Oversigt over specifikationer
-
Max. measurement error
Mass flow (liquid): ±0.1 %
Volume flow (liquid): ±0.1 %
Mass flow (gas): ±0.35 % Density (liquid): ±0.0005 g/cm³ -
Measuring range
0 to 450 kg/h (0 to 16.54 lb/min)
-
Medium temperature range
-50 to 205 °C (-58 to 401 °F)
-
Max. process pressure
430.9 bar (6250 psi)
-
Wetted materials
Measuring tube: stainless steel, 1.4435 (316/316L); Alloy C22
Anvendelsesområde
The compact Promass A is ideal for continuous process control in very demanding applications. Its unique self-drainable single-tube system enables accurate measurement of liquids and gases at lowest flow rates and high pressure. With its innovative remote transmitter Promass A 500 maximizes installation flexibility and operational safety in demanding environments. Heartbeat Technology enables measurement reliability and compliant verification.
Measuring principle operates independently of physical fluid properties such as viscosity or density
Suitable for applications with smallest flow quantities in all industries
Device properties
Nominal diameter: DN 1 to 4 (¹⁄₂₄ to ¹⁄₈")
Process pressure up to 430.9 bar (6250 psi)
Medium temperature up to +205 °C (+401 °F)
Remote version with up to 4 I/Os
Backlit display with touch control and WLAN access
Standard cable between sensor and transmitter
Fordele
Space-saving installation – compact, lightweight sensor
Highest product quality – self-drainable measuring tube in all line sizes
Optimum process safety – resistant to corrosive ambient conditions and internal clogging
Full access to process and diagnostic information – numerous, freely combinable I/Os and Ethernet
Reduced complexity and variety – freely configurable I/O functionality
Integrated verification – Heartbeat Technology
Videoer
-
Standardprodukter
- Pålidelige og robuste med lav vedligeholdelse
Teknisk ydeevne
Enkelhed
-
Specialiserede produkter
- Designet til krævende applikationer
Teknisk ydeevne
Enkelhed
Variabel
FLEX valg | Teknisk ydeevne | Enkelhed |
---|---|---|
Fundamental Få dækket dine basale målebehov |
Teknisk ydeevne
|
Enkelhed
|
Lean Administrer nemt dine kerneprocesser |
Teknisk ydeevne
|
Enkelhed
|
Extended Optimer dine processer med innovative teknologier |
Teknisk ydeevne
|
Enkelhed
|
Xpert Til de mest udfordrende applikationer |
Teknisk ydeevne
|
Enkelhed
Variabel |
Forgænger
-
-
Tekniske oplysninger (TI)
Proline Promass A 500
Coriolis flowmeter
EN DA 01/08/202201/09/202016/09/201915/07/201901/11/2018Sprog:
Engelsk
Version:
01/08/2022
Filstørrelse:
11.3 MB
Filnavn:
TI01375DEN_0622-00.pdf
-
-
-
Betjeningsvejledning (BA)
Proline Promass A 500
Coriolis flowmeter
HARTEN DA 01/08/202201/09/202001/09/201901/08/2018Sprog:
Engelsk
Version:
01/08/2022
Filstørrelse:
9.5 MB
Filnavn:
BA01817DEN_0422-00.pdf
-
-
-
Betjeningsvejledning (BA)
Proline Promass A 500 EtherNet/IP
Coriolis flowmeter
EN DA 01/09/202001/08/2018Sprog:
Engelsk
Version:
01/09/2020
Filstørrelse:
9.7 MB
Filnavn:
BA01885DEN_0220.pdf
-
-
-
Betjeningsvejledning (BA)
Proline Promass A 500 PROFIBUS PA
Coriolis flowmeter
EN DA 01/09/202001/11/201801/08/2018Sprog:
Engelsk
Version:
01/09/2020
Filstørrelse:
8.2 MB
Filnavn:
BA01869DEN_0320.pdf
-
-
-
Betjeningsvejledning (BA)
Proline Promass A 500 PROFINET
Coriolis flowmeter
EN DA 01/09/202016/09/201915/07/201901/08/2018Sprog:
Engelsk
Version:
01/09/2020
Filstørrelse:
11.7 MB
Filnavn:
BA01886DEN_0420.pdf
-
-
-
Betjeningsvejledning (BA)
Proline Promass A 500 FOUNDATION Fieldbus
Coriolis flowmeter
EN DA 01/09/202001/08/2018Sprog:
Engelsk
Version:
01/09/2020
Filstørrelse:
7.9 MB
Filnavn:
BA01883DEN_0220.pdf
-
-
-
Betjeningsvejledning (BA)
Proline Promass A 500
Coriolis flowmeter
Modbus RS485EN DA 01/08/202201/09/202001/09/201901/08/2018Sprog:
Engelsk
Version:
01/08/2022
Filstørrelse:
9 MB
Filnavn:
BA01884DEN_0422-00.pdf
-
-
-
Betjeningsvejledning (BA)
Proline Promass A 500 PROFIBUS DP
Coriolis flowmeter
EN DA 01/09/202001/06/2018Sprog:
Engelsk
Version:
01/09/2020
Filstørrelse:
8 MB
Filnavn:
BA01870DEN_0220.pdf
-
-
-
Betjeningsvejledning (BA)
BA Proline Promass A 500
Coriolis flowmeter
PROFINET with Ethernet-APLEN DA 08/01/2024Sprog:
Engelsk
Version:
08/01/2024
Filstørrelse:
9.4 MB
Filnavn:
BA02121DEN_0122-00.pdf
-
-
-
Enhedsparameter (GP)
Proline Promass 500 EtherNet/IP Description of Device Parameters
Coriolis flowmeter
EN DA 01/08/201802/10/2017Sprog:
Engelsk
Version:
01/08/2018
Filstørrelse:
1.9 MB
Filnavn:
GP01120DEN_0218.pdf
-