"Product Phased Out". Differential pressure, capacitive. Transmitter. Application: level, hydrostatic. Membrane: ceramic, flush mounted. Secondary process barrier. :: High long term stability. :: High reliability through process monitoring. :: High resistance to abrasion. :: Enhanced mechanical integrity. :: Modular.
Digital transmitter with ceramic measuring diaphragms Modular transmitter Long-term stability Enhanced safety via self diagnostic functions High resistance to abrasion Secondary process barrier
Supply voltage
4...20mA HART: 10,5...45V DC Ex ia: 10,5...30V DC PROFIBUS PA / FOUNDATION Fieldbus: 9...32V DC
Reference Accuracy
0,075% "PLATINUM" 0,05%
Long term stability
0,05% of URL/year 0,125% of URL/5 years
Process temperature
-20°C...85°C (-4°F...185°F)
Ambient temperature
-20°C...85°C (-4°F...185°F)
Measuring cell
100mbar...3bar (40inH2O...45psi)
Max. overpressure limit
on one side: 100 bar (1500psi)
Process connection
1/4-18NPT RC1/4" Flanges (DIN, ASME, JIS)
Communication
4...20mA HART PROFIBUS PA FOUNDATION Fieldbus
Certificates / Approvals
ATEX FM CSA NEPSI IECEx
Safety approvals
SIL WHG/ Overfill prevention
Design approvals
EN10204-3.1
Marine approvals
GL
Specialities
diagnostic functions
Successor
No direct successor. According to application FMD77 or PMC71.
Characteristic / Application
Digital transmitter with ceramic measuring diaphragms Modular transmitter Long term stability Enhanced safety via self diagnostic functions High resistance to abrasion Secondary process barrier
Supply / Communication
4...20 mA HART: 10,5...45V DC Ex ia: 10,5...30V DC PROFIBUS PA / FOUNDATION Fieldbus: 9...32V DC
Accuracy
0,075% "PLATINUM" 0,05%
Long term stability
0,05% of URL/year
Ambient temperature
-20°C...85°C (-4°F...185°F)
Process temperature
-20°C...85°C (-4°F...185°F)
Process pressure / max. overpressure limit
100bar (1500psi)
Pressure measuring range
100mbar...3bar (1.5psi...45 psi)
Main wetted parts
Ceramic Alloy C276 316L Monel Tantalum
Process connection
1/4-18NPT RC1/4" Flanges (DIN, ASME, JIS)
Max. measurement distance
30m (98ft) H2O
Communication
4...20 mA HART PROFIBUS PA FOUNDATION Fieldbus
Certificates / Approvals
ATEX FM CSA NEPSI IECEx SIL GL marine WHG/ Overfill prevention EN10204-3.1
Options
HistoROM/M-Dat 4-line digital display SS- or Aluminiumhousing Separate housing
Successor
No direct successor. According to application FMD77 or PMC71.