DIBt)
Leckagesonde (Schwingsonde) mit Messumformer als Anlageteil von Leckageerkennungssystemen
Certificate (ZE) -
RFID TAG
Special Documentation
RFID TAG Special Documentation
Special Documentation (SD) -
Liquiphant FailSafe FTL80, FTL81, FTL85,
Nivotester FailSafe FTL825
Functional Safety data sheet (SIL) / Datenblatt zur Funktionalen Sicherheit (SIL)
Special Documentation (SD) -
Functional Safety Manual (SIL)
Liquiphant FailSafe FTL80, FTL81, FTL85
Nivotester FailSafe FTL825
Operating minimum (e.g. dry run protection) and maximum monitoring (e.g. overfill protection) of all types of liquids in vessels to satisfy particular safety systems requirements as per IEC 61508 Edition 2.0
Special Documentation (SD) -
kurier 03-2012
Kundenmagazin: Sicherheit auf ganzer Linie
Customer Magazine (CM)11/12Tysk -
Fachartikel: Sicherheit hat einen Namen
Fachartikel: Liquiphant FailSafe FTL80/81/85 und Nivotester FTL825
Publications (PU)07/13Tysk -
Fachartikel: Sicherheit geht vor
Fachartikel: Fehlersichere Grenzstanddetektionen in Flüssigkeiten nach SIL3 realisieren
Publications (PU)07/13Tysk -
Mesure de niveau
Aperçu des produits pour des applications dans des liquides et des solides en vrac
Fields of Activities (FA)03/17fr -
Level measurement
Product overview for applications in liquids and bulk solids
Fields of Activities (FA)03/17Engelsk -
Füllstandmesstechnik
Produktübersicht für Anwendungen in Flüssigkeiten und Schüttgütern
Fields of Activities (FA)03/17Tysk -
Catálogo Medición y Detección de nivel
Gama de productos para aplicaciones con líquidos y sólidos
Fields of Activities (FA)03/17Spansk -
Level measurement
Product overview for applications in liquids and bulk solids
Fields of Activities (FA)03/17Engelsk -
Komplettlösung Überfüllsicherung
Endress+Hauser – Ihr kompetenter Partner für mehr Automatisierungslösungen rund um das Wasserhaushaltsgesetzt
Competence Brochure (CP)09/15Tysk -
Die Liquiphant-Familie
Grenzstanddetektion in Flüssigkeiten mit dem Messprinzig Vibronik
Competence Brochure (CP)07/16Tysk -
The Liquiphant family
Point level detection in liquids using the vibronic measuring principle
Competence Brochure (CP)07/16Engelsk -
Liquiphant FailSafe
Detección de nivel para el máximo grado de seguridad
Innovations (IN)06/12Spansk -
Liquiphant FailSafe
Point level switch for the maximum degree of safety
Innovations (IN)03/13Engelsk -
Liquiphant FailSafe
Der Grenzstandschalter für ein Höchstmaß an Sicherheit
Innovations (IN)03/13Tysk -
Liquiphant FailSafe
American version: Point level switch for the maximum degree of safety
Innovations (IN)01/13Engelsk -
Animation Messprinzip Vibronik
Animation DE mp4 1280x720
Animation10/12Tysk -
Animation Messprinzip Vibronik
Animation DE flv 480x270
Animation10/12Tysk -
Measuring Principle Vibronic
Animation EN flv 480x270
Animation09/12Engelsk -
Measuring Principle Vibronic
Animation EN mp4 1280x720
Animation09/12Engelsk -
Plant Safety
Animation FR 1280x720 mp4
Animation06/15fr -
Plant Safety
Animation EN mp4
Animation06/15Engelsk -
Animation Measuring Principle Vibronic FR
Animation FR flv 480x270
Animation05/13fr -
Measuring Principle Vibronic
Animation ES mp4 1280x720
Animation05/13Engelsk -
Measuring Principle Vibronic
Animation ES flv 480x270
Animation05/13Spansk -
Animation Measuring Principle Vibronic FR
Animation FR mp4 1280x720
Animation05/13fr -
Measuring Principle Vibronic
Animation IT flv 480x270
Animation01/13Italiensk -
Measuring Principle Vibronic
Animation IT mp4 1280x720
Animation01/13Italiensk -
Measuring Principle Vibronic
Animation TR mp4 1280x720
Video08/17Tyrkisk -
Liquiphant FailSafe
Product Code: FTL85- Declaration Number: HE_00804_01.17 Manufacturer Specification: RoHS
Manufacturer DeclarationKinesisk -
Liquiphant FailSafe
Product Code: FTL85- Declaration Number: FDA_00160_02.17
FDA DeclarationTysk , Engelsk -
Liquiphant
Product Code: FTL80-, FTL81-, FTL85-
EU DeclarationTysk , Engelsk , fr -
Liquiphant FailSafe
Product Code: FTL80-, FTL81-, FTL85- Declaration Number: EC_00098_03.15
EU DeclarationTysk , Engelsk , fr -
Liquiphant
Product Code: FTL80-, FTL81-, FTL85- Region/Country: China Approval Agency: ACMA Approval Number: EC12005A
MiscellaneousEngelsk -
Liquiphant, Liquiphant FailSafe, Liquiphant M, Liquiphant S, Liquiphant T
Product Code: FTL85-, FTL81-, FTL80-, FTL71-, FTL70-, FTL51C-, FTL51-, FTL50H-, FTL50-, FTL33-, FTL31-, FTL20H-, FTL20- Region/Country: Russia (TR CU) Approval Agency: EAC Approval Number: TC BY_112 11.01. TP020 003 127
MiscellaneousRussisk -
SYSTEM, Pumpenschutz, Nivotester FailSafe, Nivotester, Micropilot S, Micropilot, Liquipoint T, Liquiphant T, Liquiphant S, Liquiphant M, Liquiphant FailSafe, Liquiphant, Liquicap T, Liquicap M, Levelflex, Floating Switch
Product Code: FTL260-, FTL31-, FTL325N-, FTL325P-, FTL33-, FTL375P-, FTL50-, FTL50H-, FTL51-, FTL51C-, FTL51H-, FTL70-, FTL71-, FTL80-, FTL81-, FTL825-, FTL85-, FTS20-, FTW31-, FTW32-, FTW325-, FTW360-, NMR81-, NMR84-, FTI52-, FMI21-, FMI51-, FMI52-, FMP50-, FMP51-, FMP52-, FMP53-, FMP54-, FMP55-, FMR10-, FMR20-, FMR50-, FMR51-, FMR52-, FMR53-, FMR530-, FMR532-, FMR533-, FMR54-, FMR540-, FMR60-, FMR62-, FTC325-, FTI51- Region/Country: Russia (Declaration of Conformity) Approval Number: RU D-DE.MO10.B.05528
MiscellaneousRussisk -
Liquiphant, Liquiphant FailSafe, Liquiphant M, Liquiphant S, Liquiphant T
Product Code: FTL85-, FTL81-, FTL80-, FTL71-, FTL70-, FTL51H-, FTL51C-, FTL51-, FTL50X-, FTL50H-, FTL50-, FTL330L-, FTL330H-, FTL33-, FTL31-, FTL260-, FTL20H-, FTL20- Region/Country: Russia (TR CU) Approval Agency: EAC Approval Number: TС RU D-DE.MU62.B.02537
MiscellaneousRussisk -
SYSTEM, Pumpenschutz, Nivotester FailSafe, Nivotester, Micropilot S, Micropilot, Liquipoint T, Liquipoint, Liquiphant T, Liquiphant S, Liquiphant M, Liquiphant FailSafe, Liquiphant, Liquicap T, Liquicap M, Levelflex, Floating Switch, Einstabsonde, Dreistabsonde, Doppelstabsonde
Product Code: FTL70-, FTL51H-, FTL51C-, FTL51-, FTL50H-, FTL50-, FTL375P-, FTL33-, FTL325P-, FTL325N-, FTL31-, FTL260-, FTI52-, FTI51-, FTL71-, FTL80-, FTL81-, FTL825-, FTL85-, FTS20-, FTW23-, FTW31-, FTW32-, FTW325-, FTW33-, FTW360-, NMR81-, NMR84-, 11362Z-, 11363Z-, 11371-, 11375Z-, 11961Z-, FMI21-, FMI51-, FMI52-, FMP50-, FMP51-, FMP52-, FMP53-, FMP54-, FMP55-, FMR10-, FMR20-, FMR50-, FMR51-, FMR52-, FMR53-, FMR530-, FMR532-, FMR533-, FMR54-, FMR540-, FMR60-, FMR62-, FTC325- Region/Country: Russia (Declaration of Conformity) Approval Number: RU D-DE.MO10.B.05531
MiscellaneousRussisk -
Liquiphant, Liquiphant FailSafe, Liquiphant M, Liquiphant S, Liquiphant T, Nivotester, Nivotester FailSafe
Product Code: FTL85-, FTL825-, FTL81-, FTL80-, FTL71-, FTL70-, FTL51H-, FTL51C-, FTL51-, FTL50H-, FTL50-, FTL375P-, FTL330L-, FTL330H-, FTL33-, FTL325P-, FTL325N-, FTL31-, FTL260-, FTL20H-, FTL20-, FTC325- Region/Country: Russia (TR CU) Approval Agency: EAC Approval Number: TC № RU D-DE.AL32.B.07215
MiscellaneousRussisk -
Liquiphant
Product Code: FTL80-, FTL81-, FTL85- Region/Country: Canada, USA Approval Agency: CSA Category: I,II,III/1/A,B,C,D,E,F,G T6, I/zone 2, I,II,III/2/A,B,C,D,E,F,G T6, I/zone 0, I/zone 1 Protection: IS, XP, AEx/Ex d IIC T6 Gb, AEx/Ex ia IIC T6 Ga, AEx/Ex nA IIC T6 Gc, DIP, NI
Explosion ProtectionEngelsk -
Liquiphant
Product Code: FTL80-, FTL81-, FTL85- Region/Country: International (IECEx) Approval Agency: FM Protection: Ex d IIC T6 Ga/Gb, Ex ia IIC T6 Ga/Gb, Ex ia IIIC T080°C Da/Db, Ex nA IIC T6 Ga/Gc, Ex d e IIC T6 Ga/Gb, Ex ia IIC T6 Ga, Ex ta IIIC T080°C Da/Db
Explosion ProtectionEngelsk -
Liquiphant
Product Code: FTL80-, FTL81-, FTL85- Region/Country: China Approval Agency: NEPSI Protection: Ex d IIC T6...T2 Ga/Gb
Explosion ProtectionEngelsk , Kinesisk -
Liquiphant
Product Code: FTL80-, FTL81-, FTL85- Region/Country: China Approval Agency: NEPSI Protection: Ex d e IIC T6...T2 Ga/Gb
Explosion ProtectionEngelsk , Kinesisk -
Liquiphant FailSafe
Product Code: FTL80-, FTL81-, FTL85- Region/Country: Russia (TR CU) Approval Agency: EAC Protection: Ex d, Ex d e, Ex ia, Ex nA, Ex ta
Explosion ProtectionRussisk -
Liquiphant
Product Code: FTL80-, FTL81-, FTL85- Region/Country: China Approval Agency: NEPSI Protection: Ex ia IIC T6...T2 Ga, Ex ia IIC T6...T2 Ga/Gb
Explosion ProtectionEngelsk , Kinesisk -
Liquiphant
Product Code: FTL80-, FTL81-, FTL85- Region/Country: Canada, USA Approval Agency: FM Category: I/zone 0, I/zone 2, I,II,III/1/B,C,D,E,F/T6, I,II,III/1/A,B,C,D,E,F,G/T6 Protection: IS, NI, XP, AEx/Ex d IIC T6, AEx/Ex ia IIC T6, AEx/Ex nA IIC T6
Explosion ProtectionEngelsk -
Liquiphant
Product Code: FTL80-, FTL81-, FTL85- Region/Country: Europe (ATEX) Approval Agency: FM Category: II 1/2 D, II 1/2 G, II 1/3 G, II 1 G Protection: Ex d IIC T6 Ga/Gb, Ex d e IIC T6 Ga/Gb, Ex ia IIC T6 Ga, Ex ia IIC T6 Ga/Gb, Ex ia IIIC T080°C Da/Db, Ex nA IIC T6 Ga/Gc, Ex ta IIIC T080°C Da/Db
Explosion ProtectionEngelsk -
Liquiphant
Product Code: FTL80-, FTL81-, FTL85- Region/Country: China Approval Agency: NEPSI Protection: Ex nA IIC T6...T2 Ga/Gb
Explosion ProtectionEngelsk , Kinesisk -
Liquiphant, Nivotester
Product Code: FTL80-, FTL81-, FTL825-, FTL85- Region/Country: Germany Approval Agency: DIBt Approval Number: Z-65.40-508
Overfill PreventionTysk -
Liquiphant, Nivotester
Product Code: FTL80-, FTL81-, FTL825-, FTL85- Region/Country: Germany Approval Agency: DIBt Approval Number: Z-65.11-507
Overfill PreventionTysk -
Liquiphant, Liquiphant FailSafe, Nivotester
Product Code: FTL80-, FTL81-, FTL825-, FTL85- Region/Country: Germany Approval Agency: TÜV Approval Number: TÜV.ÜS3.18-056
Overfill PreventionTysk , Engelsk -
Liquiphant, Nivotester
Product Code: FTL80-, FTL81-, FTL825-, FTL85- Region/Country: Switzerland Approval Agency: SVTI Approval Number: 302.014.18
Overfill PreventionTysk -
Micropilot S, Liquiphant S, Levelflex, Micropilot, Liquiphant M, Minicap, Nivector, Prosonic M, Prosonic S, Prosonic T, Pumpenschutz, Solicap M, Solicap S, Soliphant M, Soliphant T, SYSTEM, Liquipoint T, Liquipoint, Liquiphant FailSafe, Liquiphant, Liquicap T, Liquicap M, Einstabsonde, Dreistabsonde, Doppelstabsonde
Product Code: FTL51-, FMP54-, FMP52-, FMR52-, FMR54-, FMP57-, FMP55-, FMP51-, FMR51-, FMR57-, FMP53-, FMR56-, FMP56-, FMR53-, FMR50-, FMP50-, FMU41-, FMU42-, FTL51H-, FTL50H-, FMU43-, FMU44-, FTL51C-, FTL70-, FMU40-, FMI52-, FTL50-, FTL71-, FTM51-, FTI52-, FMR532-, FTL81-, FMI51-, FMR533-, FTI51-, FTL85-, FTM52-, FTL33-, FTL31-, FTI77-, FTI56-, FTI55-, FTC968Z-, FTC262-, FTC260-, FTL80-, FTM20-, FTM21-, FTM50-, FTW23-, FTW31-, FTW32-, FTW33-, FTW360-, NMR84-, NMR81-, 11263-, 11362Z-, 11363Z-, 11375Z-, 11961Z-, FDU90-, FDU91-, FDU91F-, FDU92-, FDU95-, FDU96-, FDU93-, FMI21-, FMU30-, FMR540-, FMR530-, FMR10-, FMR20- Approval Agency: TÜV
Pressure EquipmentTysk , Engelsk -
Liquiphant FailSafe, Liquiphant M, Liquiphant S
Product Code: FTL85-, FTL81-, FTL80-, FTL71-, FTL70-, FTL51H-, FTL51C-, FTL51-, FTL50H-, FTL50- Region/Country: Canada (CRN) Approval Agency: CRN
Pressure EquipmentEngelsk -
Liquiphant, Nivotester
Product Code: FTL80-, FTL81-, FTL825-, FTL85- Region/Country: International Approval Agency: TÜV
Safety Integrity Level (SIL)Tysk , Engelsk -
Liquiphant FailSafe
Product Code: FTL80-, FTL81-, FTL85- Approval Agency: LR
MarineEngelsk -
Liquiphant FailSafe
Product Code: FTL80-, FTL81-, FTL85- Approval Agency: BV
MarineEngelsk -
Liquiphant FailSafe
Product Code: FTL81-, FTL85-, FTL80- Approval Agency: ABS
MarineEngelsk -
Liquiphant FailSafe
Product Code: FTL80-, FTL81-, FTL85- Region/Country: Canada, USA Approval Agency: CSA
Ordinary Location Product SafetyEngelsk