Vibronic
Point level detection
Liquiphant FTL51

Liquiphant FTL51 ©Endress+Hauser
Liquiphant FTL51 ©Endress+Hauser

Vibronic measuring principle

Liquiphant with permanent function check is the safe choice for point level detection in liquids

Point level switch with extension tube for liquids in all industries

Liquiphant FTL51 is a point level switch with extension tube for use in hazardous areas with all international certificates. Useable in all industries. FTL51 offers functional safety SIL2/SIL3. With the second line of defense highest degree of safety and availability of the device can be guaranteed. Reliable measurement values, not affected by: changing media properties, flow, turbulences, gas bubbles, foam, vibrations or build-up.

  • Fordele

    • Use in safety systems requiring functional safety to SIL2/SIL3 in accordance with
      IEC 61508/IEC 61511-1

    • International explosion protection certificates and overfill prevention certificate (WHG)

    • No calibration required, easy to start up

    • No mechanically...

  • Anvendelsesområde

    Point level switch with extension tube for all liquids.

    • Process connections: Threads, flanges and hygienic process connection (Tri-Clamp)

    • Temperature: -50 to +150°C (-58 to +302°F)

    • Pressure: -1 to +100bar (-14.5 to +1,450psi)

    • Sensor material: 316L, Alloy

    • International explosion...