Omnigrad M TR47

Produktbillede af: Omnigrad M TR47

Dette produkt er ikke længere tilgængeligt.

Se den nye generation i afsnittet med forgængere/efterfølgere, eller kontakt den lokale Endress+Hauser-afdeling.

Funktioner og specifikationer

Tilbage

Details

  • Measuring principle

    Resistance Temperature Detector

  • Characteristic / Application

    metric style

    modular temperature assembly

    hygienic design

    hygienic process connection

    with neck

    incl. thermowell / protection tube (metal)

  • Terminal head

    TA20A - aluminium - cover with screws

    TA20B - plastics - screw cover

    TA20D - aluminium - hinged cover high

    TA20J - SS - deep-drawn w. or w/o. display

    TA20R - SS - machined w. screw cover

    TA20W - aluminium - cover w. snap fit

    TA21E - aluminium - screw cover w. chain

  • Thermowell / protection tube

    bar stock (drilled)

  • Insert / probe

    mineral insulated (MI), flexible

  • Outer diameter protection tube / Insert

    3,00 mm ...13,00 mm

    (0,12'' ...0,51'')

  • Max. immersion length on request

    up to 600,00 mm (23,62'')

  • Material protection tube/ thermowell

    1.4435 (316L)

  • Optional coating

    Tantal

  • Process connection

    weld in version

    hygienic:

    welded (cylindircal)

    welded (spherical)

  • Tip shape

    reduced

  • Surface roughness Ra

    0,4 μm (15,7 μin.)

    0,8 μm (31,5 μin.)

  • Operating temperature range

    PT 100:

    -50 °C ...250 °C

    (-58 °F ...482 °F)

  • Max. process pressure (static)

    at 20 °C: 170 bar (2.466 psi)

  • Accuracy

    class A acc. to IEC 60751

    1/3 DIN class B acc. to IEC 60751

  • Response time

    depending on configuration

    t50 = 4 s

    t90 = 11 s

  • Integration head transmitter

    yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)

  • Ex - approvals

    ATEX II

    NEPSI

    IECEx

  • Certification

    Gost Metrology

    FDA

    3A

    SIL (transmitter only)

Dokumenter / Vejledninger / Software

Tilbehør / Reservedele

Nr
Order code
Specification
    • Order code 71249291

      Thermo-conductive paste FDA-conform 30g

    • Order code 71367406

      Spare parts kit copper ring G3/8",(10 p)

      Packing unit: 10 pieces

    • Order code 71111513

      Term.block DIN B (42mm) 3 term. 5 pc

    • Order code 71111514

      Term.block DIN B (42mm) 4 term. 5 pc

    • Order code 71111515

      Term.block DIN B (42mm) 6 term. 5 pc

    • Order code 71044061

      Fixing kit cpl.TMT82/85/84 (european)

      2x screws, 2x springs, 2x spring rings, 1x sealing CDI-connector

    • Order code 71163501

      Gasket ring D21/di10x2 Aramid+NBR

    • Order code 52028179

      Gasket 67.5x2.9x1.5 VMQ/PTFE, 5 pieces

      Profile gasket cover. Usage: housing F15 stainless steel.

    • Order code 60017971

      Display LC for TA20J

    • Order code 71043745

      Housing filter plastic F15, 3 pieces

      Consists of: filter plug plastic, Pressure compensation filter, O-ring. Usage: housing F15. Non Ex.

    • Order code TPR100-

      Insert TPR100

      Mineral insulated cable (MgO). Replaceable insert acc.EN60751. max. measuring range: -200...600oC (depending on configuration).

    • Order code TN15-

      Extension neck for thermowell TN15

      Neck tube made from welded parts, with thread connection to a terminal head form DIN B and different connections to a separate thermowell.

    • Order code TT411-

      iTHERM TT411 Thermowell

      Thermowell with hygienic design. Metrical version for applications in the food/beverages and pharmaceutical industries.

  • A
    • Nr A Order code TA20A-

      Terminal Head TA20A

      Product being phased out, limited availability. Connection head to mount a measuring insert with head transmitter or a connection socket. To be mounted on an armature or protective sleeve. Material: Aluminium epoxy resin coating Area temperature : max. +100 oC; ATEX: +95 oC.

    • Nr A Order code TA20B-

      Terminal Head TA20B

      "Product being phased out, limited availability." Connecting head to mount a measuring insert with head transmitter or a connection socket. To be mounted on an armature or protective sleeve. Material:Polyamid black. Ambient temperature: max. +80 oC. Protection: IP65.

    • Nr A Order code TA20D-

      Terminal head TA20D

      Product being phased out, limited availability. Connection head to mount a measuring insert with up to two head transmitters or a connection socket and one head transmitter. For mounting on armature or protection sleeve. Material: Aluminium, varnished Ambient temperature: max. +100 oC; ATEX: +95 oC. Protection: IP66

  • D
    • Nr D Order code TA20R-

      Terminal Head TA20R

      Product being phased out, limited availability. Connecting head to mount a measuring insert with head transmitter or a connection socket. To be mounted on an armature or protective sleeve. Material: AISI316L/1.4404. max temperature 100oC, ATEX: +95oC. Protection class IP66/IP67.

  • A
    • Nr A Order code TA20W-

      Terminal head TA20W

      Product being phased out, limited availability. Connection head hinged to mount a measuring insert with head transmitter or connection socket. To be mounted on an armature or a protection sleeve. Material: Aluminium Area temperature: max. +100 oC; ATEX: +95 oC Protection: IP66

    • Nr A Order code TA21E-

      Terminal Head TA21E

      Retainer for terminal block or head transmitter. Cover: srewable. Material: aluminum. Max. temp.: +100 oC; ATEX +95 oC. Protection: IP65.

  • C
    • Nr C Order code TMT82-

      iTEMP TMT82, Transmitter HART

      2-wire temperature transmitter. Dual universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. ::Highly reliable due to drift detection and sensor back up. ::Optional also for safety critical applications by means of SIL 2/3 acc. to IEC61508.

    • Nr C Order code TMT84-

      iTEMP TMT84, Transmitter PA

      Dual sensor input. Advanced diagnostics:sensor monitoring. PROFIBUS PA Profile 3.02. Galvanic isolation 2kV. Application: RTD, TC, Ohm, mV. Current consumption: 11 mA. Mounting: head form B, DIN EN50446. Factory setup: CH1: Pt100, 3-wire, oC. CH2: inactive. Differing configuration optional selectable.

    • Nr C Order code TMT85-

      iTEMP TMT85, Transmitter FF

      Dual sensor input. Advanced diagnostics: sensor monitoring. FOUNDATION Fieldbus protocol Galvanic isolation 2 kV. Application: RTC, TC, Ohm, mV. Current consumption: 11 mA. Mounting: head form B, DIN EN50446. Factory setup: CH1: Pt100, 3-wire, oC. CH2: inactive. Differing configuration optional selectable.

    • Nr C Order code TID10-

      Display for head transmitter TID10

      to plug on. Dot-Matrix measured value display. 12 DIP-switches buttom side. Settings: FF: Simulation, Write Lock. PA: Bus address, Write Lock. Compatible: TMT85, TMT84, TMT82.

    • Order code TXU10-

      Configuration kit TXU10-

      for PC-programmable devices. set-up programme+interface cable for PC with USB-Port.

    • Order code READWIN-

      Readwin 2000 Operation + Read. software

    • Order code FXA195-

      Commubox FXA195

      Modem to connect HART field devices to a computer via USB. Commissioning of field devices with software tool. :: To connect to a intrinsically safe signal circuit. :: SIL2, IEC61508.

  • A
    • Nr A Order code TA30A-

      Terminal Head TA30A

      Retainer for terminal block or head transmitter + optional display. Cover: low, hinged, optional window. Material: aluminium. Coating: polyester powder-coating. Colour: body blue, cover grey. Ambient temp.: -50...150 oC (housing). Protection: IP66/68, NEMA 4X (housing).

    • Nr A Order code TA30D-

      Terminal Head TA30D

      Retainer for 2 head transmitters or terminal blocks. Cover: high, hinged. Material: aluminium. Coating: polyester powder-coating. Colour: body blue, cover grey. Ambient temp.: -50...150 oC (housing). Protection: IP66/68, NEMA 4X (housing).

  • C
    • Nr C Order code TMT180-

      iTEMP TMT180, Head Transmitter Pt100

      Temperature transmitter,PC-programable. Application: RTD. 2-wire 4-20mA. Fault reaction: NAMUR NE 43. Mounting: head form B, DIN EN50446. UL listed.

    • Nr C Order code TMT181-

      iTEMP TMT181, Head Transmitter PCP

      Temperature transmitter,PC-programmable. Application: RTD, TC, Ohm, mV. 2-wire 4-20mA, galvanic isolation. Fault reaction: NAMUR NE 43. Mounting: head form B, DIN EN50446. UL listed.

    • Nr C Order code TMT182-

      iTEMP TMT182, Head Transmitter HART

      Temperature transmitter, Protocol HART. Application: RTD, TC, Ohm, mV. 2-wire 4-20mA, galvanicisolation. Fault reaction: NAMUR NE 43. Mounting: head form B, DIN EN50446. UL listed.

  • Afløser